Frequency Dependence of Receiving Sensitivity of Ultrasonic Transducers and Acoustic Emission Sensors

Receiving displacement sensitivities (Rx) of ultrasonic transducers and acoustic emission (AE) sensors are evaluated using sinewave packet excitation method and compared to the corresponding data from pulse excitation method with a particular emphasis on low frequency behavior below 20 kHz, down to...

Full description

Bibliographic Details
Main Author: Kanji Ono
Format: Article
Language:English
Published: MDPI AG 2018-11-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/18/11/3861
id doaj-c903e7ea3fea41ce982bac4918163e34
record_format Article
spelling doaj-c903e7ea3fea41ce982bac4918163e342020-11-24T22:49:35ZengMDPI AGSensors1424-82202018-11-011811386110.3390/s18113861s18113861Frequency Dependence of Receiving Sensitivity of Ultrasonic Transducers and Acoustic Emission SensorsKanji Ono0Department of Materials Science and Engineering, University of California, Los Angeles (UCLA), Los Angeles, CA 90095, USAReceiving displacement sensitivities (Rx) of ultrasonic transducers and acoustic emission (AE) sensors are evaluated using sinewave packet excitation method and compared to the corresponding data from pulse excitation method with a particular emphasis on low frequency behavior below 20 kHz, down to 10 Hz. Both methods rely on the determination of transmitter displacement characteristics using a laser interferometric method. Results obtained by two calibration methods are in good agreement, with average spectral differences below 1 dB, indicating that the two calibration methods yield identical receiving sensitivities. At low test frequencies, effects of attenuation increase substantially due to increasing sensor impedance and Rx requires correction in order to evaluate the inherent sensitivity of a sensor, or open-circuit sensitivity. This can differ by more than 20 dB from results that used common preamplifiers with ~10 kΩ input impedance, leading to apparent velocity response below 100 kHz for typical AE sensors. Damped broadband sensors and ultrasonic transducers exhibit inherent velocity response (Type 1) below their main resonance frequency. In sensors with under-damped resonance, a steep sensitivity decrease occurs showing frequency dependence of f<sup>2</sup>~f<sup>5</sup> (Type 2), while mass-loaded sensors exhibit flat displacement response (Type 0). Such behaviors originate from sensor characteristics that can best be described by the damped harmonic oscillator model. This model accounts for the three typical behaviors. At low frequencies, typically below 1 kHz, receiving sensitivity exhibits another Type 0 behavior of frequency independent Rx. Seven of 12 sensors showed this flat region, while three more appear to approach the Type 0 region. This appears to originate from the quasi-static piezoelectric response of a sensing element. In using impulse method, a minimum pulse duration is necessary to obtain spectral fidelity at low frequencies and an approximate rule is given. Various factors for sensitivity improvement are also discussed.https://www.mdpi.com/1424-8220/18/11/3861ultrasonic transducersacoustic emission sensorsreceiving sensitivitylow frequency characteristicssinewave excitationimpulse methodopen-circuit sensitivityinput impedancefrequency independent sensitivitydamped harmonic oscillatorminimum pulse duration
collection DOAJ
language English
format Article
sources DOAJ
author Kanji Ono
spellingShingle Kanji Ono
Frequency Dependence of Receiving Sensitivity of Ultrasonic Transducers and Acoustic Emission Sensors
Sensors
ultrasonic transducers
acoustic emission sensors
receiving sensitivity
low frequency characteristics
sinewave excitation
impulse method
open-circuit sensitivity
input impedance
frequency independent sensitivity
damped harmonic oscillator
minimum pulse duration
author_facet Kanji Ono
author_sort Kanji Ono
title Frequency Dependence of Receiving Sensitivity of Ultrasonic Transducers and Acoustic Emission Sensors
title_short Frequency Dependence of Receiving Sensitivity of Ultrasonic Transducers and Acoustic Emission Sensors
title_full Frequency Dependence of Receiving Sensitivity of Ultrasonic Transducers and Acoustic Emission Sensors
title_fullStr Frequency Dependence of Receiving Sensitivity of Ultrasonic Transducers and Acoustic Emission Sensors
title_full_unstemmed Frequency Dependence of Receiving Sensitivity of Ultrasonic Transducers and Acoustic Emission Sensors
title_sort frequency dependence of receiving sensitivity of ultrasonic transducers and acoustic emission sensors
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2018-11-01
description Receiving displacement sensitivities (Rx) of ultrasonic transducers and acoustic emission (AE) sensors are evaluated using sinewave packet excitation method and compared to the corresponding data from pulse excitation method with a particular emphasis on low frequency behavior below 20 kHz, down to 10 Hz. Both methods rely on the determination of transmitter displacement characteristics using a laser interferometric method. Results obtained by two calibration methods are in good agreement, with average spectral differences below 1 dB, indicating that the two calibration methods yield identical receiving sensitivities. At low test frequencies, effects of attenuation increase substantially due to increasing sensor impedance and Rx requires correction in order to evaluate the inherent sensitivity of a sensor, or open-circuit sensitivity. This can differ by more than 20 dB from results that used common preamplifiers with ~10 kΩ input impedance, leading to apparent velocity response below 100 kHz for typical AE sensors. Damped broadband sensors and ultrasonic transducers exhibit inherent velocity response (Type 1) below their main resonance frequency. In sensors with under-damped resonance, a steep sensitivity decrease occurs showing frequency dependence of f<sup>2</sup>~f<sup>5</sup> (Type 2), while mass-loaded sensors exhibit flat displacement response (Type 0). Such behaviors originate from sensor characteristics that can best be described by the damped harmonic oscillator model. This model accounts for the three typical behaviors. At low frequencies, typically below 1 kHz, receiving sensitivity exhibits another Type 0 behavior of frequency independent Rx. Seven of 12 sensors showed this flat region, while three more appear to approach the Type 0 region. This appears to originate from the quasi-static piezoelectric response of a sensing element. In using impulse method, a minimum pulse duration is necessary to obtain spectral fidelity at low frequencies and an approximate rule is given. Various factors for sensitivity improvement are also discussed.
topic ultrasonic transducers
acoustic emission sensors
receiving sensitivity
low frequency characteristics
sinewave excitation
impulse method
open-circuit sensitivity
input impedance
frequency independent sensitivity
damped harmonic oscillator
minimum pulse duration
url https://www.mdpi.com/1424-8220/18/11/3861
work_keys_str_mv AT kanjiono frequencydependenceofreceivingsensitivityofultrasonictransducersandacousticemissionsensors
_version_ 1725675712007897088