Micropulse Trabeculoplasty in Open Angle Glaucoma

Background: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). Materials and Methods: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in...

Full description

Bibliographic Details
Main Authors: Diego Alejandro Valera-Cornejo, Waldo Loayza-Gamboa, Julio Herrera-Quiroz, Rosa Alvarado-Vlllacorta, Luis Cordova-Crisanto, Vanessa Valderrama-Albino, Nahuel Pantoja Davalos
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2018-01-01
Series:Advanced Biomedical Research
Subjects:
Online Access:http://www.advbiores.net/article.asp?issn=2277-9175;year=2018;volume=7;issue=1;spage=156;epage=156;aulast=Valera-Cornejo
id doaj-ca0190b786a84ceea0844c0dc9345737
record_format Article
spelling doaj-ca0190b786a84ceea0844c0dc93457372020-11-24T21:56:46ZengWolters Kluwer Medknow PublicationsAdvanced Biomedical Research2277-91752018-01-017115615610.4103/abr.abr_203_17Micropulse Trabeculoplasty in Open Angle GlaucomaDiego Alejandro Valera-CornejoWaldo Loayza-GamboaJulio Herrera-QuirozRosa Alvarado-VlllacortaLuis Cordova-CrisantoVanessa Valderrama-AlbinoNahuel Pantoja DavalosBackground: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). Materials and Methods: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in Lima Perú. We used a 532 nm frequency doubled Nd: YAG laser to 360° of the trabecular meshwork with a power of 1000 mW, 15% of the duty cycle, and 300 ms of exposure. The IOP was measured at baseline and at 1 day, 1 week, 3 months, and 6 months post-treatment and were followed up for one last control. Results: The mean baseline IOP was 15.6 mmHg and in the last control was 12.8 mmHg, mean follow-up time of 19 months (±10 standard deviation [SD]). The mean reduction of IOP in the 1st day was 1.6 mmHg (±2.6 SD) and 1.2 mmHg (±3.3 SD) in the last follow-up. The mean percentage of IOP reduction was 17.9% and 7 eyes (40%) had IOP reduction >20%. No statistical significant difference in relation to demographic characteristics of the patients. The greatest reduction was achieved in the 1st day with a median of 2.00 (P < 0.001). A tendency to achieve a higher reduction of IOP in patients with higher baseline IOP was found but was not statistically significant. No adverse reactions occurred. Conclusions: MLT slightly reduced the IOP in a few patients with uncontrolled OAG for a very short time and may not be suitable for these patients.http://www.advbiores.net/article.asp?issn=2277-9175;year=2018;volume=7;issue=1;spage=156;epage=156;aulast=Valera-CornejoDiode lasermicropulseopen angle glaucomasubthresholdtrabeculoplasty
collection DOAJ
language English
format Article
sources DOAJ
author Diego Alejandro Valera-Cornejo
Waldo Loayza-Gamboa
Julio Herrera-Quiroz
Rosa Alvarado-Vlllacorta
Luis Cordova-Crisanto
Vanessa Valderrama-Albino
Nahuel Pantoja Davalos
spellingShingle Diego Alejandro Valera-Cornejo
Waldo Loayza-Gamboa
Julio Herrera-Quiroz
Rosa Alvarado-Vlllacorta
Luis Cordova-Crisanto
Vanessa Valderrama-Albino
Nahuel Pantoja Davalos
Micropulse Trabeculoplasty in Open Angle Glaucoma
Advanced Biomedical Research
Diode laser
micropulse
open angle glaucoma
subthreshold
trabeculoplasty
author_facet Diego Alejandro Valera-Cornejo
Waldo Loayza-Gamboa
Julio Herrera-Quiroz
Rosa Alvarado-Vlllacorta
Luis Cordova-Crisanto
Vanessa Valderrama-Albino
Nahuel Pantoja Davalos
author_sort Diego Alejandro Valera-Cornejo
title Micropulse Trabeculoplasty in Open Angle Glaucoma
title_short Micropulse Trabeculoplasty in Open Angle Glaucoma
title_full Micropulse Trabeculoplasty in Open Angle Glaucoma
title_fullStr Micropulse Trabeculoplasty in Open Angle Glaucoma
title_full_unstemmed Micropulse Trabeculoplasty in Open Angle Glaucoma
title_sort micropulse trabeculoplasty in open angle glaucoma
publisher Wolters Kluwer Medknow Publications
series Advanced Biomedical Research
issn 2277-9175
publishDate 2018-01-01
description Background: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). Materials and Methods: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in Lima Perú. We used a 532 nm frequency doubled Nd: YAG laser to 360° of the trabecular meshwork with a power of 1000 mW, 15% of the duty cycle, and 300 ms of exposure. The IOP was measured at baseline and at 1 day, 1 week, 3 months, and 6 months post-treatment and were followed up for one last control. Results: The mean baseline IOP was 15.6 mmHg and in the last control was 12.8 mmHg, mean follow-up time of 19 months (±10 standard deviation [SD]). The mean reduction of IOP in the 1st day was 1.6 mmHg (±2.6 SD) and 1.2 mmHg (±3.3 SD) in the last follow-up. The mean percentage of IOP reduction was 17.9% and 7 eyes (40%) had IOP reduction >20%. No statistical significant difference in relation to demographic characteristics of the patients. The greatest reduction was achieved in the 1st day with a median of 2.00 (P < 0.001). A tendency to achieve a higher reduction of IOP in patients with higher baseline IOP was found but was not statistically significant. No adverse reactions occurred. Conclusions: MLT slightly reduced the IOP in a few patients with uncontrolled OAG for a very short time and may not be suitable for these patients.
topic Diode laser
micropulse
open angle glaucoma
subthreshold
trabeculoplasty
url http://www.advbiores.net/article.asp?issn=2277-9175;year=2018;volume=7;issue=1;spage=156;epage=156;aulast=Valera-Cornejo
work_keys_str_mv AT diegoalejandrovaleracornejo micropulsetrabeculoplastyinopenangleglaucoma
AT waldoloayzagamboa micropulsetrabeculoplastyinopenangleglaucoma
AT julioherreraquiroz micropulsetrabeculoplastyinopenangleglaucoma
AT rosaalvaradovlllacorta micropulsetrabeculoplastyinopenangleglaucoma
AT luiscordovacrisanto micropulsetrabeculoplastyinopenangleglaucoma
AT vanessavalderramaalbino micropulsetrabeculoplastyinopenangleglaucoma
AT nahuelpantojadavalos micropulsetrabeculoplastyinopenangleglaucoma
_version_ 1725857166500298752