Control Characteristic Analysis and Coordinated Strategy Design for Hybrid HVDC With Multi-Infeed MMC Inverters

The hybrid HVDC with cascaded multi-infeed MMC inverters is proposed in recent years and it will be put into reality in near future. But the control characteristic of this hybrid HVDC have not been discussed in details. This paper investigates the control strategy characteristic of the hybrid HVDC u...

Full description

Bibliographic Details
Main Authors: Jingbo Zhao, Yan Tao
Format: Article
Language:English
Published: Frontiers Media S.A. 2021-09-01
Series:Frontiers in Energy Research
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fenrg.2021.737294/full
id doaj-c7bf9052add94b59a5ad3441b58bb4cd
record_format Article
spelling doaj-c7bf9052add94b59a5ad3441b58bb4cd2021-09-23T05:03:08ZengFrontiers Media S.A.Frontiers in Energy Research2296-598X2021-09-01910.3389/fenrg.2021.737294737294Control Characteristic Analysis and Coordinated Strategy Design for Hybrid HVDC With Multi-Infeed MMC InvertersJingbo ZhaoYan TaoThe hybrid HVDC with cascaded multi-infeed MMC inverters is proposed in recent years and it will be put into reality in near future. But the control characteristic of this hybrid HVDC have not been discussed in details. This paper investigates the control strategy characteristic of the hybrid HVDC using cascaded multi-infeed MMC inverters. By combining the UI curves (the DC voltage and DC current curves) of LCC rectifiers, LCC inverter and MMC inverters, the complete UI curves of the hybrid HVDC are obtained in different control modes. Through the complete UI curve, the characteristic of the control strategy is investigated in different operation situations. It is found that the MMC inverter in DC voltage control could shift to the rectifying mode if the fault occurs or active power orders are intensively changed. To solve such problem, the coordinated control strategy based on the dynamic limiter, diodes and LCC-MMC active orders is proposed in this paper, which can not only prevent the MMC inverter from becoming a rectifier at DC side but also can improve the AC side voltage stability. Nevertheless, the proposed strategy can further endow the MMC with fault ride through abilities. The simulations in PSCAD software verify the correctness and effectiveness of the proposed control strategy.https://www.frontiersin.org/articles/10.3389/fenrg.2021.737294/fullhybrid HVDCcontrol characteristiccoordinated control strategycascaded MMCmulti-infeed inverters
collection DOAJ
language English
format Article
sources DOAJ
author Jingbo Zhao
Yan Tao
spellingShingle Jingbo Zhao
Yan Tao
Control Characteristic Analysis and Coordinated Strategy Design for Hybrid HVDC With Multi-Infeed MMC Inverters
Frontiers in Energy Research
hybrid HVDC
control characteristic
coordinated control strategy
cascaded MMC
multi-infeed inverters
author_facet Jingbo Zhao
Yan Tao
author_sort Jingbo Zhao
title Control Characteristic Analysis and Coordinated Strategy Design for Hybrid HVDC With Multi-Infeed MMC Inverters
title_short Control Characteristic Analysis and Coordinated Strategy Design for Hybrid HVDC With Multi-Infeed MMC Inverters
title_full Control Characteristic Analysis and Coordinated Strategy Design for Hybrid HVDC With Multi-Infeed MMC Inverters
title_fullStr Control Characteristic Analysis and Coordinated Strategy Design for Hybrid HVDC With Multi-Infeed MMC Inverters
title_full_unstemmed Control Characteristic Analysis and Coordinated Strategy Design for Hybrid HVDC With Multi-Infeed MMC Inverters
title_sort control characteristic analysis and coordinated strategy design for hybrid hvdc with multi-infeed mmc inverters
publisher Frontiers Media S.A.
series Frontiers in Energy Research
issn 2296-598X
publishDate 2021-09-01
description The hybrid HVDC with cascaded multi-infeed MMC inverters is proposed in recent years and it will be put into reality in near future. But the control characteristic of this hybrid HVDC have not been discussed in details. This paper investigates the control strategy characteristic of the hybrid HVDC using cascaded multi-infeed MMC inverters. By combining the UI curves (the DC voltage and DC current curves) of LCC rectifiers, LCC inverter and MMC inverters, the complete UI curves of the hybrid HVDC are obtained in different control modes. Through the complete UI curve, the characteristic of the control strategy is investigated in different operation situations. It is found that the MMC inverter in DC voltage control could shift to the rectifying mode if the fault occurs or active power orders are intensively changed. To solve such problem, the coordinated control strategy based on the dynamic limiter, diodes and LCC-MMC active orders is proposed in this paper, which can not only prevent the MMC inverter from becoming a rectifier at DC side but also can improve the AC side voltage stability. Nevertheless, the proposed strategy can further endow the MMC with fault ride through abilities. The simulations in PSCAD software verify the correctness and effectiveness of the proposed control strategy.
topic hybrid HVDC
control characteristic
coordinated control strategy
cascaded MMC
multi-infeed inverters
url https://www.frontiersin.org/articles/10.3389/fenrg.2021.737294/full
work_keys_str_mv AT jingbozhao controlcharacteristicanalysisandcoordinatedstrategydesignforhybridhvdcwithmultiinfeedmmcinverters
AT yantao controlcharacteristicanalysisandcoordinatedstrategydesignforhybridhvdcwithmultiinfeedmmcinverters
_version_ 1717370648896995328