Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro study

Objectives: The objective of this in vitro study was to compare the microtensile dentin bond strength (μTBS) of five seventh-generation dentin bonding agents (DBA) with fifth-generation DBA before and after thermocycling. Materials and Methods: Ten extracted teeth were assigned to fifth generation c...

Full description

Bibliographic Details
Main Authors: Bruhvi Poptani, K S Gohil, Jaishree Ganjiwale, Manisha Shukla
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2012-01-01
Series:Contemporary Clinical Dentistry
Subjects:
Online Access:http://www.contempclindent.org/article.asp?issn=0976-237X;year=2012;volume=3;issue=6;spage=167;epage=171;aulast=Poptani
id doaj-c6bc52eec94d411286dfa83bfacff853
record_format Article
spelling doaj-c6bc52eec94d411286dfa83bfacff8532020-11-24T21:44:33ZengWolters Kluwer Medknow PublicationsContemporary Clinical Dentistry0976-237X0976-23612012-01-013616717110.4103/0976-237X.101079Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro studyBruhvi PoptaniK S GohilJaishree GanjiwaleManisha ShuklaObjectives: The objective of this in vitro study was to compare the microtensile dentin bond strength (μTBS) of five seventh-generation dentin bonding agents (DBA) with fifth-generation DBA before and after thermocycling. Materials and Methods: Ten extracted teeth were assigned to fifth generation control group (optibond solo) and each of the five experimental groups namely, Group I (G-Bond) ,Group II (S 3 Clearfil), Group III (One Coat 7.0), Group IV (Xeno V), and Group V (Optibond all in one). The crown portions of the teeth were horizontally sectioned below the central groove to expose the dentin. The adhesive resins from all groups were bonded to the teeth with their respective composites. Specimens of sizes 1 × 1 × 6 mm 3 were obtained. Fifty specimens that bonded to dentin from each group were selected. Twenty-five of the specimens were tested for debonding without thermocycling and the remaining were subjected to thermocycling followed by μTBS testing. The data were analyzed with one-way ANOVA and Dunnett′s-test for comparison with the reference group(Vth Generation). Results: There was no significant difference (P > 0.05) between the fifth- and seventh-generation adhesives before and after thermocycling. The results of our study showed significantly higher value (P < 0.05) of μTBS of seventh-generation Group II (Clearfil S 3 ) compared to the fifth-generation before and after thermocycling. Conclusion: The study demonstrated that the Clearfil S 3 bond had the highest μTBS values. In addition, of the five tested seventh-generation adhesive resins were comparable to the fifth-generation DBA.http://www.contempclindent.org/article.asp?issn=0976-237X;year=2012;volume=3;issue=6;spage=167;epage=171;aulast=PoptaniClearfil S3G-bondmicrotensile bond strengthoptibond soloone coat 7.0optibond all in onethermocyclingXeno V
collection DOAJ
language English
format Article
sources DOAJ
author Bruhvi Poptani
K S Gohil
Jaishree Ganjiwale
Manisha Shukla
spellingShingle Bruhvi Poptani
K S Gohil
Jaishree Ganjiwale
Manisha Shukla
Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro study
Contemporary Clinical Dentistry
Clearfil S3
G-bond
microtensile bond strength
optibond solo
one coat 7.0
optibond all in one
thermocycling
Xeno V
author_facet Bruhvi Poptani
K S Gohil
Jaishree Ganjiwale
Manisha Shukla
author_sort Bruhvi Poptani
title Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro study
title_short Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro study
title_full Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro study
title_fullStr Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro study
title_full_unstemmed Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro study
title_sort microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: an in vitro study
publisher Wolters Kluwer Medknow Publications
series Contemporary Clinical Dentistry
issn 0976-237X
0976-2361
publishDate 2012-01-01
description Objectives: The objective of this in vitro study was to compare the microtensile dentin bond strength (μTBS) of five seventh-generation dentin bonding agents (DBA) with fifth-generation DBA before and after thermocycling. Materials and Methods: Ten extracted teeth were assigned to fifth generation control group (optibond solo) and each of the five experimental groups namely, Group I (G-Bond) ,Group II (S 3 Clearfil), Group III (One Coat 7.0), Group IV (Xeno V), and Group V (Optibond all in one). The crown portions of the teeth were horizontally sectioned below the central groove to expose the dentin. The adhesive resins from all groups were bonded to the teeth with their respective composites. Specimens of sizes 1 × 1 × 6 mm 3 were obtained. Fifty specimens that bonded to dentin from each group were selected. Twenty-five of the specimens were tested for debonding without thermocycling and the remaining were subjected to thermocycling followed by μTBS testing. The data were analyzed with one-way ANOVA and Dunnett′s-test for comparison with the reference group(Vth Generation). Results: There was no significant difference (P > 0.05) between the fifth- and seventh-generation adhesives before and after thermocycling. The results of our study showed significantly higher value (P < 0.05) of μTBS of seventh-generation Group II (Clearfil S 3 ) compared to the fifth-generation before and after thermocycling. Conclusion: The study demonstrated that the Clearfil S 3 bond had the highest μTBS values. In addition, of the five tested seventh-generation adhesive resins were comparable to the fifth-generation DBA.
topic Clearfil S3
G-bond
microtensile bond strength
optibond solo
one coat 7.0
optibond all in one
thermocycling
Xeno V
url http://www.contempclindent.org/article.asp?issn=0976-237X;year=2012;volume=3;issue=6;spage=167;epage=171;aulast=Poptani
work_keys_str_mv AT bruhvipoptani microtensiledentinbondstrengthoffifthwithfiveseventhgenerationdentinbondingagentsafterthermocyclinganinvitrostudy
AT ksgohil microtensiledentinbondstrengthoffifthwithfiveseventhgenerationdentinbondingagentsafterthermocyclinganinvitrostudy
AT jaishreeganjiwale microtensiledentinbondstrengthoffifthwithfiveseventhgenerationdentinbondingagentsafterthermocyclinganinvitrostudy
AT manishashukla microtensiledentinbondstrengthoffifthwithfiveseventhgenerationdentinbondingagentsafterthermocyclinganinvitrostudy
_version_ 1725909518031781888