Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population
Purpose: Standard achromatic perimetry tests the differential light sensitivity whereas the frequency doubling technology tests the contrast sensitivity. The aim of this study was to compare and correlate the visual field indices with three different types of perimeters namely frequency doubling...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
JCDR Research and Publications Private Limited
2015-07-01
|
Series: | Journal of Clinical and Diagnostic Research |
Subjects: | |
Online Access: | https://jcdr.net/articles/PDF/6204/13001_CE(Ra1)_F(GH)_PF1(PAK)_PFA(AK)_PF2(PAG).pdf |
id |
doaj-c649834ea47649e8b2830f084048931b |
---|---|
record_format |
Article |
spelling |
doaj-c649834ea47649e8b2830f084048931b2020-11-25T03:39:19ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2015-07-0197NC01NC0310.7860/JCDR/2015/13001.6204Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian PopulationAR RAJALAKSHMI0ELANGOVAN SUMA1D RANJIT PRABHU2Associate Professor, Department of Ophthalmology, Mahatma Gandhi medical college & research institute, Pondicherry, India.Associate Professor, Department of ophthalmology, ESIC medical college and PGIMSR, K.K.Nagar, Chennai, India.Consultant, Nellai Eye Care Institute, 106 B2& B3 South Mount Road, Tirunelveli, India.Purpose: Standard achromatic perimetry tests the differential light sensitivity whereas the frequency doubling technology tests the contrast sensitivity. The aim of this study was to compare and correlate the visual field indices with three different types of perimeters namely frequency doubling perimetry (FDP), Humphrey field analyser (HFA) and Octopus Interzeag 1-2-3 (OI) for detecting glaucomatous field defects. Design: Prospective cross-sectional observational study. Materials and Methods: Hundred eyes of 50 glaucoma patients were studied. All the patients underwent visual field examinations by Octopus Interzeag 1-2-3, Humphrey field Analyser II and Frequency Doubling perimetry (FDP). The correlations of the global indices were compared. The time taken to perform the test with the three perimeters was analysed. Results: The visual field plotting by the perimeters were comparable and significant positive correlation was observed. The time taken to perform visual field test by Octopus Interzeag 1-2-3 was shorter than the other two methods. Conclusion: The visual field plotting by Octopus Interzeag 1-2-3, Humphrey field analyser and frequency doubling technology perimetry were comparable and Octopus field plotting takes lesser time than the rest two methods.https://jcdr.net/articles/PDF/6204/13001_CE(Ra1)_F(GH)_PF1(PAK)_PFA(AK)_PF2(PAG).pdffield defectsfrequency doubling technologystandard achromatic perimetrytime durationvisual field indices |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
AR RAJALAKSHMI ELANGOVAN SUMA D RANJIT PRABHU |
spellingShingle |
AR RAJALAKSHMI ELANGOVAN SUMA D RANJIT PRABHU Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population Journal of Clinical and Diagnostic Research field defects frequency doubling technology standard achromatic perimetry time duration visual field indices |
author_facet |
AR RAJALAKSHMI ELANGOVAN SUMA D RANJIT PRABHU |
author_sort |
AR RAJALAKSHMI |
title |
Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population |
title_short |
Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population |
title_full |
Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population |
title_fullStr |
Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population |
title_full_unstemmed |
Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population |
title_sort |
comparative analysis of visual field plotting by octopus interzeag 1-2-3, humphrey field analyser ii and frequency doubling perimetry in glaucoma patients in south indian population |
publisher |
JCDR Research and Publications Private Limited |
series |
Journal of Clinical and Diagnostic Research |
issn |
2249-782X 0973-709X |
publishDate |
2015-07-01 |
description |
Purpose: Standard achromatic perimetry tests the differential
light sensitivity whereas the frequency doubling technology tests
the contrast sensitivity. The aim of this study was to compare
and correlate the visual field indices with three different types
of perimeters namely frequency doubling perimetry (FDP),
Humphrey field analyser (HFA) and Octopus Interzeag 1-2-3 (OI)
for detecting glaucomatous field defects.
Design: Prospective cross-sectional observational study.
Materials and Methods: Hundred eyes of 50 glaucoma patients
were studied. All the patients underwent visual field examinations
by Octopus Interzeag 1-2-3, Humphrey field Analyser II and
Frequency Doubling perimetry (FDP). The correlations of the
global indices were compared. The time taken to perform the
test with the three perimeters was analysed.
Results: The visual field plotting by the perimeters were
comparable and significant positive correlation was observed.
The time taken to perform visual field test by Octopus Interzeag
1-2-3 was shorter than the other two methods.
Conclusion: The visual field plotting by Octopus Interzeag 1-2-3,
Humphrey field analyser and frequency doubling technology
perimetry were comparable and Octopus field plotting takes
lesser time than the rest two methods. |
topic |
field defects frequency doubling technology standard achromatic perimetry time duration visual field indices |
url |
https://jcdr.net/articles/PDF/6204/13001_CE(Ra1)_F(GH)_PF1(PAK)_PFA(AK)_PF2(PAG).pdf |
work_keys_str_mv |
AT arrajalakshmi comparativeanalysisofvisualfieldplottingbyoctopusinterzeag123humphreyfieldanalyseriiandfrequencydoublingperimetryinglaucomapatientsinsouthindianpopulation AT elangovansuma comparativeanalysisofvisualfieldplottingbyoctopusinterzeag123humphreyfieldanalyseriiandfrequencydoublingperimetryinglaucomapatientsinsouthindianpopulation AT dranjitprabhu comparativeanalysisofvisualfieldplottingbyoctopusinterzeag123humphreyfieldanalyseriiandfrequencydoublingperimetryinglaucomapatientsinsouthindianpopulation |
_version_ |
1724539540043988992 |