Jigless knotless internal brace technique for acute Achilles tendon rupture: a case series study

Abstract Purpose To mitigate the risk of poor wound healing and of infection associated with the open repair of Achilles tendon midsubstance ruptures, minimally invasive techniques have been developed. We report our preliminary results after reviewing our “jigless knotless internal brace technique.”...

Full description

Bibliographic Details
Main Authors: Po-Yen Ko, Ming-Tung Huang, Chia-Lung Li, Wei-Ren Su, I-Ming Jou, Po-Ting Wu
Format: Article
Language:English
Published: BMC 2019-12-01
Series:Journal of Orthopaedic Surgery and Research
Subjects:
Online Access:https://doi.org/10.1186/s13018-019-1471-8
id doaj-c5c5626e8ace455cb077049f8ec12973
record_format Article
spelling doaj-c5c5626e8ace455cb077049f8ec129732020-12-06T12:30:05ZengBMCJournal of Orthopaedic Surgery and Research1749-799X2019-12-011411810.1186/s13018-019-1471-8Jigless knotless internal brace technique for acute Achilles tendon rupture: a case series studyPo-Yen Ko0Ming-Tung Huang1Chia-Lung Li2Wei-Ren Su3I-Ming Jou4Po-Ting Wu5Department of Biomedical Engineering, National Cheng Kung UniversityDepartment of Orthopedics, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung UniversityDepartment of Orthopedics, National Cheng Kung University Hospital Dou-Liu Branch, College of Medicine, National Cheng Kung UniversityDepartment of Orthopedics, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung UniversityDepartment of Orthopedics, E-Da HospitalDepartment of Biomedical Engineering, National Cheng Kung UniversityAbstract Purpose To mitigate the risk of poor wound healing and of infection associated with the open repair of Achilles tendon midsubstance ruptures, minimally invasive techniques have been developed. We report our preliminary results after reviewing our “jigless knotless internal brace technique.” Methods Patients were placed in prone position and a transverse 3-cm incision was made proximal to the palpable ruptured end. The proximal ruptured end was pulled out, gently debrided, and sutured using Krackow locking loops. Percutaneous sutures were crisscrossed through the distal tendon stump and looped around the Krackow sutures over the proximal stump. The ipsilateral Krackow sutures and the contralateral crisscrossed sutures were subcutaneously passed through two mini-incisions over the posterior calcaneus tuberosity and seated at the tuberosity with two 4.5-mm knotless suture anchors. All patients underwent the same post-operative rehabilitation protocol and regular follow-ups for at least 1 year. Results We recruited 10 patients (mean age, 37.3 years) who scored 100 points on the American Orthopaedic Foot and Ankle Society (AOFAS) scale, and who returned to their preoperative exercise levels 1-year post-operatively with no complications. Conclusion Our method is simple, effective, and requires no special tools. It might be a reliable option for Achilles tendon repair. Level of evidence IIIhttps://doi.org/10.1186/s13018-019-1471-8Achilles tendon ruptureMinimally invasiveKnotlessInternal brace
collection DOAJ
language English
format Article
sources DOAJ
author Po-Yen Ko
Ming-Tung Huang
Chia-Lung Li
Wei-Ren Su
I-Ming Jou
Po-Ting Wu
spellingShingle Po-Yen Ko
Ming-Tung Huang
Chia-Lung Li
Wei-Ren Su
I-Ming Jou
Po-Ting Wu
Jigless knotless internal brace technique for acute Achilles tendon rupture: a case series study
Journal of Orthopaedic Surgery and Research
Achilles tendon rupture
Minimally invasive
Knotless
Internal brace
author_facet Po-Yen Ko
Ming-Tung Huang
Chia-Lung Li
Wei-Ren Su
I-Ming Jou
Po-Ting Wu
author_sort Po-Yen Ko
title Jigless knotless internal brace technique for acute Achilles tendon rupture: a case series study
title_short Jigless knotless internal brace technique for acute Achilles tendon rupture: a case series study
title_full Jigless knotless internal brace technique for acute Achilles tendon rupture: a case series study
title_fullStr Jigless knotless internal brace technique for acute Achilles tendon rupture: a case series study
title_full_unstemmed Jigless knotless internal brace technique for acute Achilles tendon rupture: a case series study
title_sort jigless knotless internal brace technique for acute achilles tendon rupture: a case series study
publisher BMC
series Journal of Orthopaedic Surgery and Research
issn 1749-799X
publishDate 2019-12-01
description Abstract Purpose To mitigate the risk of poor wound healing and of infection associated with the open repair of Achilles tendon midsubstance ruptures, minimally invasive techniques have been developed. We report our preliminary results after reviewing our “jigless knotless internal brace technique.” Methods Patients were placed in prone position and a transverse 3-cm incision was made proximal to the palpable ruptured end. The proximal ruptured end was pulled out, gently debrided, and sutured using Krackow locking loops. Percutaneous sutures were crisscrossed through the distal tendon stump and looped around the Krackow sutures over the proximal stump. The ipsilateral Krackow sutures and the contralateral crisscrossed sutures were subcutaneously passed through two mini-incisions over the posterior calcaneus tuberosity and seated at the tuberosity with two 4.5-mm knotless suture anchors. All patients underwent the same post-operative rehabilitation protocol and regular follow-ups for at least 1 year. Results We recruited 10 patients (mean age, 37.3 years) who scored 100 points on the American Orthopaedic Foot and Ankle Society (AOFAS) scale, and who returned to their preoperative exercise levels 1-year post-operatively with no complications. Conclusion Our method is simple, effective, and requires no special tools. It might be a reliable option for Achilles tendon repair. Level of evidence III
topic Achilles tendon rupture
Minimally invasive
Knotless
Internal brace
url https://doi.org/10.1186/s13018-019-1471-8
work_keys_str_mv AT poyenko jiglessknotlessinternalbracetechniqueforacuteachillestendonruptureacaseseriesstudy
AT mingtunghuang jiglessknotlessinternalbracetechniqueforacuteachillestendonruptureacaseseriesstudy
AT chialungli jiglessknotlessinternalbracetechniqueforacuteachillestendonruptureacaseseriesstudy
AT weirensu jiglessknotlessinternalbracetechniqueforacuteachillestendonruptureacaseseriesstudy
AT imingjou jiglessknotlessinternalbracetechniqueforacuteachillestendonruptureacaseseriesstudy
AT potingwu jiglessknotlessinternalbracetechniqueforacuteachillestendonruptureacaseseriesstudy
_version_ 1724398783519784960