Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm

This study investigates the effect of a novel flow remodeling stent graft (FRSG) on the hemodynamic characteristics in highly angulated abdominal aortic aneurysm based on computational fluid dynamics (CFD) approach. An idealized aortic aneurysm with varying aortic neck angulations was constructed an...

Full description

Bibliographic Details
Main Authors: Siang Lin Yeow, Hwa Liang Leo
Format: Article
Language:English
Published: Hindawi Limited 2016-01-01
Series:Computational and Mathematical Methods in Medicine
Online Access:http://dx.doi.org/10.1155/2016/3830123
id doaj-c32d528c2f8f47d0a026d7c90308cc6d
record_format Article
spelling doaj-c32d528c2f8f47d0a026d7c90308cc6d2020-11-25T01:05:35ZengHindawi LimitedComputational and Mathematical Methods in Medicine1748-670X1748-67182016-01-01201610.1155/2016/38301233830123Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic AneurysmSiang Lin Yeow0Hwa Liang Leo1Department of Biomedical Engineering, Faculty of Engineering, National University of Singapore, 117575, SingaporeDepartment of Biomedical Engineering, Faculty of Engineering, National University of Singapore, 117575, SingaporeThis study investigates the effect of a novel flow remodeling stent graft (FRSG) on the hemodynamic characteristics in highly angulated abdominal aortic aneurysm based on computational fluid dynamics (CFD) approach. An idealized aortic aneurysm with varying aortic neck angulations was constructed and CFD simulations were performed on nonstented models and stented models with FRSG. The influence of FRSG intervention on the hemodynamic performance is analyzed and compared in terms of flow patterns, wall shear stress (WSS), and pressure distribution in the aneurysm. The findings showed that aortic neck angulations significantly influence the velocity flow field in nonstented models, with larger angulations shifting the mainstream blood flow towards the center of the aorta. By introducing FRSG treatment into the aneurysm, erratic flow recirculation pattern in the aneurysm sac diminishes while the average velocity magnitude in the aneurysm sac was reduced in the range of 39% to 53%. FRSG intervention protects the aneurysm against the impacts of high velocity concentrated flow and decreases wall shear stress by more than 50%. The simulation results highlighted that FRSG may effectively treat aneurysm with high aortic neck angulations via the mechanism of promoting thrombus formation and subsequently led to the resorption of the aneurysm.http://dx.doi.org/10.1155/2016/3830123
collection DOAJ
language English
format Article
sources DOAJ
author Siang Lin Yeow
Hwa Liang Leo
spellingShingle Siang Lin Yeow
Hwa Liang Leo
Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm
Computational and Mathematical Methods in Medicine
author_facet Siang Lin Yeow
Hwa Liang Leo
author_sort Siang Lin Yeow
title Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm
title_short Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm
title_full Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm
title_fullStr Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm
title_full_unstemmed Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm
title_sort hemodynamic study of flow remodeling stent graft for the treatment of highly angulated abdominal aortic aneurysm
publisher Hindawi Limited
series Computational and Mathematical Methods in Medicine
issn 1748-670X
1748-6718
publishDate 2016-01-01
description This study investigates the effect of a novel flow remodeling stent graft (FRSG) on the hemodynamic characteristics in highly angulated abdominal aortic aneurysm based on computational fluid dynamics (CFD) approach. An idealized aortic aneurysm with varying aortic neck angulations was constructed and CFD simulations were performed on nonstented models and stented models with FRSG. The influence of FRSG intervention on the hemodynamic performance is analyzed and compared in terms of flow patterns, wall shear stress (WSS), and pressure distribution in the aneurysm. The findings showed that aortic neck angulations significantly influence the velocity flow field in nonstented models, with larger angulations shifting the mainstream blood flow towards the center of the aorta. By introducing FRSG treatment into the aneurysm, erratic flow recirculation pattern in the aneurysm sac diminishes while the average velocity magnitude in the aneurysm sac was reduced in the range of 39% to 53%. FRSG intervention protects the aneurysm against the impacts of high velocity concentrated flow and decreases wall shear stress by more than 50%. The simulation results highlighted that FRSG may effectively treat aneurysm with high aortic neck angulations via the mechanism of promoting thrombus formation and subsequently led to the resorption of the aneurysm.
url http://dx.doi.org/10.1155/2016/3830123
work_keys_str_mv AT sianglinyeow hemodynamicstudyofflowremodelingstentgraftforthetreatmentofhighlyangulatedabdominalaorticaneurysm
AT hwaliangleo hemodynamicstudyofflowremodelingstentgraftforthetreatmentofhighlyangulatedabdominalaorticaneurysm
_version_ 1725193688622039040