Feasibility study of conventional, DVSP, and THD-based heat supply systems
Thermohydraulic dispatcher (THD) can be widely used in district heating systems. Heat source is one of the possible places of its application. In this case, it is possible to achieve hydrodynamic separation of heat source and heat supply network. This paper deals with comparison of three types of he...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2019-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/50/e3sconf_ses18_04007.pdf |
id |
doaj-c43d4b3b9e3449139f2bfe0942655ade |
---|---|
record_format |
Article |
spelling |
doaj-c43d4b3b9e3449139f2bfe0942655ade2021-02-02T04:56:01ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011240400710.1051/e3sconf/201912404007e3sconf_ses18_04007Feasibility study of conventional, DVSP, and THD-based heat supply systemsRomanov D. O.0Yavorovsky Y. V.1National Research University “Moscow Power Engineering Institute”National Research University “Moscow Power Engineering Institute”Thermohydraulic dispatcher (THD) can be widely used in district heating systems. Heat source is one of the possible places of its application. In this case, it is possible to achieve hydrodynamic separation of heat source and heat supply network. This paper deals with comparison of three types of heat substation connection to heat source: conventional system, DVSP system, THD-based system. The latter two have variable speed pumps instead of throttling valves. Based on electricity consumption and investment costs calculations, total discounted costs of three systems were estimated. In result, DVSP system is more beneficial, while conventional system and THD-based system have high operational and investment costs accordingly.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/50/e3sconf_ses18_04007.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Romanov D. O. Yavorovsky Y. V. |
spellingShingle |
Romanov D. O. Yavorovsky Y. V. Feasibility study of conventional, DVSP, and THD-based heat supply systems E3S Web of Conferences |
author_facet |
Romanov D. O. Yavorovsky Y. V. |
author_sort |
Romanov D. O. |
title |
Feasibility study of conventional, DVSP, and THD-based heat supply systems |
title_short |
Feasibility study of conventional, DVSP, and THD-based heat supply systems |
title_full |
Feasibility study of conventional, DVSP, and THD-based heat supply systems |
title_fullStr |
Feasibility study of conventional, DVSP, and THD-based heat supply systems |
title_full_unstemmed |
Feasibility study of conventional, DVSP, and THD-based heat supply systems |
title_sort |
feasibility study of conventional, dvsp, and thd-based heat supply systems |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2019-01-01 |
description |
Thermohydraulic dispatcher (THD) can be widely used in district heating systems. Heat source is one of the possible places of its application. In this case, it is possible to achieve hydrodynamic separation of heat source and heat supply network. This paper deals with comparison of three types of heat substation connection to heat source: conventional system, DVSP system, THD-based system. The latter two have variable speed pumps instead of throttling valves. Based on electricity consumption and investment costs calculations, total discounted costs of three systems were estimated. In result, DVSP system is more beneficial, while conventional system and THD-based system have high operational and investment costs accordingly. |
url |
https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/50/e3sconf_ses18_04007.pdf |
work_keys_str_mv |
AT romanovdo feasibilitystudyofconventionaldvspandthdbasedheatsupplysystems AT yavorovskyyv feasibilitystudyofconventionaldvspandthdbasedheatsupplysystems |
_version_ |
1724304683782111232 |