Comprehensive Electric Arc Furnace Electric Energy Consumption Modeling: A Pilot Study

The electric arc furnace operation at the Štore Steel company, one of the largest flat spring steel producers in Europe, consists of charging, melting, refining the chemical composition, adjusting the temperature, and tapping. Knowledge of the consumed energy within the individual electric...

Full description

Bibliographic Details
Main Authors: Miha Kovačič, Klemen Stopar, Robert Vertnik, Božidar Šarler
Format: Article
Language:English
Published: MDPI AG 2019-06-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/12/11/2142
id doaj-c850612204144edc87885626d8e32db8
record_format Article
spelling doaj-c850612204144edc87885626d8e32db82020-11-25T01:30:25ZengMDPI AGEnergies1996-10732019-06-011211214210.3390/en12112142en12112142Comprehensive Electric Arc Furnace Electric Energy Consumption Modeling: A Pilot StudyMiha Kovačič0Klemen Stopar1Robert Vertnik2Božidar Šarler3Štore Steel Ltd., Železarska cesta 3, SI-3220 Štore, SloveniaŠtore Steel Ltd., Železarska cesta 3, SI-3220 Štore, SloveniaŠtore Steel Ltd., Železarska cesta 3, SI-3220 Štore, SloveniaFaculty of Mechanical Engineering, University in Ljubljana, Aškerčeva 6, SI-1000 Ljubljana, SloveniaThe electric arc furnace operation at the Štore Steel company, one of the largest flat spring steel producers in Europe, consists of charging, melting, refining the chemical composition, adjusting the temperature, and tapping. Knowledge of the consumed energy within the individual electric arc operation steps is essential. The electric energy consumption during melting and refining was analyzed including the maintenance and technological delays. In modeling the electric energy consumption, 25 parameters were considered during melting (e.g., coke, dolomite, quantity), refining and tapping (e.g., injected oxygen, carbon, and limestone quantity) that were selected from 3248 consecutively produced batches in 2018. Two approaches were employed for the data analysis: linear regression and genetic programming model. The linear regression model was used in the first randomly generated generations of each of the 100 independent developed civilizations. More accurate models were subsequently obtained during the simulated evolution. The average relative deviation of the linear regression and the genetic programming model predictions from the experimental data were 3.60% and 3.31%, respectively. Both models were subsequently validated by using data from 278 batches produced in 2019, where the maintenance and the technological delays were below 20 minutes per batch. It was possible, based on the linear regression and the genetically developed model, to calculate that the average electric energy consumption could be reduced by up to 1.04% and 1.16%, respectively, in the case of maintenance and other technological delays.https://www.mdpi.com/1996-1073/12/11/2142steelmakingelectric arc furnaceconsumptionelectric energymeltingrefiningtappingmodelinglinear regressiongenetic programming
collection DOAJ
language English
format Article
sources DOAJ
author Miha Kovačič
Klemen Stopar
Robert Vertnik
Božidar Šarler
spellingShingle Miha Kovačič
Klemen Stopar
Robert Vertnik
Božidar Šarler
Comprehensive Electric Arc Furnace Electric Energy Consumption Modeling: A Pilot Study
Energies
steelmaking
electric arc furnace
consumption
electric energy
melting
refining
tapping
modeling
linear regression
genetic programming
author_facet Miha Kovačič
Klemen Stopar
Robert Vertnik
Božidar Šarler
author_sort Miha Kovačič
title Comprehensive Electric Arc Furnace Electric Energy Consumption Modeling: A Pilot Study
title_short Comprehensive Electric Arc Furnace Electric Energy Consumption Modeling: A Pilot Study
title_full Comprehensive Electric Arc Furnace Electric Energy Consumption Modeling: A Pilot Study
title_fullStr Comprehensive Electric Arc Furnace Electric Energy Consumption Modeling: A Pilot Study
title_full_unstemmed Comprehensive Electric Arc Furnace Electric Energy Consumption Modeling: A Pilot Study
title_sort comprehensive electric arc furnace electric energy consumption modeling: a pilot study
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2019-06-01
description The electric arc furnace operation at the Štore Steel company, one of the largest flat spring steel producers in Europe, consists of charging, melting, refining the chemical composition, adjusting the temperature, and tapping. Knowledge of the consumed energy within the individual electric arc operation steps is essential. The electric energy consumption during melting and refining was analyzed including the maintenance and technological delays. In modeling the electric energy consumption, 25 parameters were considered during melting (e.g., coke, dolomite, quantity), refining and tapping (e.g., injected oxygen, carbon, and limestone quantity) that were selected from 3248 consecutively produced batches in 2018. Two approaches were employed for the data analysis: linear regression and genetic programming model. The linear regression model was used in the first randomly generated generations of each of the 100 independent developed civilizations. More accurate models were subsequently obtained during the simulated evolution. The average relative deviation of the linear regression and the genetic programming model predictions from the experimental data were 3.60% and 3.31%, respectively. Both models were subsequently validated by using data from 278 batches produced in 2019, where the maintenance and the technological delays were below 20 minutes per batch. It was possible, based on the linear regression and the genetically developed model, to calculate that the average electric energy consumption could be reduced by up to 1.04% and 1.16%, respectively, in the case of maintenance and other technological delays.
topic steelmaking
electric arc furnace
consumption
electric energy
melting
refining
tapping
modeling
linear regression
genetic programming
url https://www.mdpi.com/1996-1073/12/11/2142
work_keys_str_mv AT mihakovacic comprehensiveelectricarcfurnaceelectricenergyconsumptionmodelingapilotstudy
AT klemenstopar comprehensiveelectricarcfurnaceelectricenergyconsumptionmodelingapilotstudy
AT robertvertnik comprehensiveelectricarcfurnaceelectricenergyconsumptionmodelingapilotstudy
AT bozidarsarler comprehensiveelectricarcfurnaceelectricenergyconsumptionmodelingapilotstudy
_version_ 1725091440307994624