Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.

This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator...

Full description

Bibliographic Details
Main Authors: Guerda Massillon-J L, Diego Cueva-Prócel, Porfirio Díaz-Aguirre, Miguel Rodríguez-Ponce, Flor Herrera-Martínez
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2013-01-01
Series:PLoS ONE
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/23671677/pdf/?tool=EBI
id doaj-c8270cdf443f4b14916068ad253faa38
record_format Article
spelling doaj-c8270cdf443f4b14916068ad253faa382021-03-03T23:22:49ZengPublic Library of Science (PLoS)PLoS ONE1932-62032013-01-0185e6341810.1371/journal.pone.0063418Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.Guerda Massillon-J LDiego Cueva-PrócelPorfirio Díaz-AguirreMiguel Rodríguez-PonceFlor Herrera-MartínezThis work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (MD-V2-55), alanine and thermoluminescent (TLD-100) dosimeters and compared with conventional dosimetry systems. Detectors were calibrated in terms of absorbed dose to water in (60)Co gamma-ray and 6 MV x-ray reference (10×10 cm(2)) fields using an ionization chamber calibrated at a standards laboratory. Absorbed dose to water rate computed with MD-V2-55 was higher than that obtained with the others dosimeters, possibly due to a smaller volume averaging effect. Ratio between the dose-rates determined with each dosimeter and those obtained with the film was evaluated for both treatment modalities. For the LGK, the ratio decreased as the dosimeter size increased and remained constant for collimator diameters larger than 8 mm. The same behaviour was observed for the linac and the ratio increased with field size, independent of the dosimeter used. These behaviours could be explained as an averaging volume effect due to dose gradient and lack of electronic equilibrium. Evaluation of the output factors for the LGK collimators indicated that, even when agreement was observed between Monte Carlo simulation and measurements with different dosimeters, this does not warrant that the absorbed dose to water rate in the field was properly known and thus, investigation of the reference dosimetry should be an important issue. These results indicated that alanine dosimeter provides a high degree of accuracy but cannot be used in fields smaller than 20 mm diameter. Gafchromic film can be considered as a suitable methodology for reference dosimetry. TLD dosimeters are not appropriate in fields smaller than 10 mm diameters.https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/23671677/pdf/?tool=EBI
collection DOAJ
language English
format Article
sources DOAJ
author Guerda Massillon-J L
Diego Cueva-Prócel
Porfirio Díaz-Aguirre
Miguel Rodríguez-Ponce
Flor Herrera-Martínez
spellingShingle Guerda Massillon-J L
Diego Cueva-Prócel
Porfirio Díaz-Aguirre
Miguel Rodríguez-Ponce
Flor Herrera-Martínez
Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.
PLoS ONE
author_facet Guerda Massillon-J L
Diego Cueva-Prócel
Porfirio Díaz-Aguirre
Miguel Rodríguez-Ponce
Flor Herrera-Martínez
author_sort Guerda Massillon-J L
title Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.
title_short Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.
title_full Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.
title_fullStr Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.
title_full_unstemmed Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.
title_sort dosimetry for small fields in stereotactic radiosurgery using gafchromic md-v2-55 film, tld-100 and alanine dosimeters.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2013-01-01
description This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (MD-V2-55), alanine and thermoluminescent (TLD-100) dosimeters and compared with conventional dosimetry systems. Detectors were calibrated in terms of absorbed dose to water in (60)Co gamma-ray and 6 MV x-ray reference (10×10 cm(2)) fields using an ionization chamber calibrated at a standards laboratory. Absorbed dose to water rate computed with MD-V2-55 was higher than that obtained with the others dosimeters, possibly due to a smaller volume averaging effect. Ratio between the dose-rates determined with each dosimeter and those obtained with the film was evaluated for both treatment modalities. For the LGK, the ratio decreased as the dosimeter size increased and remained constant for collimator diameters larger than 8 mm. The same behaviour was observed for the linac and the ratio increased with field size, independent of the dosimeter used. These behaviours could be explained as an averaging volume effect due to dose gradient and lack of electronic equilibrium. Evaluation of the output factors for the LGK collimators indicated that, even when agreement was observed between Monte Carlo simulation and measurements with different dosimeters, this does not warrant that the absorbed dose to water rate in the field was properly known and thus, investigation of the reference dosimetry should be an important issue. These results indicated that alanine dosimeter provides a high degree of accuracy but cannot be used in fields smaller than 20 mm diameter. Gafchromic film can be considered as a suitable methodology for reference dosimetry. TLD dosimeters are not appropriate in fields smaller than 10 mm diameters.
url https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/23671677/pdf/?tool=EBI
work_keys_str_mv AT guerdamassillonjl dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters
AT diegocuevaprocel dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters
AT porfiriodiazaguirre dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters
AT miguelrodriguezponce dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters
AT florherreramartinez dosimetryforsmallfieldsinstereotacticradiosurgeryusinggafchromicmdv255filmtld100andalaninedosimeters
_version_ 1714811695938928640