A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings
Background: The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan. Materials and methods: In the...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
College of Dentistry/ University of Baghdad
2015-12-01
|
Series: | Journal of Baghdad College of Dentistry |
Online Access: | https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/945 |
id |
doaj-c145a2102d8e4530830df9c7bbc9123e |
---|---|
record_format |
Article |
spelling |
doaj-c145a2102d8e4530830df9c7bbc9123e2021-09-02T21:58:17ZengCollege of Dentistry/ University of BaghdadJournal of Baghdad College of Dentistry2311-52702015-12-01274A Micro Computed Tomography Assessment of New Carrier-Based Root Canal FillingsRaghad A Al-HashimiBackground: The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan. Materials and methods: In the present study, eight straight single-rooted human permanent premolar teeth are selected and disinfected, then stored in distilled water. The teeth decoronated leaving a root length of 12mm each. The root canals instrumented by using crown down technique and the apical diameter of the root canal prepared to a size # 30/0.04 for achieving standardized measurements. A 5mL of 17% EDTA used to remove the smear layer followed by 5mL of 2.5% NaOCl and rinsing with normal saline. Then the shaped root canals were randomly subdivided into two groups of 4 teeth each according to the carrier-based obturation system use, GuttaCore or experimental HA/PE. Afterwards, the obturated roots stored at 37°C with 100% humidity for 72 hours to allow for complete setting of the sealer. Micro-CT was then scanned to quantify the voids within the root canal space. The data were statistically analyzed by one-way ANOVA and post hoc comparison tests (α=0.05). Results: The root canals obturated with both obturation systems, GuttaCore andexperimental HA/PE showed voids formation, particularly at the apical third of the root canal. GC obturation showed a lower percentage of voids volume (1.54%) than the experimental HA/PE obturation (2.3%). The void volume percentage in the GuttaCore system, however, was non-significantly different (P> 0.05) in comparison with the experimental PE/HA system. Conclusions: GuttaCore and experimental HA/PE obturators exhibited voids formation within the entire root canal space. The experimental HA/PE obturator is comparable to the GuttaCore obturator in terms of voids qualification https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/945 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Raghad A Al-Hashimi |
spellingShingle |
Raghad A Al-Hashimi A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings Journal of Baghdad College of Dentistry |
author_facet |
Raghad A Al-Hashimi |
author_sort |
Raghad A Al-Hashimi |
title |
A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings |
title_short |
A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings |
title_full |
A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings |
title_fullStr |
A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings |
title_full_unstemmed |
A Micro Computed Tomography Assessment of New Carrier-Based Root Canal Fillings |
title_sort |
micro computed tomography assessment of new carrier-based root canal fillings |
publisher |
College of Dentistry/ University of Baghdad |
series |
Journal of Baghdad College of Dentistry |
issn |
2311-5270 |
publishDate |
2015-12-01 |
description |
Background: The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan.
Materials and methods: In the present study, eight straight single-rooted human permanent premolar teeth are selected and disinfected, then stored in distilled water. The teeth decoronated leaving a root length of 12mm each. The root canals instrumented by using crown down technique and the apical diameter of the root canal prepared to a size # 30/0.04 for achieving standardized measurements. A 5mL of 17% EDTA used to remove the smear layer followed by 5mL of 2.5% NaOCl and rinsing with normal saline. Then the shaped root canals were randomly subdivided into two groups of 4 teeth each according to the carrier-based obturation system use, GuttaCore or experimental HA/PE. Afterwards, the obturated roots stored at 37°C with 100% humidity for 72 hours to allow for complete setting of the sealer. Micro-CT was then scanned to quantify the voids within the root canal space. The data were statistically analyzed by one-way ANOVA and post hoc comparison tests (α=0.05).
Results: The root canals obturated with both obturation systems, GuttaCore andexperimental HA/PE showed voids formation, particularly at the apical third of the root canal. GC obturation showed a lower percentage of voids volume (1.54%) than the experimental HA/PE obturation (2.3%). The void volume percentage in the GuttaCore system, however, was non-significantly different (P> 0.05) in comparison with the experimental PE/HA system.
Conclusions: GuttaCore and experimental HA/PE obturators exhibited voids formation within the entire root canal space. The experimental HA/PE obturator is comparable to the GuttaCore obturator in terms of voids qualification
|
url |
https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/945 |
work_keys_str_mv |
AT raghadaalhashimi amicrocomputedtomographyassessmentofnewcarrierbasedrootcanalfillings AT raghadaalhashimi microcomputedtomographyassessmentofnewcarrierbasedrootcanalfillings |
_version_ |
1717819045067096064 |