Comparative analysis of the Equivital EQ02 lifemonitor with Holter ambulatory ECG device for continuous measurement of ECG, heart rate and heart rate variability: A validation study for precision and accuracy.

Background: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR and HRV, respiration, activity and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously mon...

Full description

Bibliographic Details
Main Authors: Abimbola A. Akintola, Vera van de Pol, Daniel Bimmel, Arie C. Maan, Diana Van Heemst
Format: Article
Language:English
Published: Frontiers Media S.A. 2016-09-01
Series:Frontiers in Physiology
Subjects:
ECG
Online Access:http://journal.frontiersin.org/Journal/10.3389/fphys.2016.00391/full
id doaj-c48702e244204a56a8193d3e35cba341
record_format Article
spelling doaj-c48702e244204a56a8193d3e35cba3412020-11-24T23:19:34ZengFrontiers Media S.A.Frontiers in Physiology1664-042X2016-09-01710.3389/fphys.2016.00391213365Comparative analysis of the Equivital EQ02 lifemonitor with Holter ambulatory ECG device for continuous measurement of ECG, heart rate and heart rate variability: A validation study for precision and accuracy.Abimbola A. Akintola0Vera van de Pol1Daniel Bimmel2Arie C. Maan3Diana Van Heemst4Leiden university medical centerLeiden university medical centerLeiden university medical centerLeiden University Medical Center,Leiden university medical centerBackground: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR and HRV, respiration, activity and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously monitors ECG via electrodes interwoven in the textile of a wearable belt.Objective: To compare EQ02 with the Holter for continuous home measurement of ECG, heart rate (HR) and heart rate variability (HRV).Methods: Eighteen healthy participants wore, simultaneously for 24 hours, the Holter and EQ02 monitors. Per participant, averaged HR and HRV per 5 minutes from the two devices were compared using Pearson correlation, paired T-test and Blant-Altman analyses. Accuracy and precision metrics included mean absolute relative difference (MARD). Results: Artefact content of EQ02 data varied widely between (range 1.93% to 56.45%) and within (range 0.75% to 99.61%) participants. Comparing the EQ02 to the Holter, the Pearson correlations were respectively 0.724, 0.955 and 0.997 for datasets containing all data and data with <50% or <20% artefacts respectively. For datasets containing respectively all data, data with <50% or <20% artefacts, bias estimated by Bland-Altman analysis was -2.8, -1.0 and -0.8 beats per minute and 24h MARD was 7.08, 3.01 and 1.5. After selecting a three- hour stretch of data containing 1.15% artefacts, Pearson correlation was 0.786 for HRV measured as standard deviation of NN intervals (SDNN). Conclusions:Although the EQ02 can accurately measure ECG and HRV, its accuracy and precision is highly dependent on artefact content. This is a serious limitation for clinical use in individual patients. However, the advantages of the EQ02 (ability to simultaneously monitor several physiologic parameters) may outweigh its disadvantages (higher artefact load) for research purposes and/ or for home monitoring in larger groups of study participants. Further studies can be aimed at minimizing the artefacts.http://journal.frontiersin.org/Journal/10.3389/fphys.2016.00391/fullHeart RateECG artifact processingECGremote monitoringValidation studyheart rate variability (HRV)
collection DOAJ
language English
format Article
sources DOAJ
author Abimbola A. Akintola
Vera van de Pol
Daniel Bimmel
Arie C. Maan
Diana Van Heemst
spellingShingle Abimbola A. Akintola
Vera van de Pol
Daniel Bimmel
Arie C. Maan
Diana Van Heemst
Comparative analysis of the Equivital EQ02 lifemonitor with Holter ambulatory ECG device for continuous measurement of ECG, heart rate and heart rate variability: A validation study for precision and accuracy.
Frontiers in Physiology
Heart Rate
ECG artifact processing
ECG
remote monitoring
Validation study
heart rate variability (HRV)
author_facet Abimbola A. Akintola
Vera van de Pol
Daniel Bimmel
Arie C. Maan
Diana Van Heemst
author_sort Abimbola A. Akintola
title Comparative analysis of the Equivital EQ02 lifemonitor with Holter ambulatory ECG device for continuous measurement of ECG, heart rate and heart rate variability: A validation study for precision and accuracy.
title_short Comparative analysis of the Equivital EQ02 lifemonitor with Holter ambulatory ECG device for continuous measurement of ECG, heart rate and heart rate variability: A validation study for precision and accuracy.
title_full Comparative analysis of the Equivital EQ02 lifemonitor with Holter ambulatory ECG device for continuous measurement of ECG, heart rate and heart rate variability: A validation study for precision and accuracy.
title_fullStr Comparative analysis of the Equivital EQ02 lifemonitor with Holter ambulatory ECG device for continuous measurement of ECG, heart rate and heart rate variability: A validation study for precision and accuracy.
title_full_unstemmed Comparative analysis of the Equivital EQ02 lifemonitor with Holter ambulatory ECG device for continuous measurement of ECG, heart rate and heart rate variability: A validation study for precision and accuracy.
title_sort comparative analysis of the equivital eq02 lifemonitor with holter ambulatory ecg device for continuous measurement of ecg, heart rate and heart rate variability: a validation study for precision and accuracy.
publisher Frontiers Media S.A.
series Frontiers in Physiology
issn 1664-042X
publishDate 2016-09-01
description Background: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR and HRV, respiration, activity and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously monitors ECG via electrodes interwoven in the textile of a wearable belt.Objective: To compare EQ02 with the Holter for continuous home measurement of ECG, heart rate (HR) and heart rate variability (HRV).Methods: Eighteen healthy participants wore, simultaneously for 24 hours, the Holter and EQ02 monitors. Per participant, averaged HR and HRV per 5 minutes from the two devices were compared using Pearson correlation, paired T-test and Blant-Altman analyses. Accuracy and precision metrics included mean absolute relative difference (MARD). Results: Artefact content of EQ02 data varied widely between (range 1.93% to 56.45%) and within (range 0.75% to 99.61%) participants. Comparing the EQ02 to the Holter, the Pearson correlations were respectively 0.724, 0.955 and 0.997 for datasets containing all data and data with <50% or <20% artefacts respectively. For datasets containing respectively all data, data with <50% or <20% artefacts, bias estimated by Bland-Altman analysis was -2.8, -1.0 and -0.8 beats per minute and 24h MARD was 7.08, 3.01 and 1.5. After selecting a three- hour stretch of data containing 1.15% artefacts, Pearson correlation was 0.786 for HRV measured as standard deviation of NN intervals (SDNN). Conclusions:Although the EQ02 can accurately measure ECG and HRV, its accuracy and precision is highly dependent on artefact content. This is a serious limitation for clinical use in individual patients. However, the advantages of the EQ02 (ability to simultaneously monitor several physiologic parameters) may outweigh its disadvantages (higher artefact load) for research purposes and/ or for home monitoring in larger groups of study participants. Further studies can be aimed at minimizing the artefacts.
topic Heart Rate
ECG artifact processing
ECG
remote monitoring
Validation study
heart rate variability (HRV)
url http://journal.frontiersin.org/Journal/10.3389/fphys.2016.00391/full
work_keys_str_mv AT abimbolaaakintola comparativeanalysisoftheequivitaleq02lifemonitorwithholterambulatoryecgdeviceforcontinuousmeasurementofecgheartrateandheartratevariabilityavalidationstudyforprecisionandaccuracy
AT veravandepol comparativeanalysisoftheequivitaleq02lifemonitorwithholterambulatoryecgdeviceforcontinuousmeasurementofecgheartrateandheartratevariabilityavalidationstudyforprecisionandaccuracy
AT danielbimmel comparativeanalysisoftheequivitaleq02lifemonitorwithholterambulatoryecgdeviceforcontinuousmeasurementofecgheartrateandheartratevariabilityavalidationstudyforprecisionandaccuracy
AT ariecmaan comparativeanalysisoftheequivitaleq02lifemonitorwithholterambulatoryecgdeviceforcontinuousmeasurementofecgheartrateandheartratevariabilityavalidationstudyforprecisionandaccuracy
AT dianavanheemst comparativeanalysisoftheequivitaleq02lifemonitorwithholterambulatoryecgdeviceforcontinuousmeasurementofecgheartrateandheartratevariabilityavalidationstudyforprecisionandaccuracy
_version_ 1725578270150230016