Summary: | In this study, various diagnostic tools were constructed and plasma factors measured to evaluate the intelligence of plasma process equipment. We used an ICP (Inductively Coupled Plasma) reactor with a radio frequency (RF) power of 13.56 MHz, a power of 400 to 800 W, and a pressure of 10 to 30 mTorr. Plasma parameters such as electron density (n<sub>e</sub>), electron temperature (T<sub>e</sub>), plasma potential (V<sub>p</sub>), and floating potential (V<sub>f</sub>) were measured using several instruments (VI probe and mass/energy analyzer, etc.) and subsequently analyzed. Regression analysis was performed to correlate the measured data with the plasma parameters. As a result, the plasma density (n<sub>e</sub>) and temperature (T<sub>e</sub>) were observed to be in good agreement with the non-invasive measurement results. In particular, the VI probes were highly correlated with almost all the measured plasma parameters. Therefore, the results of this study provide a basis for the estimation of plasma parameters using non-invasive measurement techniques.
|