Micropulse Trabeculoplasty in Open Angle Glaucoma
Background: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). Materials and Methods: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2018-01-01
|
Series: | Advanced Biomedical Research |
Subjects: | |
Online Access: | http://www.advbiores.net/article.asp?issn=2277-9175;year=2018;volume=7;issue=1;spage=156;epage=156;aulast=Valera-Cornejo |
id |
doaj-ca0190b786a84ceea0844c0dc9345737 |
---|---|
record_format |
Article |
spelling |
doaj-ca0190b786a84ceea0844c0dc93457372020-11-24T21:56:46ZengWolters Kluwer Medknow PublicationsAdvanced Biomedical Research2277-91752018-01-017115615610.4103/abr.abr_203_17Micropulse Trabeculoplasty in Open Angle GlaucomaDiego Alejandro Valera-CornejoWaldo Loayza-GamboaJulio Herrera-QuirozRosa Alvarado-VlllacortaLuis Cordova-CrisantoVanessa Valderrama-AlbinoNahuel Pantoja DavalosBackground: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). Materials and Methods: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in Lima Perú. We used a 532 nm frequency doubled Nd: YAG laser to 360° of the trabecular meshwork with a power of 1000 mW, 15% of the duty cycle, and 300 ms of exposure. The IOP was measured at baseline and at 1 day, 1 week, 3 months, and 6 months post-treatment and were followed up for one last control. Results: The mean baseline IOP was 15.6 mmHg and in the last control was 12.8 mmHg, mean follow-up time of 19 months (±10 standard deviation [SD]). The mean reduction of IOP in the 1st day was 1.6 mmHg (±2.6 SD) and 1.2 mmHg (±3.3 SD) in the last follow-up. The mean percentage of IOP reduction was 17.9% and 7 eyes (40%) had IOP reduction >20%. No statistical significant difference in relation to demographic characteristics of the patients. The greatest reduction was achieved in the 1st day with a median of 2.00 (P < 0.001). A tendency to achieve a higher reduction of IOP in patients with higher baseline IOP was found but was not statistically significant. No adverse reactions occurred. Conclusions: MLT slightly reduced the IOP in a few patients with uncontrolled OAG for a very short time and may not be suitable for these patients.http://www.advbiores.net/article.asp?issn=2277-9175;year=2018;volume=7;issue=1;spage=156;epage=156;aulast=Valera-CornejoDiode lasermicropulseopen angle glaucomasubthresholdtrabeculoplasty |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Diego Alejandro Valera-Cornejo Waldo Loayza-Gamboa Julio Herrera-Quiroz Rosa Alvarado-Vlllacorta Luis Cordova-Crisanto Vanessa Valderrama-Albino Nahuel Pantoja Davalos |
spellingShingle |
Diego Alejandro Valera-Cornejo Waldo Loayza-Gamboa Julio Herrera-Quiroz Rosa Alvarado-Vlllacorta Luis Cordova-Crisanto Vanessa Valderrama-Albino Nahuel Pantoja Davalos Micropulse Trabeculoplasty in Open Angle Glaucoma Advanced Biomedical Research Diode laser micropulse open angle glaucoma subthreshold trabeculoplasty |
author_facet |
Diego Alejandro Valera-Cornejo Waldo Loayza-Gamboa Julio Herrera-Quiroz Rosa Alvarado-Vlllacorta Luis Cordova-Crisanto Vanessa Valderrama-Albino Nahuel Pantoja Davalos |
author_sort |
Diego Alejandro Valera-Cornejo |
title |
Micropulse Trabeculoplasty in Open Angle Glaucoma |
title_short |
Micropulse Trabeculoplasty in Open Angle Glaucoma |
title_full |
Micropulse Trabeculoplasty in Open Angle Glaucoma |
title_fullStr |
Micropulse Trabeculoplasty in Open Angle Glaucoma |
title_full_unstemmed |
Micropulse Trabeculoplasty in Open Angle Glaucoma |
title_sort |
micropulse trabeculoplasty in open angle glaucoma |
publisher |
Wolters Kluwer Medknow Publications |
series |
Advanced Biomedical Research |
issn |
2277-9175 |
publishDate |
2018-01-01 |
description |
Background: We report the effect of micropulse laser trabeculoplasty (MLT) in the intraocular pressure (IOP) of patients with uncontrolled open-angle glaucoma (OAG). Materials and Methods: In this retrospective review, 30 eyes with OAG were treated with a single session of MLT at the Vista Clinic in Lima Perú. We used a 532 nm frequency doubled Nd: YAG laser to 360° of the trabecular meshwork with a power of 1000 mW, 15% of the duty cycle, and 300 ms of exposure. The IOP was measured at baseline and at 1 day, 1 week, 3 months, and 6 months post-treatment and were followed up for one last control. Results: The mean baseline IOP was 15.6 mmHg and in the last control was 12.8 mmHg, mean follow-up time of 19 months (±10 standard deviation [SD]). The mean reduction of IOP in the 1st day was 1.6 mmHg (±2.6 SD) and 1.2 mmHg (±3.3 SD) in the last follow-up. The mean percentage of IOP reduction was 17.9% and 7 eyes (40%) had IOP reduction >20%. No statistical significant difference in relation to demographic characteristics of the patients. The greatest reduction was achieved in the 1st day with a median of 2.00 (P < 0.001). A tendency to achieve a higher reduction of IOP in patients with higher baseline IOP was found but was not statistically significant. No adverse reactions occurred. Conclusions: MLT slightly reduced the IOP in a few patients with uncontrolled OAG for a very short time and may not be suitable for these patients. |
topic |
Diode laser micropulse open angle glaucoma subthreshold trabeculoplasty |
url |
http://www.advbiores.net/article.asp?issn=2277-9175;year=2018;volume=7;issue=1;spage=156;epage=156;aulast=Valera-Cornejo |
work_keys_str_mv |
AT diegoalejandrovaleracornejo micropulsetrabeculoplastyinopenangleglaucoma AT waldoloayzagamboa micropulsetrabeculoplastyinopenangleglaucoma AT julioherreraquiroz micropulsetrabeculoplastyinopenangleglaucoma AT rosaalvaradovlllacorta micropulsetrabeculoplastyinopenangleglaucoma AT luiscordovacrisanto micropulsetrabeculoplastyinopenangleglaucoma AT vanessavalderramaalbino micropulsetrabeculoplastyinopenangleglaucoma AT nahuelpantojadavalos micropulsetrabeculoplastyinopenangleglaucoma |
_version_ |
1725857166500298752 |