Inâ€situ investigation of concentration of strains around an implanted bar

For constructional purposes reinforcement bars or connecting elements (implants) of a stronger material are installed in concrete, plastic, timber or another similar materialâ€matrix. Structural concepts are being developed where implants are used both as reinforcing and connecting elements. The im...

Full description

Bibliographic Details
Main Authors: Valerijus Keras, Jonas RoliÄius
Format: Article
Language:English
Published: Vilnius Gediminas Technical University 2005-03-01
Series:Journal of Civil Engineering and Management
Subjects:
Online Access:http://localhost/journals.vgtu.lt/index.php/JCEM/article/view/8891
id doaj-c97b3d1b8f3945669142a5d11d4026e8
record_format Article
spelling doaj-c97b3d1b8f3945669142a5d11d4026e82021-07-02T15:17:55ZengVilnius Gediminas Technical UniversityJournal of Civil Engineering and Management1392-37301822-36052005-03-0111110.3846/13923730.2005.9636331Inâ€situ investigation of concentration of strains around an implanted barValerijus Keras0Jonas RoliÄius1Dept of Building Structures , Kaunas University of Technology , Studentu g. 48, Kaunas, LTâ€51367, LithuaniaDept of Civil Engineering , University of Å iauliai , Vilniaus g. 141, Å iauliai, LTâ€76353, Lithuania For constructional purposes reinforcement bars or connecting elements (implants) of a stronger material are installed in concrete, plastic, timber or another similar materialâ€matrix. Structural concepts are being developed where implants are used both as reinforcing and connecting elements. The implants increase the strength and rigidity of structures. However, investigation of functioning of implants and generalisation of data obtained up to now have been premature. Moreover, they do not help us to understand some empiric facts. In the course of the aboveâ€mentioned tests (data concerning the tests were presented in previously published works), steel barsâ€implants with one meter thread were screwed and glued into timber and then attempts to extract them were made. During the test, the bars were screwed into holes in the timber filled with glue. The angle at which the implant was screwed through the layers of wood, the type of glue and some other factors were changed. Such characteristics as strength, strain, breakage and the process of deformation were analysed. Deformainijų koncentracijos implantuoto strypo aplinkoje ir jų natÅ«riniai tyrimai Santrauka Betonuose, plastike, medienoje ar panaÅ¡ioje medžiagoje †matricoje konstrukciniais sumetimais dažnai yra įterpiami stipresnÄ—s medžiagos strypai †armuojantys implantai. Tobulinami inžineriniai kompleksinio implantų naudojimo sprendimai, kai jie naudojami ir kaip armavimo, ir kaip jungimo priemonÄ—s. TaÄiau iki Å¡iol sukaupti implantų darbo tyrimu duomenys nÄ—ra iÅ¡samÅ«s, jų apibendrinimai †kiek skuboti. TÄ™siant Å¡iuos tyrimus, buvo bandomi įsriegti ir įklijuoti ar tik įklijuoti į puÅ¡inÄ™ medienÄ… stambieji metrinio sriegio strypaiâ€implantai. Buvo keiÄiamas implanto su medienos sluoksniais sudaromas kampas, klijų pobÅ«dis, kiti veiksniai. Buvo apraÅ¡ytos stiprumo, deformatyvumo, irimo charakteristikos, nagrinÄ—tų procesu pobÅ«dis. PasiÅ«lytos empirinÄ—s pareinamybÄ—s: vidutinÄ—, gauta, remiantis bandymų duomenimis, techniÅ¡kai patikima Å¡ių duomenų aibÄ—je ir pan. Raktiniai žodžiai: mediena, implantai, klijai, stiprumas, deformatyvumas, irimas. First Published Online: 14 Oct 2010 http://localhost/journals.vgtu.lt/index.php/JCEM/article/view/8891timberimplantsglueglulamstrengthstrain
collection DOAJ
language English
format Article
sources DOAJ
author Valerijus Keras
Jonas RoliÄius
spellingShingle Valerijus Keras
Jonas RoliÄius
Inâ€situ investigation of concentration of strains around an implanted bar
Journal of Civil Engineering and Management
timber
implants
glue
glulam
strength
strain
author_facet Valerijus Keras
Jonas RoliÄius
author_sort Valerijus Keras
title Inâ€situ investigation of concentration of strains around an implanted bar
title_short Inâ€situ investigation of concentration of strains around an implanted bar
title_full Inâ€situ investigation of concentration of strains around an implanted bar
title_fullStr Inâ€situ investigation of concentration of strains around an implanted bar
title_full_unstemmed Inâ€situ investigation of concentration of strains around an implanted bar
title_sort inâ€situ investigation of concentration of strains around an implanted bar
publisher Vilnius Gediminas Technical University
series Journal of Civil Engineering and Management
issn 1392-3730
1822-3605
publishDate 2005-03-01
description For constructional purposes reinforcement bars or connecting elements (implants) of a stronger material are installed in concrete, plastic, timber or another similar materialâ€matrix. Structural concepts are being developed where implants are used both as reinforcing and connecting elements. The implants increase the strength and rigidity of structures. However, investigation of functioning of implants and generalisation of data obtained up to now have been premature. Moreover, they do not help us to understand some empiric facts. In the course of the aboveâ€mentioned tests (data concerning the tests were presented in previously published works), steel barsâ€implants with one meter thread were screwed and glued into timber and then attempts to extract them were made. During the test, the bars were screwed into holes in the timber filled with glue. The angle at which the implant was screwed through the layers of wood, the type of glue and some other factors were changed. Such characteristics as strength, strain, breakage and the process of deformation were analysed. Deformainijų koncentracijos implantuoto strypo aplinkoje ir jų natÅ«riniai tyrimai Santrauka Betonuose, plastike, medienoje ar panaÅ¡ioje medžiagoje †matricoje konstrukciniais sumetimais dažnai yra įterpiami stipresnÄ—s medžiagos strypai †armuojantys implantai. Tobulinami inžineriniai kompleksinio implantų naudojimo sprendimai, kai jie naudojami ir kaip armavimo, ir kaip jungimo priemonÄ—s. TaÄiau iki Å¡iol sukaupti implantų darbo tyrimu duomenys nÄ—ra iÅ¡samÅ«s, jų apibendrinimai †kiek skuboti. TÄ™siant Å¡iuos tyrimus, buvo bandomi įsriegti ir įklijuoti ar tik įklijuoti į puÅ¡inÄ™ medienÄ… stambieji metrinio sriegio strypaiâ€implantai. Buvo keiÄiamas implanto su medienos sluoksniais sudaromas kampas, klijų pobÅ«dis, kiti veiksniai. Buvo apraÅ¡ytos stiprumo, deformatyvumo, irimo charakteristikos, nagrinÄ—tų procesu pobÅ«dis. PasiÅ«lytos empirinÄ—s pareinamybÄ—s: vidutinÄ—, gauta, remiantis bandymų duomenimis, techniÅ¡kai patikima Å¡ių duomenų aibÄ—je ir pan. Raktiniai žodžiai: mediena, implantai, klijai, stiprumas, deformatyvumas, irimas. First Published Online: 14 Oct 2010
topic timber
implants
glue
glulam
strength
strain
url http://localhost/journals.vgtu.lt/index.php/JCEM/article/view/8891
work_keys_str_mv AT valerijuskeras inasituinvestigationofconcentrationofstrainsaroundanimplantedbar
AT jonasroliaius inasituinvestigationofconcentrationofstrainsaroundanimplantedbar
_version_ 1721327272163540992