INDIRECT METHODS OF MEASURING FLОW RATE AND PRESSURE DROP OF ROTARY BLOOD PUMPS

The article describes complex software to calculate the main parameters of the axial pump (pressure drop and flow rate) on the basis of an analysis of its technical characteristics (current consumption and pump speed). It is shown that the calculated value of pressure drop and flow rate throughout t...

Full description

Bibliographic Details
Main Authors: G. P. Itkin, I. A. Filatov, K. N. Dozorov, A. V. Adaskin
Format: Article
Language:Russian
Published: Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov 2015-04-01
Series:Vestnik Transplantologii i Iskusstvennyh Organov
Subjects:
Online Access:https://journal.transpl.ru/vtio/article/view/501
id doaj-c8109734f25740069c63f6697aa9de55
record_format Article
spelling doaj-c8109734f25740069c63f6697aa9de552021-07-29T09:08:30ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov Vestnik Transplantologii i Iskusstvennyh Organov1995-11912015-04-011719710210.15825/1995-1191-2015-1-97-102436INDIRECT METHODS OF MEASURING FLОW RATE AND PRESSURE DROP OF ROTARY BLOOD PUMPSG. P. Itkin0I. A. Filatov1K. N. Dozorov2A. V. Adaskin3V.I. Schumakov Federal Research Center of Transplantology and Artificial Organs, Moscow, Russian FederationV.I. Schumakov Federal Research Center of Transplantology and Artificial Organs, Moscow, Russian FederationV.I. Schumakov Federal Research Center of Transplantology and Artificial Organs, Moscow, Russian FederationV.I. Schumakov Federal Research Center of Transplantology and Artificial Organs, Moscow, Russian FederationThe article describes complex software to calculate the main parameters of the axial pump (pressure drop and flow rate) on the basis of an analysis of its technical characteristics (current consumption and pump speed). It is shown that the calculated value of pressure drop and flow rate throughout the range of operating loads and pump speeds is different from the measured one by no more than 10%. It is shown that this software package may be included in the control system of axial pump.https://journal.transpl.ru/vtio/article/view/501rotary pumppump speedflow ratepressure dropcontrol systemnoninvasive monitoringcurrent consumption
collection DOAJ
language Russian
format Article
sources DOAJ
author G. P. Itkin
I. A. Filatov
K. N. Dozorov
A. V. Adaskin
spellingShingle G. P. Itkin
I. A. Filatov
K. N. Dozorov
A. V. Adaskin
INDIRECT METHODS OF MEASURING FLОW RATE AND PRESSURE DROP OF ROTARY BLOOD PUMPS
Vestnik Transplantologii i Iskusstvennyh Organov
rotary pump
pump speed
flow rate
pressure drop
control system
noninvasive monitoring
current consumption
author_facet G. P. Itkin
I. A. Filatov
K. N. Dozorov
A. V. Adaskin
author_sort G. P. Itkin
title INDIRECT METHODS OF MEASURING FLОW RATE AND PRESSURE DROP OF ROTARY BLOOD PUMPS
title_short INDIRECT METHODS OF MEASURING FLОW RATE AND PRESSURE DROP OF ROTARY BLOOD PUMPS
title_full INDIRECT METHODS OF MEASURING FLОW RATE AND PRESSURE DROP OF ROTARY BLOOD PUMPS
title_fullStr INDIRECT METHODS OF MEASURING FLОW RATE AND PRESSURE DROP OF ROTARY BLOOD PUMPS
title_full_unstemmed INDIRECT METHODS OF MEASURING FLОW RATE AND PRESSURE DROP OF ROTARY BLOOD PUMPS
title_sort indirect methods of measuring flоw rate and pressure drop of rotary blood pumps
publisher Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
series Vestnik Transplantologii i Iskusstvennyh Organov
issn 1995-1191
publishDate 2015-04-01
description The article describes complex software to calculate the main parameters of the axial pump (pressure drop and flow rate) on the basis of an analysis of its technical characteristics (current consumption and pump speed). It is shown that the calculated value of pressure drop and flow rate throughout the range of operating loads and pump speeds is different from the measured one by no more than 10%. It is shown that this software package may be included in the control system of axial pump.
topic rotary pump
pump speed
flow rate
pressure drop
control system
noninvasive monitoring
current consumption
url https://journal.transpl.ru/vtio/article/view/501
work_keys_str_mv AT gpitkin indirectmethodsofmeasuringflowrateandpressuredropofrotarybloodpumps
AT iafilatov indirectmethodsofmeasuringflowrateandpressuredropofrotarybloodpumps
AT kndozorov indirectmethodsofmeasuringflowrateandpressuredropofrotarybloodpumps
AT avadaskin indirectmethodsofmeasuringflowrateandpressuredropofrotarybloodpumps
_version_ 1721249222137741312