Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter
The tissue equivalent proportional counter (TEPC) is often used in the measurement of ionizing radiation. However, there are many factors that can cause the micro-dose spectrum’s distortion and affect the accuracy of the measurement. In the TEPC design process, several factors can be analyzed throug...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
AIP Publishing LLC
2021-03-01
|
Series: | AIP Advances |
Online Access: | http://dx.doi.org/10.1063/5.0042344 |
id |
doaj-c1e2bb5eeecc467cb3342e8fe437621d |
---|---|
record_format |
Article |
spelling |
doaj-c1e2bb5eeecc467cb3342e8fe437621d2021-04-02T15:45:27ZengAIP Publishing LLCAIP Advances2158-32262021-03-01113035118035118-510.1063/5.0042344Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counterMin Zhu0Biao Li1Fei Wu2Shengao Wang3Shaohua Sun4Huang Huang5Gui Huang6Zijian Xu7College of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaCollege of Nuclear Science and Technology, Naval University of Engineering, Wuhan City 430033, ChinaThe tissue equivalent proportional counter (TEPC) is often used in the measurement of ionizing radiation. However, there are many factors that can cause the micro-dose spectrum’s distortion and affect the accuracy of the measurement. In the TEPC design process, several factors can be analyzed through simulation methods. The simulation capabilities of the TEPC physical process are established and verified in this paper. The wall material, tissue equivalent gas, and electrode are selected as the main objects, and the corresponding design choices are given. The wall material has a great impact on the spectrum, and y¯F and y¯D show that A-150 plastic is closer to the human tissue in the TEPC physical process simulation. Both the two tissue equivalent gases have good simulation accuracy. After further analysis, propane-based equivalent gas is the better choice. Among the three electrode sizes, the size of 0.006 35 cm is the most suitable one for TEPC. The analysis results and analysis methods can provide references for the important elements design of TEPC.http://dx.doi.org/10.1063/5.0042344 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Min Zhu Biao Li Fei Wu Shengao Wang Shaohua Sun Huang Huang Gui Huang Zijian Xu |
spellingShingle |
Min Zhu Biao Li Fei Wu Shengao Wang Shaohua Sun Huang Huang Gui Huang Zijian Xu Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter AIP Advances |
author_facet |
Min Zhu Biao Li Fei Wu Shengao Wang Shaohua Sun Huang Huang Gui Huang Zijian Xu |
author_sort |
Min Zhu |
title |
Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter |
title_short |
Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter |
title_full |
Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter |
title_fullStr |
Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter |
title_full_unstemmed |
Analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter |
title_sort |
analysis of micro-dose spectrum influencing factors based on tissue equivalent proportional counter |
publisher |
AIP Publishing LLC |
series |
AIP Advances |
issn |
2158-3226 |
publishDate |
2021-03-01 |
description |
The tissue equivalent proportional counter (TEPC) is often used in the measurement of ionizing radiation. However, there are many factors that can cause the micro-dose spectrum’s distortion and affect the accuracy of the measurement. In the TEPC design process, several factors can be analyzed through simulation methods. The simulation capabilities of the TEPC physical process are established and verified in this paper. The wall material, tissue equivalent gas, and electrode are selected as the main objects, and the corresponding design choices are given. The wall material has a great impact on the spectrum, and y¯F and y¯D show that A-150 plastic is closer to the human tissue in the TEPC physical process simulation. Both the two tissue equivalent gases have good simulation accuracy. After further analysis, propane-based equivalent gas is the better choice. Among the three electrode sizes, the size of 0.006 35 cm is the most suitable one for TEPC. The analysis results and analysis methods can provide references for the important elements design of TEPC. |
url |
http://dx.doi.org/10.1063/5.0042344 |
work_keys_str_mv |
AT minzhu analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter AT biaoli analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter AT feiwu analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter AT shengaowang analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter AT shaohuasun analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter AT huanghuang analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter AT guihuang analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter AT zijianxu analysisofmicrodosespectruminfluencingfactorsbasedontissueequivalentproportionalcounter |
_version_ |
1721559206013698048 |