Reduction of Human Interaction with Wireless Power Transfer System Using Shielded Loop Coil

The impedance variation of wireless power transfer (WPT) coils owing to the presence of the human body may result in mismatches, resulting in a decrease of the transmission efficiency. In addition, one of the decisive factors of the permissible transfer power in WPT systems is a compliance assessmen...

Full description

Bibliographic Details
Main Authors: Akihiko Kumazawa, Yinliang Diao, Akimasa Hirata, Hiroshi Hirayama
Format: Article
Language:English
Published: MDPI AG 2020-06-01
Series:Electronics
Subjects:
SAR
Online Access:https://www.mdpi.com/2079-9292/9/6/953
Description
Summary:The impedance variation of wireless power transfer (WPT) coils owing to the presence of the human body may result in mismatches, resulting in a decrease of the transmission efficiency. In addition, one of the decisive factors of the permissible transfer power in WPT systems is a compliance assessment with the guidelines/standards for human protection from electromagnetic fields. In our previous study, we reported that a shielded loop coil can potentially reduce human interaction with WPT coils. In this study, first, the rationale for this reduction is investigated with equivalent circuit models for a WPT system using a shielded loop coil operated in close proximity to the human body. We then conducted an equivalent circuit analysis considering the capacitance between the inner and outer conductors of the shielded loop coil, suggesting the stability of the impedance matching. From computational results, the mitigation capability of the shielded loop coil on impedance matching and transmission efficiency owing to the presence of the human body was verified for 6.78 MHz wireless power transfer. Additionally, the reduction of the specific absorption rate (SAR) with coils comprised of the shielded loop structure was confirmed in the presence of anatomically realistic human body models. The maximum transferable power was increased from 1.5 kW to 2.1 kW for the restrictions of the local SAR limit prescribed in the international safety guidelines/standard.
ISSN:2079-9292