Wind suction resistance of innovative roofing kits based on ceramic tiles. A preliminar technical assessment = Resistencia a la succión del viento de sistemas innovadores de tejados con tejas cerámicas. Evaluación técnica preliminar

DuPitched roof based on tiles avoid wind uplift by providing and adequate mechanically fixing pattern to support. This goal should be achieved according to specifications and zoning maps from the installation standard for ceramic tiles roofs UNE 136020 recognized by Basic Document CTE DB-HS-1 for ce...

Full description

Bibliographic Details
Main Author: Eduardo Lahoz Ruiz
Format: Article
Language:Spanish
Published: Universidad Politécnica de Madrid 2019-12-01
Series:Building & Management
Subjects:
Online Access:http://polired.upm.es/index.php/building_management/article/view/4036
id doaj-c61a2f1617d44ec18aa4f87f65905d02
record_format Article
spelling doaj-c61a2f1617d44ec18aa4f87f65905d022020-11-25T01:30:01ZspaUniversidad Politécnica de Madrid Building & Management2530-81572019-12-0133475510.20868/bma.2019.3.40363894Wind suction resistance of innovative roofing kits based on ceramic tiles. A preliminar technical assessment = Resistencia a la succión del viento de sistemas innovadores de tejados con tejas cerámicas. Evaluación técnica preliminarEduardo Lahoz Ruiz0Universidad Politécnica de MadridDuPitched roof based on tiles avoid wind uplift by providing and adequate mechanically fixing pattern to support. This goal should be achieved according to specifications and zoning maps from the installation standard for ceramic tiles roofs UNE 136020 recognized by Basic Document CTE DB-HS-1 for ceramic tiles roofing. Nevertheless, this Document and DB-SE-AE refers to an updated and different map for the calculation of wind actions for façades. In this incoherent regulation context, new full-dry installed innovative roofing kits require of a preliminary and faster procedure for technical assessment regarding its fitness for use. This scope requires focusing firstly on the most critical requirement, Safety, considering only its wind uplift behaviour. For this purpose, once objectives were defined, the State of the Art analyzed, an experimental study was carried out regarding pull out test of fixing tiles screws to profiles and wind uplift of kit according to EN 14437, completed with worksite inspection. The results lead to the principal conclusion: It was feasible to carry out a preliminary and partial technical evaluation of fitness for use of roofing kits based on the contribution to compliance with the basic safety requirement by determining the resistance to wind suction considering the application of the DB-SE-AE of CTE. Resumen Las cubiertas inclinadas a base de tejas evitan su levantamiento por el viento mediante un adecuado patrón de fijación mecánica a su elemento soporte. Este objetivo se alcanzaría cumpliendo las especificaciones del texto y mapas de datos de la Norma UNE 136020, para montaje de tejados con tejas cerámicas, reconocida por el Documento Básico del CTE DB-HS-1. Sin embargo, este mismo documento considera otros criterios de cálculo y mapas de datos diferentes para fachadas. En este incoherente contexto normativo, nuevos sistemas innovadores de tejados a base de tejas instalados totalmente en seco, requieren de un procedimiento preliminar y rápido para la evaluación técnica de su aptitud de empleo. Este objetivo supone dirigirse en primer lugar hacia la evaluación de la exigencia más crítica, la Seguridad, considerando únicamente el comportamiento frente a la succión del viento del sistema. Para este fin, una vez definidos los objetivos y analizado el estado del conocimiento, se realizó un estudio experimental relativao a la resistencia al arrancamiento del tornillo que fija la teja al rastrel así como del comportamiento del sistema frente a la succión del viento según los procedimientos de la Norma UNE EN 14437, completado con una visita previa de obra. Se concluyó que sí era viable realizar una evaluación técnica preliminar y favorable de la idoneidad de empleo de un sistema innovador de cubiertas, centrándose en la contribución a la Seguridad, considerando la aplicación del CTE-DB-SE-AE.http://polired.upm.es/index.php/building_management/article/view/4036innovative roofing kittechnical assessmentceramic tileswind upliftsistema innovador de cubiertaevaluación técnicatejas cerámicassucción de viento
collection DOAJ
language Spanish
format Article
sources DOAJ
author Eduardo Lahoz Ruiz
spellingShingle Eduardo Lahoz Ruiz
Wind suction resistance of innovative roofing kits based on ceramic tiles. A preliminar technical assessment = Resistencia a la succión del viento de sistemas innovadores de tejados con tejas cerámicas. Evaluación técnica preliminar
Building & Management
innovative roofing kit
technical assessment
ceramic tiles
wind uplift
sistema innovador de cubierta
evaluación técnica
tejas cerámicas
succión de viento
author_facet Eduardo Lahoz Ruiz
author_sort Eduardo Lahoz Ruiz
title Wind suction resistance of innovative roofing kits based on ceramic tiles. A preliminar technical assessment = Resistencia a la succión del viento de sistemas innovadores de tejados con tejas cerámicas. Evaluación técnica preliminar
title_short Wind suction resistance of innovative roofing kits based on ceramic tiles. A preliminar technical assessment = Resistencia a la succión del viento de sistemas innovadores de tejados con tejas cerámicas. Evaluación técnica preliminar
title_full Wind suction resistance of innovative roofing kits based on ceramic tiles. A preliminar technical assessment = Resistencia a la succión del viento de sistemas innovadores de tejados con tejas cerámicas. Evaluación técnica preliminar
title_fullStr Wind suction resistance of innovative roofing kits based on ceramic tiles. A preliminar technical assessment = Resistencia a la succión del viento de sistemas innovadores de tejados con tejas cerámicas. Evaluación técnica preliminar
title_full_unstemmed Wind suction resistance of innovative roofing kits based on ceramic tiles. A preliminar technical assessment = Resistencia a la succión del viento de sistemas innovadores de tejados con tejas cerámicas. Evaluación técnica preliminar
title_sort wind suction resistance of innovative roofing kits based on ceramic tiles. a preliminar technical assessment = resistencia a la succión del viento de sistemas innovadores de tejados con tejas cerámicas. evaluación técnica preliminar
publisher Universidad Politécnica de Madrid
series Building & Management
issn 2530-8157
publishDate 2019-12-01
description DuPitched roof based on tiles avoid wind uplift by providing and adequate mechanically fixing pattern to support. This goal should be achieved according to specifications and zoning maps from the installation standard for ceramic tiles roofs UNE 136020 recognized by Basic Document CTE DB-HS-1 for ceramic tiles roofing. Nevertheless, this Document and DB-SE-AE refers to an updated and different map for the calculation of wind actions for façades. In this incoherent regulation context, new full-dry installed innovative roofing kits require of a preliminary and faster procedure for technical assessment regarding its fitness for use. This scope requires focusing firstly on the most critical requirement, Safety, considering only its wind uplift behaviour. For this purpose, once objectives were defined, the State of the Art analyzed, an experimental study was carried out regarding pull out test of fixing tiles screws to profiles and wind uplift of kit according to EN 14437, completed with worksite inspection. The results lead to the principal conclusion: It was feasible to carry out a preliminary and partial technical evaluation of fitness for use of roofing kits based on the contribution to compliance with the basic safety requirement by determining the resistance to wind suction considering the application of the DB-SE-AE of CTE. Resumen Las cubiertas inclinadas a base de tejas evitan su levantamiento por el viento mediante un adecuado patrón de fijación mecánica a su elemento soporte. Este objetivo se alcanzaría cumpliendo las especificaciones del texto y mapas de datos de la Norma UNE 136020, para montaje de tejados con tejas cerámicas, reconocida por el Documento Básico del CTE DB-HS-1. Sin embargo, este mismo documento considera otros criterios de cálculo y mapas de datos diferentes para fachadas. En este incoherente contexto normativo, nuevos sistemas innovadores de tejados a base de tejas instalados totalmente en seco, requieren de un procedimiento preliminar y rápido para la evaluación técnica de su aptitud de empleo. Este objetivo supone dirigirse en primer lugar hacia la evaluación de la exigencia más crítica, la Seguridad, considerando únicamente el comportamiento frente a la succión del viento del sistema. Para este fin, una vez definidos los objetivos y analizado el estado del conocimiento, se realizó un estudio experimental relativao a la resistencia al arrancamiento del tornillo que fija la teja al rastrel así como del comportamiento del sistema frente a la succión del viento según los procedimientos de la Norma UNE EN 14437, completado con una visita previa de obra. Se concluyó que sí era viable realizar una evaluación técnica preliminar y favorable de la idoneidad de empleo de un sistema innovador de cubiertas, centrándose en la contribución a la Seguridad, considerando la aplicación del CTE-DB-SE-AE.
topic innovative roofing kit
technical assessment
ceramic tiles
wind uplift
sistema innovador de cubierta
evaluación técnica
tejas cerámicas
succión de viento
url http://polired.upm.es/index.php/building_management/article/view/4036
work_keys_str_mv AT eduardolahozruiz windsuctionresistanceofinnovativeroofingkitsbasedonceramictilesapreliminartechnicalassessmentresistenciaalasucciondelvientodesistemasinnovadoresdetejadoscontejasceramicasevaluaciontecnicapreliminar
_version_ 1725094117708398592