THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE

A potentiometric selective sensor based on trinuclear chromium(III) complex as a novel ionophore for the thiocyanateselective electrode is reported. The sensor displays a near Nernstian slope of 57 ± 2 mV per decade, over a wide pH range 3 - 11. The working concentration range of the electrode is 1...

Full description

Bibliographic Details
Main Authors: Mihail Revenco, Mariana Martin, Waell Abu Dayyih
Format: Article
Language:English
Published: Academy of Sciences of Moldova, Institute of Chemistry 2010-06-01
Series:Chemistry Journal of Moldova: General, Industrial and Ecological Chemistry
Subjects:
Online Access:http://www.cjm.asm.md/sites/default/files/article_files/73-77%20Revenco.pdf
id doaj-c17689c0ea8748399f96862103b19898
record_format Article
spelling doaj-c17689c0ea8748399f96862103b198982021-07-02T08:10:20ZengAcademy of Sciences of Moldova, Institute of ChemistryChemistry Journal of Moldova: General, Industrial and Ecological Chemistry1857-17272345-16882010-06-01517377THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODEMihail Revenco0Mariana Martin1Waell Abu Dayyih2State University of MoldovaState University of MoldovaPetra University, Faculty of Pharmacy and Medical Sciences, Amman, Jordan A potentiometric selective sensor based on trinuclear chromium(III) complex as a novel ionophore for the thiocyanateselective electrode is reported. The sensor displays a near Nernstian slope of 57 ± 2 mV per decade, over a wide pH range 3 - 11. The working concentration range of the electrode is 1.10-5 – 1.10-1 mol/l with a detection limit of 5.10-6 mol/l. The sensor has a response time of 20 s and can be used for at least 6 months without any considerable fluctuation of the potential. The selectivity coefficients determined at using the fixed interference method indicate a good discriminating ability towards other anions. The prepared sensor was applied as an indicator electrode in the titration of thiocyanate with Ag+.http://www.cjm.asm.md/sites/default/files/article_files/73-77%20Revenco.pdfthiocyanatepotentiometric sensortitration
collection DOAJ
language English
format Article
sources DOAJ
author Mihail Revenco
Mariana Martin
Waell Abu Dayyih
spellingShingle Mihail Revenco
Mariana Martin
Waell Abu Dayyih
THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
Chemistry Journal of Moldova: General, Industrial and Ecological Chemistry
thiocyanate
potentiometric sensor
titration
author_facet Mihail Revenco
Mariana Martin
Waell Abu Dayyih
author_sort Mihail Revenco
title THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
title_short THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
title_full THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
title_fullStr THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
title_full_unstemmed THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
title_sort thiocyanate ion-selective pvc membrane electrode
publisher Academy of Sciences of Moldova, Institute of Chemistry
series Chemistry Journal of Moldova: General, Industrial and Ecological Chemistry
issn 1857-1727
2345-1688
publishDate 2010-06-01
description A potentiometric selective sensor based on trinuclear chromium(III) complex as a novel ionophore for the thiocyanateselective electrode is reported. The sensor displays a near Nernstian slope of 57 ± 2 mV per decade, over a wide pH range 3 - 11. The working concentration range of the electrode is 1.10-5 – 1.10-1 mol/l with a detection limit of 5.10-6 mol/l. The sensor has a response time of 20 s and can be used for at least 6 months without any considerable fluctuation of the potential. The selectivity coefficients determined at using the fixed interference method indicate a good discriminating ability towards other anions. The prepared sensor was applied as an indicator electrode in the titration of thiocyanate with Ag+.
topic thiocyanate
potentiometric sensor
titration
url http://www.cjm.asm.md/sites/default/files/article_files/73-77%20Revenco.pdf
work_keys_str_mv AT mihailrevenco thiocyanateionselectivepvcmembraneelectrode
AT marianamartin thiocyanateionselectivepvcmembraneelectrode
AT waellabudayyih thiocyanateionselectivepvcmembraneelectrode
_version_ 1721335037679370240