Accreditation of the analytical method used for nitrate determination in vegetables
The standard method of EN 12014-7 was used for the determination of nitrate content in vegetables in the Central Laboratory of the Agricultural Institute of Slovenia. Trueness of the method was verified by the analysis of samples in the interlaboratory proficiency testing scheme Bipea (Bure...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Belgrade, University of Novi Sad
2015-01-01
|
Series: | Archives of Biological Sciences |
Subjects: | |
Online Access: | http://www.doiserbia.nb.rs/img/doi/0354-4664/2015/0354-46641400046K.pdf |
id |
doaj-c466b59f76264cab9447698f6ae72167 |
---|---|
record_format |
Article |
spelling |
doaj-c466b59f76264cab9447698f6ae721672020-11-24T22:44:47ZengUniversity of Belgrade, University of Novi SadArchives of Biological Sciences0354-46641821-43392015-01-0167129530210.2298/ABS140428046K0354-46641400046KAccreditation of the analytical method used for nitrate determination in vegetablesKmecl Veronika0Žnidarčič Dragan1Agricultural Institute of Slovenia, Ljubljana, SloveniaUniversity of Ljubljana, Biotechnical Faculty, Department of Agronomy, Ljubljana, SloveniaThe standard method of EN 12014-7 was used for the determination of nitrate content in vegetables in the Central Laboratory of the Agricultural Institute of Slovenia. Trueness of the method was verified by the analysis of samples in the interlaboratory proficiency testing scheme Bipea (Bureau Interprofessionnel d'Etudes Analytiques). Linearity was confirmed by multiple linear regression; the correlation coefficient (R2) was 0.9993. The limit of detection (LOD) was calculated as 0.8 mg NO3-/kg and limit of quantification (LOQ) 3.0 mg NO3-/kg. Relative standard deviation (RSD) of repeatability was 4.6% and RSD of reproducibility 8.9%. The relative uncertainty of repeatability and reproducibility were 10.5% and 20.2%, respectively. The method has been accredited by the French Accreditation Committee COFRAC in 2007 and by the national Slovene Accreditation in 2012.http://www.doiserbia.nb.rs/img/doi/0354-4664/2015/0354-46641400046K.pdfnitratesvalidationaccreditationcontinuous flow method |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Kmecl Veronika Žnidarčič Dragan |
spellingShingle |
Kmecl Veronika Žnidarčič Dragan Accreditation of the analytical method used for nitrate determination in vegetables Archives of Biological Sciences nitrates validation accreditation continuous flow method |
author_facet |
Kmecl Veronika Žnidarčič Dragan |
author_sort |
Kmecl Veronika |
title |
Accreditation of the analytical method used for nitrate determination in vegetables |
title_short |
Accreditation of the analytical method used for nitrate determination in vegetables |
title_full |
Accreditation of the analytical method used for nitrate determination in vegetables |
title_fullStr |
Accreditation of the analytical method used for nitrate determination in vegetables |
title_full_unstemmed |
Accreditation of the analytical method used for nitrate determination in vegetables |
title_sort |
accreditation of the analytical method used for nitrate determination in vegetables |
publisher |
University of Belgrade, University of Novi Sad |
series |
Archives of Biological Sciences |
issn |
0354-4664 1821-4339 |
publishDate |
2015-01-01 |
description |
The standard method of EN 12014-7 was used for the determination of nitrate
content in vegetables in the Central Laboratory of the Agricultural
Institute of Slovenia. Trueness of the method was verified by the analysis
of samples in the interlaboratory proficiency testing scheme Bipea (Bureau
Interprofessionnel d'Etudes Analytiques). Linearity was confirmed by
multiple linear regression; the correlation coefficient (R2) was 0.9993. The
limit of detection (LOD) was calculated as 0.8 mg NO3-/kg and limit of
quantification (LOQ) 3.0 mg NO3-/kg. Relative standard deviation (RSD) of
repeatability was 4.6% and RSD of reproducibility 8.9%. The relative
uncertainty of repeatability and reproducibility were 10.5% and 20.2%,
respectively. The method has been accredited by the French Accreditation
Committee COFRAC in 2007 and by the national Slovene Accreditation in 2012. |