Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population

Purpose: Standard achromatic perimetry tests the differential light sensitivity whereas the frequency doubling technology tests the contrast sensitivity. The aim of this study was to compare and correlate the visual field indices with three different types of perimeters namely frequency doubling...

Full description

Bibliographic Details
Main Authors: AR RAJALAKSHMI, ELANGOVAN SUMA, D RANJIT PRABHU
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2015-07-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://jcdr.net/articles/PDF/6204/13001_CE(Ra1)_F(GH)_PF1(PAK)_PFA(AK)_PF2(PAG).pdf
id doaj-c649834ea47649e8b2830f084048931b
record_format Article
spelling doaj-c649834ea47649e8b2830f084048931b2020-11-25T03:39:19ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2015-07-0197NC01NC0310.7860/JCDR/2015/13001.6204Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian PopulationAR RAJALAKSHMI0ELANGOVAN SUMA1D RANJIT PRABHU2Associate Professor, Department of Ophthalmology, Mahatma Gandhi medical college & research institute, Pondicherry, India.Associate Professor, Department of ophthalmology, ESIC medical college and PGIMSR, K.K.Nagar, Chennai, India.Consultant, Nellai Eye Care Institute, 106 B2& B3 South Mount Road, Tirunelveli, India.Purpose: Standard achromatic perimetry tests the differential light sensitivity whereas the frequency doubling technology tests the contrast sensitivity. The aim of this study was to compare and correlate the visual field indices with three different types of perimeters namely frequency doubling perimetry (FDP), Humphrey field analyser (HFA) and Octopus Interzeag 1-2-3 (OI) for detecting glaucomatous field defects. Design: Prospective cross-sectional observational study. Materials and Methods: Hundred eyes of 50 glaucoma patients were studied. All the patients underwent visual field examinations by Octopus Interzeag 1-2-3, Humphrey field Analyser II and Frequency Doubling perimetry (FDP). The correlations of the global indices were compared. The time taken to perform the test with the three perimeters was analysed. Results: The visual field plotting by the perimeters were comparable and significant positive correlation was observed. The time taken to perform visual field test by Octopus Interzeag 1-2-3 was shorter than the other two methods. Conclusion: The visual field plotting by Octopus Interzeag 1-2-3, Humphrey field analyser and frequency doubling technology perimetry were comparable and Octopus field plotting takes lesser time than the rest two methods.https://jcdr.net/articles/PDF/6204/13001_CE(Ra1)_F(GH)_PF1(PAK)_PFA(AK)_PF2(PAG).pdffield defectsfrequency doubling technologystandard achromatic perimetrytime durationvisual field indices
collection DOAJ
language English
format Article
sources DOAJ
author AR RAJALAKSHMI
ELANGOVAN SUMA
D RANJIT PRABHU
spellingShingle AR RAJALAKSHMI
ELANGOVAN SUMA
D RANJIT PRABHU
Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population
Journal of Clinical and Diagnostic Research
field defects
frequency doubling technology
standard achromatic perimetry
time duration
visual field indices
author_facet AR RAJALAKSHMI
ELANGOVAN SUMA
D RANJIT PRABHU
author_sort AR RAJALAKSHMI
title Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population
title_short Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population
title_full Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population
title_fullStr Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population
title_full_unstemmed Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population
title_sort comparative analysis of visual field plotting by octopus interzeag 1-2-3, humphrey field analyser ii and frequency doubling perimetry in glaucoma patients in south indian population
publisher JCDR Research and Publications Private Limited
series Journal of Clinical and Diagnostic Research
issn 2249-782X
0973-709X
publishDate 2015-07-01
description Purpose: Standard achromatic perimetry tests the differential light sensitivity whereas the frequency doubling technology tests the contrast sensitivity. The aim of this study was to compare and correlate the visual field indices with three different types of perimeters namely frequency doubling perimetry (FDP), Humphrey field analyser (HFA) and Octopus Interzeag 1-2-3 (OI) for detecting glaucomatous field defects. Design: Prospective cross-sectional observational study. Materials and Methods: Hundred eyes of 50 glaucoma patients were studied. All the patients underwent visual field examinations by Octopus Interzeag 1-2-3, Humphrey field Analyser II and Frequency Doubling perimetry (FDP). The correlations of the global indices were compared. The time taken to perform the test with the three perimeters was analysed. Results: The visual field plotting by the perimeters were comparable and significant positive correlation was observed. The time taken to perform visual field test by Octopus Interzeag 1-2-3 was shorter than the other two methods. Conclusion: The visual field plotting by Octopus Interzeag 1-2-3, Humphrey field analyser and frequency doubling technology perimetry were comparable and Octopus field plotting takes lesser time than the rest two methods.
topic field defects
frequency doubling technology
standard achromatic perimetry
time duration
visual field indices
url https://jcdr.net/articles/PDF/6204/13001_CE(Ra1)_F(GH)_PF1(PAK)_PFA(AK)_PF2(PAG).pdf
work_keys_str_mv AT arrajalakshmi comparativeanalysisofvisualfieldplottingbyoctopusinterzeag123humphreyfieldanalyseriiandfrequencydoublingperimetryinglaucomapatientsinsouthindianpopulation
AT elangovansuma comparativeanalysisofvisualfieldplottingbyoctopusinterzeag123humphreyfieldanalyseriiandfrequencydoublingperimetryinglaucomapatientsinsouthindianpopulation
AT dranjitprabhu comparativeanalysisofvisualfieldplottingbyoctopusinterzeag123humphreyfieldanalyseriiandfrequencydoublingperimetryinglaucomapatientsinsouthindianpopulation
_version_ 1724539540043988992