Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties
Background: The three-way indwelling urinary catheter (IUC) is used for continuous bladder irrigation and is considered the cornerstone for clinical treatment of patients with macroscopic hematuria. Although there seems to be a logical relationship between catheter size and efficacy of irrigation an...
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2020-01-01
|
Series: | Therapeutic Advances in Urology |
Online Access: | https://doi.org/10.1177/1756287219889496 |
id |
doaj-c1e207fc3d6540b7b3a94c6c2f4046ef |
---|---|
record_format |
Article |
spelling |
doaj-c1e207fc3d6540b7b3a94c6c2f4046ef2020-11-25T03:42:15ZengSAGE PublishingTherapeutic Advances in Urology1756-28802020-01-011210.1177/1756287219889496Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage propertiesArie CarneiroMarcelo Langer WroclawskiGuilherme Andrade PeixotoJonathan Doyun ChaNatasha Kouvaleski Saviano MoranFelipe Ko ChenHenrique Nelson SatkunasJosé Roberto Augusto CamposAlides Maria Mendes Rasabone GarciaManoj MongaGustavo Caserta LemosBackground: The three-way indwelling urinary catheter (IUC) is used for continuous bladder irrigation and is considered the cornerstone for clinical treatment of patients with macroscopic hematuria. Although there seems to be a logical relationship between catheter size and efficacy of irrigation and drainage, we often observe relevant variations in these parameters between different brands of catheters available on the market. The aim of this study was to compare the mechanical properties of different models of latex and silicone three-way catheters in an in vitro setting that resembles clinical use. Methods: Three different three-way catheters were evaluated: Gold Silicone-Coated Rusch ® (Model A), 100% Silicone Rusch ® (Model B) and X-Flow Coloplast ® (Model C). Irrigation channel, drainage channel, and overall cross-sectional areas were all digitally measured. Irrigation and drainage channel flow rates were measured and correlated with their corresponding catheter cross-sectional area values. Results: Different catheter models of the same caliber have different internal irrigation port diameters, internal drainage port diameters and internal cuff port diameters. The Model C IUC internal irrigation port diameter is significantly larger than models A and B. When flows were evaluated, we found that in the same model, the increase in caliber of the IUC was related to an increased drainage flow, but not to an increased irrigation flow. Conclusion: Precise measurements of the internal architecture of the three-way catheter, rather than relying on the caliber itself, could assist surgeons in choosing the best product for each specific patient, while minimizing complications.https://doi.org/10.1177/1756287219889496 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Arie Carneiro Marcelo Langer Wroclawski Guilherme Andrade Peixoto Jonathan Doyun Cha Natasha Kouvaleski Saviano Moran Felipe Ko Chen Henrique Nelson Satkunas José Roberto Augusto Campos Alides Maria Mendes Rasabone Garcia Manoj Monga Gustavo Caserta Lemos |
spellingShingle |
Arie Carneiro Marcelo Langer Wroclawski Guilherme Andrade Peixoto Jonathan Doyun Cha Natasha Kouvaleski Saviano Moran Felipe Ko Chen Henrique Nelson Satkunas José Roberto Augusto Campos Alides Maria Mendes Rasabone Garcia Manoj Monga Gustavo Caserta Lemos Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties Therapeutic Advances in Urology |
author_facet |
Arie Carneiro Marcelo Langer Wroclawski Guilherme Andrade Peixoto Jonathan Doyun Cha Natasha Kouvaleski Saviano Moran Felipe Ko Chen Henrique Nelson Satkunas José Roberto Augusto Campos Alides Maria Mendes Rasabone Garcia Manoj Monga Gustavo Caserta Lemos |
author_sort |
Arie Carneiro |
title |
Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties |
title_short |
Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties |
title_full |
Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties |
title_fullStr |
Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties |
title_full_unstemmed |
Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties |
title_sort |
same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties |
publisher |
SAGE Publishing |
series |
Therapeutic Advances in Urology |
issn |
1756-2880 |
publishDate |
2020-01-01 |
description |
Background: The three-way indwelling urinary catheter (IUC) is used for continuous bladder irrigation and is considered the cornerstone for clinical treatment of patients with macroscopic hematuria. Although there seems to be a logical relationship between catheter size and efficacy of irrigation and drainage, we often observe relevant variations in these parameters between different brands of catheters available on the market. The aim of this study was to compare the mechanical properties of different models of latex and silicone three-way catheters in an in vitro setting that resembles clinical use. Methods: Three different three-way catheters were evaluated: Gold Silicone-Coated Rusch ® (Model A), 100% Silicone Rusch ® (Model B) and X-Flow Coloplast ® (Model C). Irrigation channel, drainage channel, and overall cross-sectional areas were all digitally measured. Irrigation and drainage channel flow rates were measured and correlated with their corresponding catheter cross-sectional area values. Results: Different catheter models of the same caliber have different internal irrigation port diameters, internal drainage port diameters and internal cuff port diameters. The Model C IUC internal irrigation port diameter is significantly larger than models A and B. When flows were evaluated, we found that in the same model, the increase in caliber of the IUC was related to an increased drainage flow, but not to an increased irrigation flow. Conclusion: Precise measurements of the internal architecture of the three-way catheter, rather than relying on the caliber itself, could assist surgeons in choosing the best product for each specific patient, while minimizing complications. |
url |
https://doi.org/10.1177/1756287219889496 |
work_keys_str_mv |
AT ariecarneiro samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT marcelolangerwroclawski samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT guilhermeandradepeixoto samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT jonathandoyuncha samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT natashakouvaleskisavianomoran samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT felipekochen samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT henriquenelsonsatkunas samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT joserobertoaugustocampos samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT alidesmariamendesrasabonegarcia samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT manojmonga samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties AT gustavocasertalemos samesizedthreewayindwellingurinarycathetersfromvariousmanufacturerspresentdifferentirrigationanddrainageproperties |
_version_ |
1724526253600407552 |