Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm
This study investigates the effect of a novel flow remodeling stent graft (FRSG) on the hemodynamic characteristics in highly angulated abdominal aortic aneurysm based on computational fluid dynamics (CFD) approach. An idealized aortic aneurysm with varying aortic neck angulations was constructed an...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2016-01-01
|
Series: | Computational and Mathematical Methods in Medicine |
Online Access: | http://dx.doi.org/10.1155/2016/3830123 |
id |
doaj-c32d528c2f8f47d0a026d7c90308cc6d |
---|---|
record_format |
Article |
spelling |
doaj-c32d528c2f8f47d0a026d7c90308cc6d2020-11-25T01:05:35ZengHindawi LimitedComputational and Mathematical Methods in Medicine1748-670X1748-67182016-01-01201610.1155/2016/38301233830123Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic AneurysmSiang Lin Yeow0Hwa Liang Leo1Department of Biomedical Engineering, Faculty of Engineering, National University of Singapore, 117575, SingaporeDepartment of Biomedical Engineering, Faculty of Engineering, National University of Singapore, 117575, SingaporeThis study investigates the effect of a novel flow remodeling stent graft (FRSG) on the hemodynamic characteristics in highly angulated abdominal aortic aneurysm based on computational fluid dynamics (CFD) approach. An idealized aortic aneurysm with varying aortic neck angulations was constructed and CFD simulations were performed on nonstented models and stented models with FRSG. The influence of FRSG intervention on the hemodynamic performance is analyzed and compared in terms of flow patterns, wall shear stress (WSS), and pressure distribution in the aneurysm. The findings showed that aortic neck angulations significantly influence the velocity flow field in nonstented models, with larger angulations shifting the mainstream blood flow towards the center of the aorta. By introducing FRSG treatment into the aneurysm, erratic flow recirculation pattern in the aneurysm sac diminishes while the average velocity magnitude in the aneurysm sac was reduced in the range of 39% to 53%. FRSG intervention protects the aneurysm against the impacts of high velocity concentrated flow and decreases wall shear stress by more than 50%. The simulation results highlighted that FRSG may effectively treat aneurysm with high aortic neck angulations via the mechanism of promoting thrombus formation and subsequently led to the resorption of the aneurysm.http://dx.doi.org/10.1155/2016/3830123 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Siang Lin Yeow Hwa Liang Leo |
spellingShingle |
Siang Lin Yeow Hwa Liang Leo Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm Computational and Mathematical Methods in Medicine |
author_facet |
Siang Lin Yeow Hwa Liang Leo |
author_sort |
Siang Lin Yeow |
title |
Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm |
title_short |
Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm |
title_full |
Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm |
title_fullStr |
Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm |
title_full_unstemmed |
Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm |
title_sort |
hemodynamic study of flow remodeling stent graft for the treatment of highly angulated abdominal aortic aneurysm |
publisher |
Hindawi Limited |
series |
Computational and Mathematical Methods in Medicine |
issn |
1748-670X 1748-6718 |
publishDate |
2016-01-01 |
description |
This study investigates the effect of a novel flow remodeling stent graft (FRSG) on the hemodynamic characteristics in highly angulated abdominal aortic aneurysm based on computational fluid dynamics (CFD) approach. An idealized aortic aneurysm with varying aortic neck angulations was constructed and CFD simulations were performed on nonstented models and stented models with FRSG. The influence of FRSG intervention on the hemodynamic performance is analyzed and compared in terms of flow patterns, wall shear stress (WSS), and pressure distribution in the aneurysm. The findings showed that aortic neck angulations significantly influence the velocity flow field in nonstented models, with larger angulations shifting the mainstream blood flow towards the center of the aorta. By introducing FRSG treatment into the aneurysm, erratic flow recirculation pattern in the aneurysm sac diminishes while the average velocity magnitude in the aneurysm sac was reduced in the range of 39% to 53%. FRSG intervention protects the aneurysm against the impacts of high velocity concentrated flow and decreases wall shear stress by more than 50%. The simulation results highlighted that FRSG may effectively treat aneurysm with high aortic neck angulations via the mechanism of promoting thrombus formation and subsequently led to the resorption of the aneurysm. |
url |
http://dx.doi.org/10.1155/2016/3830123 |
work_keys_str_mv |
AT sianglinyeow hemodynamicstudyofflowremodelingstentgraftforthetreatmentofhighlyangulatedabdominalaorticaneurysm AT hwaliangleo hemodynamicstudyofflowremodelingstentgraftforthetreatmentofhighlyangulatedabdominalaorticaneurysm |
_version_ |
1725193688622039040 |