Predictive parameters in hypofractionated whole-breast 3D conformal radiotherapy according to the Ontario Canadian trial

Grazia Lazzari,1 Angela Terlizzi,2 Giuseppina Della Vittoria Scarpati,3 Francesco Perri,3 Vincenzo De Chiara,4 Barbara Turi,1 Giovanni Silvano1 1Radiation Oncology Unit, 2Physics Department, 3Medical Oncology Unit, Saint Giuseppe Moscati Hospital, 4Radiation Therapy Unit, Saints Giovanni Di Dio and...

Full description

Bibliographic Details
Main Authors: Lazzari G, Terlizzi A, Della Vittoria Scarpati G, Perri F, De Chiara V, Turi B, Silvano G
Format: Article
Language:English
Published: Dove Medical Press 2017-03-01
Series:OncoTargets and Therapy
Subjects:
Online Access:https://www.dovepress.com/predictive-parameters-in-hypofractionated-whole-breast-3d-conformal-ra-peer-reviewed-article-OTT
id doaj-ca7761cc574f46e7800a2873ce031c7e
record_format Article
spelling doaj-ca7761cc574f46e7800a2873ce031c7e2020-11-24T23:02:11ZengDove Medical PressOncoTargets and Therapy1178-69302017-03-01Volume 101835184232039Predictive parameters in hypofractionated whole-breast 3D conformal radiotherapy according to the Ontario Canadian trialLazzari GTerlizzi ADella Vittoria Scarpati GPerri FDe Chiara VTuri BSilvano GGrazia Lazzari,1 Angela Terlizzi,2 Giuseppina Della Vittoria Scarpati,3 Francesco Perri,3 Vincenzo De Chiara,4 Barbara Turi,1 Giovanni Silvano1 1Radiation Oncology Unit, 2Physics Department, 3Medical Oncology Unit, Saint Giuseppe Moscati Hospital, 4Radiation Therapy Unit, Saints Giovanni Di Dio and Ruggi di Aragona, University of Salerno, Taranto, Italy Aim: To evaluate the possible role of dosimetric parameters according Normal Tissue Complication Probability (NTCP) model as predictive of late toxicity and cosmesis in hypofractionated whole-breast three-dimensional conformal radiotherapy. Patients and methods: A retrospective analysis on 215 consecutive early breast cancer patients treated with breast conserving surgery and adjuvant hypofractionated whole-breast radiotherapy (according the Ontario Canadian trial), with a 6 years median follow-up was conducted. To assess the impact of 10%–20% dose hotspots on different percent values of planning target volume (PTV) of the breast, we retrospectively employed the NTCP model of Lyman. PTV breast (PTVbr), V110 were identified. For statistical analysis the χ2 and paired t-test were used to find a correlation between late skin and subcutaneous toxicity and cosmetic outcome with dosimetrical parameters Multivariate analysis was performed with the aim to assess independently the impact of dosimetric and clinical parameters on late toxicity and cosmesis using Pearson’s covariance. Results: Late skin toxicity was recorded in 47/215 (22%); and G3 toxicity occurred in 11 patients (5%). Cosmesis with excellent–good score was found in 172 patients (80%) while fair–poor score was found in 43 patients (20%). In univariate χ2 analysis the V110 >10% of the PTV breast significantly correlated with higher toxicity (P<0.005, OR 9.60 [CI 3.89–23.72]). Cosmesis related to V110 >10% and PTV breast volume over 1,300 cc was significant at multivariate analysis (P<0.005, OR 6.07 [CI 2.36–15.59]). Conclusion: To safely use one of the most important whole-breast hypofractionated radiotherapy schedules, we found some predictive paramaters on the basis of NTCP model by Lyman. These parameters may be useful in selection of elegible patients. Keywords: NTCP model, Ontario Canadian Trial, hypofractionated radiotherapy, whole-breast, cosmesis, toxicity, PTV breast, V110, early breast cancerhttps://www.dovepress.com/predictive-parameters-in-hypofractionated-whole-breast-3d-conformal-ra-peer-reviewed-article-OTTNTCP modelCanadian Trialhypofrationated radiotherapywhole breast
collection DOAJ
language English
format Article
sources DOAJ
author Lazzari G
Terlizzi A
Della Vittoria Scarpati G
Perri F
De Chiara V
Turi B
Silvano G
spellingShingle Lazzari G
Terlizzi A
Della Vittoria Scarpati G
Perri F
De Chiara V
Turi B
Silvano G
Predictive parameters in hypofractionated whole-breast 3D conformal radiotherapy according to the Ontario Canadian trial
OncoTargets and Therapy
NTCP model
Canadian Trial
hypofrationated radiotherapy
whole breast
author_facet Lazzari G
Terlizzi A
Della Vittoria Scarpati G
Perri F
De Chiara V
Turi B
Silvano G
author_sort Lazzari G
title Predictive parameters in hypofractionated whole-breast 3D conformal radiotherapy according to the Ontario Canadian trial
title_short Predictive parameters in hypofractionated whole-breast 3D conformal radiotherapy according to the Ontario Canadian trial
title_full Predictive parameters in hypofractionated whole-breast 3D conformal radiotherapy according to the Ontario Canadian trial
title_fullStr Predictive parameters in hypofractionated whole-breast 3D conformal radiotherapy according to the Ontario Canadian trial
title_full_unstemmed Predictive parameters in hypofractionated whole-breast 3D conformal radiotherapy according to the Ontario Canadian trial
title_sort predictive parameters in hypofractionated whole-breast 3d conformal radiotherapy according to the ontario canadian trial
publisher Dove Medical Press
series OncoTargets and Therapy
issn 1178-6930
publishDate 2017-03-01
description Grazia Lazzari,1 Angela Terlizzi,2 Giuseppina Della Vittoria Scarpati,3 Francesco Perri,3 Vincenzo De Chiara,4 Barbara Turi,1 Giovanni Silvano1 1Radiation Oncology Unit, 2Physics Department, 3Medical Oncology Unit, Saint Giuseppe Moscati Hospital, 4Radiation Therapy Unit, Saints Giovanni Di Dio and Ruggi di Aragona, University of Salerno, Taranto, Italy Aim: To evaluate the possible role of dosimetric parameters according Normal Tissue Complication Probability (NTCP) model as predictive of late toxicity and cosmesis in hypofractionated whole-breast three-dimensional conformal radiotherapy. Patients and methods: A retrospective analysis on 215 consecutive early breast cancer patients treated with breast conserving surgery and adjuvant hypofractionated whole-breast radiotherapy (according the Ontario Canadian trial), with a 6 years median follow-up was conducted. To assess the impact of 10%–20% dose hotspots on different percent values of planning target volume (PTV) of the breast, we retrospectively employed the NTCP model of Lyman. PTV breast (PTVbr), V110 were identified. For statistical analysis the χ2 and paired t-test were used to find a correlation between late skin and subcutaneous toxicity and cosmetic outcome with dosimetrical parameters Multivariate analysis was performed with the aim to assess independently the impact of dosimetric and clinical parameters on late toxicity and cosmesis using Pearson’s covariance. Results: Late skin toxicity was recorded in 47/215 (22%); and G3 toxicity occurred in 11 patients (5%). Cosmesis with excellent–good score was found in 172 patients (80%) while fair–poor score was found in 43 patients (20%). In univariate χ2 analysis the V110 >10% of the PTV breast significantly correlated with higher toxicity (P<0.005, OR 9.60 [CI 3.89–23.72]). Cosmesis related to V110 >10% and PTV breast volume over 1,300 cc was significant at multivariate analysis (P<0.005, OR 6.07 [CI 2.36–15.59]). Conclusion: To safely use one of the most important whole-breast hypofractionated radiotherapy schedules, we found some predictive paramaters on the basis of NTCP model by Lyman. These parameters may be useful in selection of elegible patients. Keywords: NTCP model, Ontario Canadian Trial, hypofractionated radiotherapy, whole-breast, cosmesis, toxicity, PTV breast, V110, early breast cancer
topic NTCP model
Canadian Trial
hypofrationated radiotherapy
whole breast
url https://www.dovepress.com/predictive-parameters-in-hypofractionated-whole-breast-3d-conformal-ra-peer-reviewed-article-OTT
work_keys_str_mv AT lazzarig predictiveparametersinhypofractionatedwholebreast3dconformalradiotherapyaccordingtotheontariocanadiantrial
AT terlizzia predictiveparametersinhypofractionatedwholebreast3dconformalradiotherapyaccordingtotheontariocanadiantrial
AT dellavittoriascarpatig predictiveparametersinhypofractionatedwholebreast3dconformalradiotherapyaccordingtotheontariocanadiantrial
AT perrif predictiveparametersinhypofractionatedwholebreast3dconformalradiotherapyaccordingtotheontariocanadiantrial
AT dechiarav predictiveparametersinhypofractionatedwholebreast3dconformalradiotherapyaccordingtotheontariocanadiantrial
AT turib predictiveparametersinhypofractionatedwholebreast3dconformalradiotherapyaccordingtotheontariocanadiantrial
AT silvanog predictiveparametersinhypofractionatedwholebreast3dconformalradiotherapyaccordingtotheontariocanadiantrial
_version_ 1725637022411915264