Feasibility study of conventional, DVSP, and THD-based heat supply systems

Thermohydraulic dispatcher (THD) can be widely used in district heating systems. Heat source is one of the possible places of its application. In this case, it is possible to achieve hydrodynamic separation of heat source and heat supply network. This paper deals with comparison of three types of he...

Full description

Bibliographic Details
Main Authors: Romanov D. O., Yavorovsky Y. V.
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/50/e3sconf_ses18_04007.pdf
id doaj-c43d4b3b9e3449139f2bfe0942655ade
record_format Article
spelling doaj-c43d4b3b9e3449139f2bfe0942655ade2021-02-02T04:56:01ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011240400710.1051/e3sconf/201912404007e3sconf_ses18_04007Feasibility study of conventional, DVSP, and THD-based heat supply systemsRomanov D. O.0Yavorovsky Y. V.1National Research University “Moscow Power Engineering Institute”National Research University “Moscow Power Engineering Institute”Thermohydraulic dispatcher (THD) can be widely used in district heating systems. Heat source is one of the possible places of its application. In this case, it is possible to achieve hydrodynamic separation of heat source and heat supply network. This paper deals with comparison of three types of heat substation connection to heat source: conventional system, DVSP system, THD-based system. The latter two have variable speed pumps instead of throttling valves. Based on electricity consumption and investment costs calculations, total discounted costs of three systems were estimated. In result, DVSP system is more beneficial, while conventional system and THD-based system have high operational and investment costs accordingly.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/50/e3sconf_ses18_04007.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Romanov D. O.
Yavorovsky Y. V.
spellingShingle Romanov D. O.
Yavorovsky Y. V.
Feasibility study of conventional, DVSP, and THD-based heat supply systems
E3S Web of Conferences
author_facet Romanov D. O.
Yavorovsky Y. V.
author_sort Romanov D. O.
title Feasibility study of conventional, DVSP, and THD-based heat supply systems
title_short Feasibility study of conventional, DVSP, and THD-based heat supply systems
title_full Feasibility study of conventional, DVSP, and THD-based heat supply systems
title_fullStr Feasibility study of conventional, DVSP, and THD-based heat supply systems
title_full_unstemmed Feasibility study of conventional, DVSP, and THD-based heat supply systems
title_sort feasibility study of conventional, dvsp, and thd-based heat supply systems
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2019-01-01
description Thermohydraulic dispatcher (THD) can be widely used in district heating systems. Heat source is one of the possible places of its application. In this case, it is possible to achieve hydrodynamic separation of heat source and heat supply network. This paper deals with comparison of three types of heat substation connection to heat source: conventional system, DVSP system, THD-based system. The latter two have variable speed pumps instead of throttling valves. Based on electricity consumption and investment costs calculations, total discounted costs of three systems were estimated. In result, DVSP system is more beneficial, while conventional system and THD-based system have high operational and investment costs accordingly.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/50/e3sconf_ses18_04007.pdf
work_keys_str_mv AT romanovdo feasibilitystudyofconventionaldvspandthdbasedheatsupplysystems