Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter

The tissue equivalent proportional counter (TEPC) is often used in the measurement of ionizing radiation. However, there are many factors that can cause the micro-dose spectrum’s distortion and affect the accuracy of the measurement. In the TEPC design process, several factors can be analyzed throug...

Full description

Bibliographic Details
Main Authors: Min Zhu, Biao Li, Fei Wu, Shengao Wang, Shaohua Sun, Huang Huang, Gui Huang, Zijian Xu
Format: Article
Language:English
Published: AIP Publishing LLC 2021-03-01
Series:AIP Advances
Online Access:http://dx.doi.org/10.1063/5.0042344
id doaj-c1e2bb5eeecc467cb3342e8fe437621d
record_format Article
spelling doaj-c1e2bb5eeecc467cb3342e8fe437621d2021-04-02T15:45:27ZengAIP Publishing LLCAIP Advances2158-32262021-03-01113035118035118-510.1063/5.0042344Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counterMin Zhu0Biao Li1Fei Wu2Shengao Wang3Shaohua Sun4Huang Huang5Gui Huang6Zijian Xu7College of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaThe tissue equivalent proportional counter (TEPC) is often used in the measurement of ionizing radiation. However, there are many factors that can cause the micro-dose spectrum’s distortion and affect the accuracy of the measurement. In the TEPC design process, several factors can be analyzed through simulation methods. The simulation capabilities of the TEPC physical process are established and verified in this paper. The wall material, tissue equivalent gas, and electrode are selected as the main objects, and the corresponding design choices are given. The wall material has a great impact on the spectrum, and y¯F and y¯D show that A-150 plastic is closer to the human tissue in the TEPC physical process simulation. Both the two tissue equivalent gases have good simulation accuracy. After further analysis, propane-based equivalent gas is the better choice. Among the three electrode sizes, the size of 0.006 35 cm is the most suitable one for TEPC. The analysis results and analysis methods can provide references for the important elements design of TEPC.http://dx.doi.org/10.1063/5.0042344
collection DOAJ
language English
format Article
sources DOAJ
author Min Zhu
Biao Li
Fei Wu
Shengao Wang
Shaohua Sun
Huang Huang
Gui Huang
Zijian Xu
spellingShingle Min Zhu
Biao Li
Fei Wu
Shengao Wang
Shaohua Sun
Huang Huang
Gui Huang
Zijian Xu
Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
AIP Advances
author_facet Min Zhu
Biao Li
Fei Wu
Shengao Wang
Shaohua Sun
Huang Huang
Gui Huang
Zijian Xu
author_sort Min Zhu
title Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
title_short Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
title_full Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
title_fullStr Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
title_full_unstemmed Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
title_sort analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
publisher AIP Publishing LLC
series AIP Advances
issn 2158-3226
publishDate 2021-03-01
description The tissue equivalent proportional counter (TEPC) is often used in the measurement of ionizing radiation. However, there are many factors that can cause the micro-dose spectrum’s distortion and affect the accuracy of the measurement. In the TEPC design process, several factors can be analyzed through simulation methods. The simulation capabilities of the TEPC physical process are established and verified in this paper. The wall material, tissue equivalent gas, and electrode are selected as the main objects, and the corresponding design choices are given. The wall material has a great impact on the spectrum, and y¯F and y¯D show that A-150 plastic is closer to the human tissue in the TEPC physical process simulation. Both the two tissue equivalent gases have good simulation accuracy. After further analysis, propane-based equivalent gas is the better choice. Among the three electrode sizes, the size of 0.006 35 cm is the most suitable one for TEPC. The analysis results and analysis methods can provide references for the important elements design of TEPC.
url http://dx.doi.org/10.1063/5.0042344
work_keys_str_mv AT minzhu analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter
AT biaoli analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter
AT feiwu analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter
AT shengaowang analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter
AT shaohuasun analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter
AT huanghuang analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter
AT guihuang analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter
AT zijianxu analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter
_version_ 1721559206013698048