The effectiveness of new technologies implementation in the surgical treatment of cereberal fractures of femur

Aim. Fractures of the proximal femur and their consequences every year cause enormous damage to the economy of any state. Despite the latest achievements of modern traumatology, quite high percentage (10 %) of unsatisfactory results of surgical treatment of cereberal fractures of the femur in pati...

Full description

Bibliographic Details
Main Authors: A. V. Kalashikov, V. D. Malik, О. V. Kalashnikov
Format: Article
Language:English
Published: Zaporozhye State Medical University 2016-08-01
Series:Aktualʹnì Pitannâ Farmacevtičnoï ì Medičnoï Nauki ta Praktiki
Subjects:
Online Access:http://pharmed.zsmu.edu.ua/article/view/70900/67982
id doaj-c555d2c83b40405485a0260df63e3cc5
record_format Article
spelling doaj-c555d2c83b40405485a0260df63e3cc52020-11-25T02:09:39ZengZaporozhye State Medical UniversityAktualʹnì Pitannâ Farmacevtičnoï ì Medičnoï Nauki ta Praktiki2306-80942409-29322016-08-012747810.14739/2409-2932.2016.2.70900The effectiveness of new technologies implementation in the surgical treatment of cereberal fractures of femurA. V. KalashikovV. D. MalikО. V. Kalashnikov Aim. Fractures of the proximal femur and their consequences every year cause enormous damage to the economy of any state. Despite the latest achievements of modern traumatology, quite high percentage (10 %) of unsatisfactory results of surgical treatment of cereberal fractures of the femur in patients remains present. Obtained postoperative complications usually lead to the re-operative intervention (total hip replacement). The authors developed a distal locking method of the intramedullary rod with cereberal fractures of the femur, depending on its type according to the classification of AO. This method applies for a patent of Ukraine for useful model. For fractures of type A1 according to the developed method of vertical stability provides intramedullary rod itself and needs no distal locking; only proximal blocking is done. For fractures of type A3 blocking is made with the help of one distal locking screw, which is introduced into the oval hole. Implementation of the proposed method allows to create micromotion in the system "bone - rod," contributs to optimization of reparative osteosynthesis and reduces the trauma of surgical intervention. The aim of the study was to determine the effectiveness of the implementation of new technologies in the surgical treatment of cereberal fractures of femur. Materials and methods. A comprehensive clinical study of 100 patients with ceresville femoral neck fractures who underwent operative intervention – locked intramedullary nailing (LIN) have been done. All patients were divided into two groups, first (control) group consisted of 50 patients with ceresville fractures of the femur who underwent the LIN by conventional methods. The second (experimental) group consisted of 50 patients with ceresville fractures of the femur who underwent the LIN using the new technologies developed by the authors. The effectiveness of treatment in both groups of observation has been researched. The observation period was 1 year. There was statistically significant (p≤ 0.01) decrease in the number of early (2 times) and late (3 times) postoperative complications in patients group where the blocking intramedullary rod were performed biomechanically justified, according to the recommendations developed by the authors, in comparison with patients groups that used conventional methods of LIN. Results. The use of new technologies allows to increase the efficiency in 10 % of surgical treatment of patients with ceresville fractures of the femur. Conclusion. The implementation of proposed new technologies will allow to perform effective differentiated (depending on the type of fracture according to the AO classification), surgical treatment of patients, also to improve the efficiency of medical care to patients with ceresville fractures of the femur, which distinguishes the proposed method from the conventional methods of LIN. http://pharmed.zsmu.edu.ua/article/view/70900/67982Biomedical TechnologyFemoral FracturesTreatment Outcome
collection DOAJ
language English
format Article
sources DOAJ
author A. V. Kalashikov
V. D. Malik
О. V. Kalashnikov
spellingShingle A. V. Kalashikov
V. D. Malik
О. V. Kalashnikov
The effectiveness of new technologies implementation in the surgical treatment of cereberal fractures of femur
Aktualʹnì Pitannâ Farmacevtičnoï ì Medičnoï Nauki ta Praktiki
Biomedical Technology
Femoral Fractures
Treatment Outcome
author_facet A. V. Kalashikov
V. D. Malik
О. V. Kalashnikov
author_sort A. V. Kalashikov
title The effectiveness of new technologies implementation in the surgical treatment of cereberal fractures of femur
title_short The effectiveness of new technologies implementation in the surgical treatment of cereberal fractures of femur
title_full The effectiveness of new technologies implementation in the surgical treatment of cereberal fractures of femur
title_fullStr The effectiveness of new technologies implementation in the surgical treatment of cereberal fractures of femur
title_full_unstemmed The effectiveness of new technologies implementation in the surgical treatment of cereberal fractures of femur
title_sort effectiveness of new technologies implementation in the surgical treatment of cereberal fractures of femur
publisher Zaporozhye State Medical University
series Aktualʹnì Pitannâ Farmacevtičnoï ì Medičnoï Nauki ta Praktiki
issn 2306-8094
2409-2932
publishDate 2016-08-01
description Aim. Fractures of the proximal femur and their consequences every year cause enormous damage to the economy of any state. Despite the latest achievements of modern traumatology, quite high percentage (10 %) of unsatisfactory results of surgical treatment of cereberal fractures of the femur in patients remains present. Obtained postoperative complications usually lead to the re-operative intervention (total hip replacement). The authors developed a distal locking method of the intramedullary rod with cereberal fractures of the femur, depending on its type according to the classification of AO. This method applies for a patent of Ukraine for useful model. For fractures of type A1 according to the developed method of vertical stability provides intramedullary rod itself and needs no distal locking; only proximal blocking is done. For fractures of type A3 blocking is made with the help of one distal locking screw, which is introduced into the oval hole. Implementation of the proposed method allows to create micromotion in the system "bone - rod," contributs to optimization of reparative osteosynthesis and reduces the trauma of surgical intervention. The aim of the study was to determine the effectiveness of the implementation of new technologies in the surgical treatment of cereberal fractures of femur. Materials and methods. A comprehensive clinical study of 100 patients with ceresville femoral neck fractures who underwent operative intervention – locked intramedullary nailing (LIN) have been done. All patients were divided into two groups, first (control) group consisted of 50 patients with ceresville fractures of the femur who underwent the LIN by conventional methods. The second (experimental) group consisted of 50 patients with ceresville fractures of the femur who underwent the LIN using the new technologies developed by the authors. The effectiveness of treatment in both groups of observation has been researched. The observation period was 1 year. There was statistically significant (p≤ 0.01) decrease in the number of early (2 times) and late (3 times) postoperative complications in patients group where the blocking intramedullary rod were performed biomechanically justified, according to the recommendations developed by the authors, in comparison with patients groups that used conventional methods of LIN. Results. The use of new technologies allows to increase the efficiency in 10 % of surgical treatment of patients with ceresville fractures of the femur. Conclusion. The implementation of proposed new technologies will allow to perform effective differentiated (depending on the type of fracture according to the AO classification), surgical treatment of patients, also to improve the efficiency of medical care to patients with ceresville fractures of the femur, which distinguishes the proposed method from the conventional methods of LIN.
topic Biomedical Technology
Femoral Fractures
Treatment Outcome
url http://pharmed.zsmu.edu.ua/article/view/70900/67982
work_keys_str_mv AT avkalashikov theeffectivenessofnewtechnologiesimplementationinthesurgicaltreatmentofcereberalfracturesoffemur
AT vdmalik theeffectivenessofnewtechnologiesimplementationinthesurgicaltreatmentofcereberalfracturesoffemur
AT ovkalashnikov theeffectivenessofnewtechnologiesimplementationinthesurgicaltreatmentofcereberalfracturesoffemur
AT avkalashikov effectivenessofnewtechnologiesimplementationinthesurgicaltreatmentofcereberalfracturesoffemur
AT vdmalik effectivenessofnewtechnologiesimplementationinthesurgicaltreatmentofcereberalfracturesoffemur
AT ovkalashnikov effectivenessofnewtechnologiesimplementationinthesurgicaltreatmentofcereberalfracturesoffemur
_version_ 1724922410069655552