Influence of Parameter Selection in Fixed Sample Entropy of Surface Diaphragm Electromyography for Estimating Respiratory Activity
Fixed sample entropy (fSampEn) is a robust technique that allows the evaluation of inspiratory effort in diaphragm electromyography (EMGdi) signals, and has potential utility in sleep studies. To appropriately estimate respiratory effort, fSampEn requires the adjustment of several parameters. The ai...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2017-09-01
|
Series: | Entropy |
Subjects: | |
Online Access: | https://www.mdpi.com/1099-4300/19/9/460 |
id |
doaj-c81cfe5a3d47499f8ec44b8ba56e1226 |
---|---|
record_format |
Article |
spelling |
doaj-c81cfe5a3d47499f8ec44b8ba56e12262020-11-24T20:47:59ZengMDPI AGEntropy1099-43002017-09-0119946010.3390/e19090460e19090460Influence of Parameter Selection in Fixed Sample Entropy of Surface Diaphragm Electromyography for Estimating Respiratory ActivityLuis Estrada0Abel Torres1Leonardo Sarlabous2Raimon Jané3Biomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, SpainBiomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, SpainBiomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, SpainBiomedical Signal Processing and Interpretation, Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, SpainFixed sample entropy (fSampEn) is a robust technique that allows the evaluation of inspiratory effort in diaphragm electromyography (EMGdi) signals, and has potential utility in sleep studies. To appropriately estimate respiratory effort, fSampEn requires the adjustment of several parameters. The aims of the present study were to evaluate the influence of the embedding dimension m, the tolerance value r, the size of the moving window, and the sampling frequency, and to establish recommendations for estimating the respiratory activity when using the fSampEn on surface EMGdi recorded for different inspiratory efforts. Values of m equal to 1 and r ranging from 0.1 to 0.64, and m equal to 2 and r ranging from 0.13 to 0.45, were found to be suitable for evaluating respiratory activity. fSampEn was less affected by window size than classical amplitude parameters. Finally, variations in sampling frequency could influence fSampEn results. In conclusion, the findings suggest the potential utility of fSampEn for estimating muscle respiratory effort in further sleep studies.https://www.mdpi.com/1099-4300/19/9/460surface diaphragm electromyographyfixed sample entropy (fSampEn)respiratory activityrespiratory effortnon-invasive respiratory monitoring |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Luis Estrada Abel Torres Leonardo Sarlabous Raimon Jané |
spellingShingle |
Luis Estrada Abel Torres Leonardo Sarlabous Raimon Jané Influence of Parameter Selection in Fixed Sample Entropy of Surface Diaphragm Electromyography for Estimating Respiratory Activity Entropy surface diaphragm electromyography fixed sample entropy (fSampEn) respiratory activity respiratory effort non-invasive respiratory monitoring |
author_facet |
Luis Estrada Abel Torres Leonardo Sarlabous Raimon Jané |
author_sort |
Luis Estrada |
title |
Influence of Parameter Selection in Fixed Sample Entropy of Surface Diaphragm Electromyography for Estimating Respiratory Activity |
title_short |
Influence of Parameter Selection in Fixed Sample Entropy of Surface Diaphragm Electromyography for Estimating Respiratory Activity |
title_full |
Influence of Parameter Selection in Fixed Sample Entropy of Surface Diaphragm Electromyography for Estimating Respiratory Activity |
title_fullStr |
Influence of Parameter Selection in Fixed Sample Entropy of Surface Diaphragm Electromyography for Estimating Respiratory Activity |
title_full_unstemmed |
Influence of Parameter Selection in Fixed Sample Entropy of Surface Diaphragm Electromyography for Estimating Respiratory Activity |
title_sort |
influence of parameter selection in fixed sample entropy of surface diaphragm electromyography for estimating respiratory activity |
publisher |
MDPI AG |
series |
Entropy |
issn |
1099-4300 |
publishDate |
2017-09-01 |
description |
Fixed sample entropy (fSampEn) is a robust technique that allows the evaluation of inspiratory effort in diaphragm electromyography (EMGdi) signals, and has potential utility in sleep studies. To appropriately estimate respiratory effort, fSampEn requires the adjustment of several parameters. The aims of the present study were to evaluate the influence of the embedding dimension m, the tolerance value r, the size of the moving window, and the sampling frequency, and to establish recommendations for estimating the respiratory activity when using the fSampEn on surface EMGdi recorded for different inspiratory efforts. Values of m equal to 1 and r ranging from 0.1 to 0.64, and m equal to 2 and r ranging from 0.13 to 0.45, were found to be suitable for evaluating respiratory activity. fSampEn was less affected by window size than classical amplitude parameters. Finally, variations in sampling frequency could influence fSampEn results. In conclusion, the findings suggest the potential utility of fSampEn for estimating muscle respiratory effort in further sleep studies. |
topic |
surface diaphragm electromyography fixed sample entropy (fSampEn) respiratory activity respiratory effort non-invasive respiratory monitoring |
url |
https://www.mdpi.com/1099-4300/19/9/460 |
work_keys_str_mv |
AT luisestrada influenceofparameterselectioninfixedsampleentropyofsurfacediaphragmelectromyographyforestimatingrespiratoryactivity AT abeltorres influenceofparameterselectioninfixedsampleentropyofsurfacediaphragmelectromyographyforestimatingrespiratoryactivity AT leonardosarlabous influenceofparameterselectioninfixedsampleentropyofsurfacediaphragmelectromyographyforestimatingrespiratoryactivity AT raimonjane influenceofparameterselectioninfixedsampleentropyofsurfacediaphragmelectromyographyforestimatingrespiratoryactivity |
_version_ |
1716809321854009344 |