Sistem Deteksi Petir Multistation Dengan Metode Time of Arrival

This study was done at ligtning detection system in Padang. The systems was consist of 3 electric field sensors with synchronous satelite GPS. Time of arrival and sensors coordinate was taken from each sensors. This data was used to calculate ligtning location by Time of Arrival Linear Spherical met...

Full description

Bibliographic Details
Main Authors: Dasrinal Tessal, Primas Emeraldi, Ariadi Hazmi
Format: Article
Language:English
Published: Universitas Andalas 2015-03-01
Series:Jurnal Nasional Teknik Elektro
Subjects:
Online Access:http://jnte.ft.unand.ac.id/index.php/first/article/view/105/130
id doaj-c941f29b68bb444a9512279d6be86ee0
record_format Article
spelling doaj-c941f29b68bb444a9512279d6be86ee02021-07-02T15:34:57ZengUniversitas AndalasJurnal Nasional Teknik Elektro2302-29492407-72672015-03-01411321Sistem Deteksi Petir Multistation Dengan Metode Time of ArrivalDasrinal Tessal0Primas Emeraldi1Ariadi Hazmi2Mahasiswa S2 Teknik Elektro, Universitas AndalasJurusan Teknik Elektro, Universitas AndalasJurusan Teknik Elektro, Universitas AndalasThis study was done at ligtning detection system in Padang. The systems was consist of 3 electric field sensors with synchronous satelite GPS. Time of arrival and sensors coordinate was taken from each sensors. This data was used to calculate ligtning location by Time of Arrival Linear Spherical method. Then the distances between lighting and sensor can be calculated. The distances will compared with electric field waveforms recorded at lightning sensor to testing validity our results. After validity, lightning current peak can be calculated. 8 of 20 data sample are valid with lowest lightning current peak is -1,001 kA dan highest value is -2,661 kA. http://jnte.ft.unand.ac.id/index.php/first/article/view/105/130LightningLightning Detection SystemTime of Arrival Ligtning Current Peak
collection DOAJ
language English
format Article
sources DOAJ
author Dasrinal Tessal
Primas Emeraldi
Ariadi Hazmi
spellingShingle Dasrinal Tessal
Primas Emeraldi
Ariadi Hazmi
Sistem Deteksi Petir Multistation Dengan Metode Time of Arrival
Jurnal Nasional Teknik Elektro
Lightning
Lightning Detection System
Time of Arrival Ligtning Current Peak
author_facet Dasrinal Tessal
Primas Emeraldi
Ariadi Hazmi
author_sort Dasrinal Tessal
title Sistem Deteksi Petir Multistation Dengan Metode Time of Arrival
title_short Sistem Deteksi Petir Multistation Dengan Metode Time of Arrival
title_full Sistem Deteksi Petir Multistation Dengan Metode Time of Arrival
title_fullStr Sistem Deteksi Petir Multistation Dengan Metode Time of Arrival
title_full_unstemmed Sistem Deteksi Petir Multistation Dengan Metode Time of Arrival
title_sort sistem deteksi petir multistation dengan metode time of arrival
publisher Universitas Andalas
series Jurnal Nasional Teknik Elektro
issn 2302-2949
2407-7267
publishDate 2015-03-01
description This study was done at ligtning detection system in Padang. The systems was consist of 3 electric field sensors with synchronous satelite GPS. Time of arrival and sensors coordinate was taken from each sensors. This data was used to calculate ligtning location by Time of Arrival Linear Spherical method. Then the distances between lighting and sensor can be calculated. The distances will compared with electric field waveforms recorded at lightning sensor to testing validity our results. After validity, lightning current peak can be calculated. 8 of 20 data sample are valid with lowest lightning current peak is -1,001 kA dan highest value is -2,661 kA.
topic Lightning
Lightning Detection System
Time of Arrival Ligtning Current Peak
url http://jnte.ft.unand.ac.id/index.php/first/article/view/105/130
work_keys_str_mv AT dasrinaltessal sistemdeteksipetirmultistationdenganmetodetimeofarrival
AT primasemeraldi sistemdeteksipetirmultistationdenganmetodetimeofarrival
AT ariadihazmi sistemdeteksipetirmultistationdenganmetodetimeofarrival
_version_ 1721327157681061888