Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross Section

The use of elbow or curved pipe in the installation of piping has a loss of pressure (pressure drop) which could lead the power of pump that drive the fluid and decrease the energy efficiency of the system. The pressure drop is caused by the curved shape of the elbow that cause pressure on the oute...

Full description

Bibliographic Details
Main Authors: Setyo Nugroho, Achmad Arifudin Hidayatulloh
Format: Article
Language:English
Published: Politeknik Elektronika Negeri Surabaya 2016-12-01
Series:Emitter: International Journal of Engineering Technology
Subjects:
Online Access:http://emitter2.pens.ac.id/ojs/index.php/emitter/article/view/157
id doaj-c5768da119a1406fb6f4b83937d8c6bc
record_format Article
spelling doaj-c5768da119a1406fb6f4b83937d8c6bc2021-02-09T08:51:23ZengPoliteknik Elektronika Negeri Surabaya Emitter: International Journal of Engineering Technology2355-391X2443-11682016-12-014210.24003/emitter.v4i2.157Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross SectionSetyo Nugroho0Achmad Arifudin Hidayatulloh1Politeknik Elektronika Negeri SurabayaPoliteknik Elektronika Negeri Surabaya The use of elbow or curved pipe in the installation of piping has a loss of pressure (pressure drop) which could lead the power of pump that drive the fluid and decrease the energy efficiency of the system. The pressure drop is caused by the curved shape of the elbow that cause pressure on the outer wall (outter) larger and blocking off the pace of the fluid, and flow pressure losses caused by friction, flow separation and secondary flow. A method that can be used to reduce flow separation and pressure loss in the elbow is by the insertion guide vane. The test model in the form of rectangular elbow 900  with a radius ratio (rc/Dh) = 1.1249 without using a guide vane and number of guide vane insertion one until three guide vanes. With Reynolds number ReDh ≈ 8.6 × 104. The velocity inlet is uniform, the measured variable is static pressure. Static pressure was measured using an inclined manometer. With variation the number of guide vane gives a more effect on the value of pressure drop, the largest pressure drop until 123.35% compared to that without guide vane. The velocity distribution profile on the outlet side becomes more uniform. The magnitude of this pressure drop occurs as a result of the increased flow friction and its secondary flow become smaller. http://emitter2.pens.ac.id/ojs/index.php/emitter/article/view/157Rectangular elbow 900guide vanepressure dropsecondary flow
collection DOAJ
language English
format Article
sources DOAJ
author Setyo Nugroho
Achmad Arifudin Hidayatulloh
spellingShingle Setyo Nugroho
Achmad Arifudin Hidayatulloh
Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross Section
Emitter: International Journal of Engineering Technology
Rectangular elbow 900
guide vane
pressure drop
secondary flow
author_facet Setyo Nugroho
Achmad Arifudin Hidayatulloh
author_sort Setyo Nugroho
title Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross Section
title_short Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross Section
title_full Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross Section
title_fullStr Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross Section
title_full_unstemmed Performance Analysis of The Effect on Insertion Guide Vanes For Rectangular Elbow 900 Cross Section
title_sort performance analysis of the effect on insertion guide vanes for rectangular elbow 900 cross section
publisher Politeknik Elektronika Negeri Surabaya
series Emitter: International Journal of Engineering Technology
issn 2355-391X
2443-1168
publishDate 2016-12-01
description The use of elbow or curved pipe in the installation of piping has a loss of pressure (pressure drop) which could lead the power of pump that drive the fluid and decrease the energy efficiency of the system. The pressure drop is caused by the curved shape of the elbow that cause pressure on the outer wall (outter) larger and blocking off the pace of the fluid, and flow pressure losses caused by friction, flow separation and secondary flow. A method that can be used to reduce flow separation and pressure loss in the elbow is by the insertion guide vane. The test model in the form of rectangular elbow 900  with a radius ratio (rc/Dh) = 1.1249 without using a guide vane and number of guide vane insertion one until three guide vanes. With Reynolds number ReDh ≈ 8.6 × 104. The velocity inlet is uniform, the measured variable is static pressure. Static pressure was measured using an inclined manometer. With variation the number of guide vane gives a more effect on the value of pressure drop, the largest pressure drop until 123.35% compared to that without guide vane. The velocity distribution profile on the outlet side becomes more uniform. The magnitude of this pressure drop occurs as a result of the increased flow friction and its secondary flow become smaller.
topic Rectangular elbow 900
guide vane
pressure drop
secondary flow
url http://emitter2.pens.ac.id/ojs/index.php/emitter/article/view/157
work_keys_str_mv AT setyonugroho performanceanalysisoftheeffectoninsertionguidevanesforrectangularelbow900crosssection
AT achmadarifudinhidayatulloh performanceanalysisoftheeffectoninsertionguidevanesforrectangularelbow900crosssection
_version_ 1724277534402543616