High spatio-temporal-resolution detection of chlorophyll fluorescence dynamics from a single chloroplast with confocal imaging fluorometer

Abstract Background Chlorophyll fluorescence (CF) is a key indicator to study plant physiology or photosynthesis efficiency. Conventionally, CF is characterized by fluorometers, which only allows ensemble measurement through wide-field detection. For imaging fluorometers, the typical spatial and tem...

Full description

Bibliographic Details
Main Authors: Yi-Chin Tseng, Shi-Wei Chu
Format: Article
Language:English
Published: BMC 2017-05-01
Series:Plant Methods
Subjects:
Online Access:http://link.springer.com/article/10.1186/s13007-017-0194-2
id doaj-c4afa2d03d0f45bd87bc4afa2259fbee
record_format Article
spelling doaj-c4afa2d03d0f45bd87bc4afa2259fbee2020-11-25T00:39:56ZengBMCPlant Methods1746-48112017-05-0113111110.1186/s13007-017-0194-2High spatio-temporal-resolution detection of chlorophyll fluorescence dynamics from a single chloroplast with confocal imaging fluorometerYi-Chin Tseng0Shi-Wei Chu1Department of Physics, National Taiwan UniversityDepartment of Physics, National Taiwan UniversityAbstract Background Chlorophyll fluorescence (CF) is a key indicator to study plant physiology or photosynthesis efficiency. Conventionally, CF is characterized by fluorometers, which only allows ensemble measurement through wide-field detection. For imaging fluorometers, the typical spatial and temporal resolutions are on the order of millimeter and second, far from enough to study cellular/sub-cellular CF dynamics. In addition, due to the lack of optical sectioning capability, conventional imaging fluorometers cannot identify CF from a single cell or even a single chloroplast. Results and discussion Here we demonstrated a fluorometer based on confocal imaging, that not only provides high contrast images, but also allows CF measurement with spatiotemporal resolution as high as micrometer and millisecond. CF transient (the Kautsky curve) from a single chloroplast is successfully obtained, with both the temporal dynamics and the intensity dependences corresponding well to the ensemble measurement from conventional studies. The significance of confocal imaging fluorometer is to identify the variation among individual chloroplasts, e.g. the temporal position of the P–S–M phases, and the half-life period of P–T decay in the Kautsky curve, that are not possible to analyze with wide-field techniques. A linear relationship is found between excitation intensity and the temporal positions of P–S–M peaks/valleys in the Kautsky curve. Based on the CF transients, the photosynthetic quantum efficiency is derived with spatial resolution down to a single chloroplast. In addition, an interesting 6-order increase in excitation intensity is found between wide-field and confocal fluorometers, whose pixel integration time and optical sectioning may account for this substantial difference. Conclusion Confocal imaging fluorometers provide micrometer and millisecond CF characterization, opening up unprecedented possibilities toward detailed spatiotemporal analysis of CF transients and its propagation dynamics, as well as photosynthesis efficiency analysis, on the scale of organelles, in a living plant.http://link.springer.com/article/10.1186/s13007-017-0194-2Optical section3D microscopyKautsky curveChlorophyll fluorescence transient
collection DOAJ
language English
format Article
sources DOAJ
author Yi-Chin Tseng
Shi-Wei Chu
spellingShingle Yi-Chin Tseng
Shi-Wei Chu
High spatio-temporal-resolution detection of chlorophyll fluorescence dynamics from a single chloroplast with confocal imaging fluorometer
Plant Methods
Optical section
3D microscopy
Kautsky curve
Chlorophyll fluorescence transient
author_facet Yi-Chin Tseng
Shi-Wei Chu
author_sort Yi-Chin Tseng
title High spatio-temporal-resolution detection of chlorophyll fluorescence dynamics from a single chloroplast with confocal imaging fluorometer
title_short High spatio-temporal-resolution detection of chlorophyll fluorescence dynamics from a single chloroplast with confocal imaging fluorometer
title_full High spatio-temporal-resolution detection of chlorophyll fluorescence dynamics from a single chloroplast with confocal imaging fluorometer
title_fullStr High spatio-temporal-resolution detection of chlorophyll fluorescence dynamics from a single chloroplast with confocal imaging fluorometer
title_full_unstemmed High spatio-temporal-resolution detection of chlorophyll fluorescence dynamics from a single chloroplast with confocal imaging fluorometer
title_sort high spatio-temporal-resolution detection of chlorophyll fluorescence dynamics from a single chloroplast with confocal imaging fluorometer
publisher BMC
series Plant Methods
issn 1746-4811
publishDate 2017-05-01
description Abstract Background Chlorophyll fluorescence (CF) is a key indicator to study plant physiology or photosynthesis efficiency. Conventionally, CF is characterized by fluorometers, which only allows ensemble measurement through wide-field detection. For imaging fluorometers, the typical spatial and temporal resolutions are on the order of millimeter and second, far from enough to study cellular/sub-cellular CF dynamics. In addition, due to the lack of optical sectioning capability, conventional imaging fluorometers cannot identify CF from a single cell or even a single chloroplast. Results and discussion Here we demonstrated a fluorometer based on confocal imaging, that not only provides high contrast images, but also allows CF measurement with spatiotemporal resolution as high as micrometer and millisecond. CF transient (the Kautsky curve) from a single chloroplast is successfully obtained, with both the temporal dynamics and the intensity dependences corresponding well to the ensemble measurement from conventional studies. The significance of confocal imaging fluorometer is to identify the variation among individual chloroplasts, e.g. the temporal position of the P–S–M phases, and the half-life period of P–T decay in the Kautsky curve, that are not possible to analyze with wide-field techniques. A linear relationship is found between excitation intensity and the temporal positions of P–S–M peaks/valleys in the Kautsky curve. Based on the CF transients, the photosynthetic quantum efficiency is derived with spatial resolution down to a single chloroplast. In addition, an interesting 6-order increase in excitation intensity is found between wide-field and confocal fluorometers, whose pixel integration time and optical sectioning may account for this substantial difference. Conclusion Confocal imaging fluorometers provide micrometer and millisecond CF characterization, opening up unprecedented possibilities toward detailed spatiotemporal analysis of CF transients and its propagation dynamics, as well as photosynthesis efficiency analysis, on the scale of organelles, in a living plant.
topic Optical section
3D microscopy
Kautsky curve
Chlorophyll fluorescence transient
url http://link.springer.com/article/10.1186/s13007-017-0194-2
work_keys_str_mv AT yichintseng highspatiotemporalresolutiondetectionofchlorophyllfluorescencedynamicsfromasinglechloroplastwithconfocalimagingfluorometer
AT shiweichu highspatiotemporalresolutiondetectionofchlorophyllfluorescencedynamicsfromasinglechloroplastwithconfocalimagingfluorometer
_version_ 1725292301965590528