Clinical performance of ICDAS II, radiovisiography, and alternating current impedance spectroscopy device for the detection and assessment of occlusal caries in primary molars

Objective: To investigate the clinical performance of International Caries Detection and Assessment System II (ICDAS II) (a ranked visual scale), radiovisiography (RVG) (a digital radiography device), and an alternating current impedance spectroscopy (ACIS) device for the detection and assessment of...

Full description

Bibliographic Details
Main Authors: Rohit Singh, Shobha Tandon, Monika Rathore, Nitesh Tewari, Neha Singh, Abhinav Pradeep Shitoot
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2016-01-01
Series:Journal of Indian Society of Pedodontics and Preventive Dentistry
Subjects:
Online Access:http://www.jisppd.com/article.asp?issn=0970-4388;year=2016;volume=34;issue=2;spage=152;epage=158;aulast=Singh
id doaj-c5bf96c7a447455a8763844d2146ca13
record_format Article
spelling doaj-c5bf96c7a447455a8763844d2146ca132020-11-24T22:24:38ZengWolters Kluwer Medknow PublicationsJournal of Indian Society of Pedodontics and Preventive Dentistry0970-43881998-39052016-01-0134215215810.4103/0970-4388.180445Clinical performance of ICDAS II, radiovisiography, and alternating current impedance spectroscopy device for the detection and assessment of occlusal caries in primary molarsRohit SinghShobha TandonMonika RathoreNitesh TewariNeha SinghAbhinav Pradeep ShitootObjective: To investigate the clinical performance of International Caries Detection and Assessment System II (ICDAS II) (a ranked visual scale), radiovisiography (RVG) (a digital radiography device), and an alternating current impedance spectroscopy (ACIS) device for the detection and assessment of occlusal caries in primary teeth. Materials and Methods: Twenty-five molars were assessed using all three systems under standardized in vivo conditions. They were then extracted and also assessed by examiners in vitro. Downer′s histological scoring criterion was the validation gold standard. Sensitivity, specificity, positive and negative likelihood ratios, and area under the receiver-operator curves were calculated for enamel caries and dentine caries. Repeatability was analyzed using intraclass correlation coefficient (ICC). The performances of the systems between in vivo and in vitro settings by the same examiner were also compared. Statistical Analysis: SPSS version 17.0 (SPSS Inc., Chicago, IL, USA) was used to analyze the data. Comparison of the performance of all three systems for all caries and dentine caries using receiver operating characteristic curves was calculated using a range of cutoffs. Reliability was assessed using ICC method. Results: ICDAS II system showed the highest validity and repeatability for assessing occlusal caries in the primary molars. RVG was less accurate than the ICDAS II for detecting caries lesions confined to enamel. However, when dentine was involved, RVG was found to be as effective as ICDAS II. Conclusion: Within the limitations of the study, the in vivo results of ICDAS II and RVG were satisfactory and comparable to those obtained in vitro, with ICDAS II performing better. The ACIS device was least accurate among the three systems for caries assessment.http://www.jisppd.com/article.asp?issn=0970-4388;year=2016;volume=34;issue=2;spage=152;epage=158;aulast=SinghAlternating current impedance spectroscopy devicecaries detectionInternational Caries Detection and Assessment System IIprimary molarradiovisiography
collection DOAJ
language English
format Article
sources DOAJ
author Rohit Singh
Shobha Tandon
Monika Rathore
Nitesh Tewari
Neha Singh
Abhinav Pradeep Shitoot
spellingShingle Rohit Singh
Shobha Tandon
Monika Rathore
Nitesh Tewari
Neha Singh
Abhinav Pradeep Shitoot
Clinical performance of ICDAS II, radiovisiography, and alternating current impedance spectroscopy device for the detection and assessment of occlusal caries in primary molars
Journal of Indian Society of Pedodontics and Preventive Dentistry
Alternating current impedance spectroscopy device
caries detection
International Caries Detection and Assessment System II
primary molar
radiovisiography
author_facet Rohit Singh
Shobha Tandon
Monika Rathore
Nitesh Tewari
Neha Singh
Abhinav Pradeep Shitoot
author_sort Rohit Singh
title Clinical performance of ICDAS II, radiovisiography, and alternating current impedance spectroscopy device for the detection and assessment of occlusal caries in primary molars
title_short Clinical performance of ICDAS II, radiovisiography, and alternating current impedance spectroscopy device for the detection and assessment of occlusal caries in primary molars
title_full Clinical performance of ICDAS II, radiovisiography, and alternating current impedance spectroscopy device for the detection and assessment of occlusal caries in primary molars
title_fullStr Clinical performance of ICDAS II, radiovisiography, and alternating current impedance spectroscopy device for the detection and assessment of occlusal caries in primary molars
title_full_unstemmed Clinical performance of ICDAS II, radiovisiography, and alternating current impedance spectroscopy device for the detection and assessment of occlusal caries in primary molars
title_sort clinical performance of icdas ii, radiovisiography, and alternating current impedance spectroscopy device for the detection and assessment of occlusal caries in primary molars
publisher Wolters Kluwer Medknow Publications
series Journal of Indian Society of Pedodontics and Preventive Dentistry
issn 0970-4388
1998-3905
publishDate 2016-01-01
description Objective: To investigate the clinical performance of International Caries Detection and Assessment System II (ICDAS II) (a ranked visual scale), radiovisiography (RVG) (a digital radiography device), and an alternating current impedance spectroscopy (ACIS) device for the detection and assessment of occlusal caries in primary teeth. Materials and Methods: Twenty-five molars were assessed using all three systems under standardized in vivo conditions. They were then extracted and also assessed by examiners in vitro. Downer′s histological scoring criterion was the validation gold standard. Sensitivity, specificity, positive and negative likelihood ratios, and area under the receiver-operator curves were calculated for enamel caries and dentine caries. Repeatability was analyzed using intraclass correlation coefficient (ICC). The performances of the systems between in vivo and in vitro settings by the same examiner were also compared. Statistical Analysis: SPSS version 17.0 (SPSS Inc., Chicago, IL, USA) was used to analyze the data. Comparison of the performance of all three systems for all caries and dentine caries using receiver operating characteristic curves was calculated using a range of cutoffs. Reliability was assessed using ICC method. Results: ICDAS II system showed the highest validity and repeatability for assessing occlusal caries in the primary molars. RVG was less accurate than the ICDAS II for detecting caries lesions confined to enamel. However, when dentine was involved, RVG was found to be as effective as ICDAS II. Conclusion: Within the limitations of the study, the in vivo results of ICDAS II and RVG were satisfactory and comparable to those obtained in vitro, with ICDAS II performing better. The ACIS device was least accurate among the three systems for caries assessment.
topic Alternating current impedance spectroscopy device
caries detection
International Caries Detection and Assessment System II
primary molar
radiovisiography
url http://www.jisppd.com/article.asp?issn=0970-4388;year=2016;volume=34;issue=2;spage=152;epage=158;aulast=Singh
work_keys_str_mv AT rohitsingh clinicalperformanceoficdasiiradiovisiographyandalternatingcurrentimpedancespectroscopydeviceforthedetectionandassessmentofocclusalcariesinprimarymolars
AT shobhatandon clinicalperformanceoficdasiiradiovisiographyandalternatingcurrentimpedancespectroscopydeviceforthedetectionandassessmentofocclusalcariesinprimarymolars
AT monikarathore clinicalperformanceoficdasiiradiovisiographyandalternatingcurrentimpedancespectroscopydeviceforthedetectionandassessmentofocclusalcariesinprimarymolars
AT niteshtewari clinicalperformanceoficdasiiradiovisiographyandalternatingcurrentimpedancespectroscopydeviceforthedetectionandassessmentofocclusalcariesinprimarymolars
AT nehasingh clinicalperformanceoficdasiiradiovisiographyandalternatingcurrentimpedancespectroscopydeviceforthedetectionandassessmentofocclusalcariesinprimarymolars
AT abhinavpradeepshitoot clinicalperformanceoficdasiiradiovisiographyandalternatingcurrentimpedancespectroscopydeviceforthedetectionandassessmentofocclusalcariesinprimarymolars
_version_ 1725760395483807744