Infection and migration incidence of cardiac implantable electrical devices in Japan: Web‐based survey results
Abstract Web‐based survey was conducted for experiences of cardiac implantable electrical device (CIED) infection and migration in Japan. A total of 155 cardiologists’ answer was collected in January, 2018. CIED includes pacemaker (PM), implantable cardioverter defibrillator (ICD), cardiac resynchro...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2020-08-01
|
Series: | Journal of Arrhythmia |
Subjects: | |
Online Access: | https://doi.org/10.1002/joa3.12345 |
id |
doaj-cba18d9a714a46399b7b5e755980cd85 |
---|---|
record_format |
Article |
spelling |
doaj-cba18d9a714a46399b7b5e755980cd852020-11-25T03:18:46ZengWileyJournal of Arrhythmia1880-42761883-21482020-08-0136478078310.1002/joa3.12345Infection and migration incidence of cardiac implantable electrical devices in Japan: Web‐based survey resultsHiroshi Nakajima0Nobuhiro Nishii1Chiba‐Nishi General Hospital Matsudo JapanOkayama University Hospital Okayama JapanAbstract Web‐based survey was conducted for experiences of cardiac implantable electrical device (CIED) infection and migration in Japan. A total of 155 cardiologists’ answer was collected in January, 2018. CIED includes pacemaker (PM), implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy pacemaker (CRT‐P), and cardiac resynchronization therapy ICD (CRT‐D) and total of 10,499 CIEDs’ experiences of within previous twelve months were reported. CIED includes pacemaker (PM), implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy pacemaker (CRT‐P), and cardiac resynchronization therapy ICD (CRT‐D.). The infection rate of PM, ICD, CRT‐P, and CRT‐D was 0.79%, 0.81%, 0.45%, and 2.0%, respectively, and the device migration rate was 0.68%, 0.64%, 0.45%, and 0.93%, respectively. The overall infection rate was 0.85% and migration rate was 0.68%.https://doi.org/10.1002/joa3.12345CIEDsdevice migrationinfectionsurvey |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hiroshi Nakajima Nobuhiro Nishii |
spellingShingle |
Hiroshi Nakajima Nobuhiro Nishii Infection and migration incidence of cardiac implantable electrical devices in Japan: Web‐based survey results Journal of Arrhythmia CIEDs device migration infection survey |
author_facet |
Hiroshi Nakajima Nobuhiro Nishii |
author_sort |
Hiroshi Nakajima |
title |
Infection and migration incidence of cardiac implantable electrical devices in Japan: Web‐based survey results |
title_short |
Infection and migration incidence of cardiac implantable electrical devices in Japan: Web‐based survey results |
title_full |
Infection and migration incidence of cardiac implantable electrical devices in Japan: Web‐based survey results |
title_fullStr |
Infection and migration incidence of cardiac implantable electrical devices in Japan: Web‐based survey results |
title_full_unstemmed |
Infection and migration incidence of cardiac implantable electrical devices in Japan: Web‐based survey results |
title_sort |
infection and migration incidence of cardiac implantable electrical devices in japan: web‐based survey results |
publisher |
Wiley |
series |
Journal of Arrhythmia |
issn |
1880-4276 1883-2148 |
publishDate |
2020-08-01 |
description |
Abstract Web‐based survey was conducted for experiences of cardiac implantable electrical device (CIED) infection and migration in Japan. A total of 155 cardiologists’ answer was collected in January, 2018. CIED includes pacemaker (PM), implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy pacemaker (CRT‐P), and cardiac resynchronization therapy ICD (CRT‐D) and total of 10,499 CIEDs’ experiences of within previous twelve months were reported. CIED includes pacemaker (PM), implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy pacemaker (CRT‐P), and cardiac resynchronization therapy ICD (CRT‐D.). The infection rate of PM, ICD, CRT‐P, and CRT‐D was 0.79%, 0.81%, 0.45%, and 2.0%, respectively, and the device migration rate was 0.68%, 0.64%, 0.45%, and 0.93%, respectively. The overall infection rate was 0.85% and migration rate was 0.68%. |
topic |
CIEDs device migration infection survey |
url |
https://doi.org/10.1002/joa3.12345 |
work_keys_str_mv |
AT hiroshinakajima infectionandmigrationincidenceofcardiacimplantableelectricaldevicesinjapanwebbasedsurveyresults AT nobuhironishii infectionandmigrationincidenceofcardiacimplantableelectricaldevicesinjapanwebbasedsurveyresults |
_version_ |
1724625952571392000 |