Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparison

<p>Abstract</p> <p>Background</p> <p>Biological brain tumor imaging using O-(2-[<sup>18</sup>F]fluoroethyl)-L-tyrosine (FET)-PET combined with inverse treatment planning for locally restricted dose escalation in patients with glioblastoma multiforme seems to...

Full description

Bibliographic Details
Main Authors: Stoffels Gabriele, Holy Richard, Pinkawa Michael, Piroth Marc D, Demirel Cengiz, Attieh Charbel, Kaiser Hans J, Langen Karl J, Eble Michael J
Format: Article
Language:English
Published: BMC 2009-11-01
Series:Radiation Oncology
Online Access:http://www.ro-journal.com/content/4/1/57
id doaj-bf58f328cd804cca9a4ae5762cca0b4b
record_format Article
spelling doaj-bf58f328cd804cca9a4ae5762cca0b4b2020-11-25T00:44:16ZengBMCRadiation Oncology1748-717X2009-11-01415710.1186/1748-717X-4-57Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparisonStoffels GabrieleHoly RichardPinkawa MichaelPiroth Marc DDemirel CengizAttieh CharbelKaiser Hans JLangen Karl JEble Michael J<p>Abstract</p> <p>Background</p> <p>Biological brain tumor imaging using O-(2-[<sup>18</sup>F]fluoroethyl)-L-tyrosine (FET)-PET combined with inverse treatment planning for locally restricted dose escalation in patients with glioblastoma multiforme seems to be a promising approach.</p> <p>The aim of this study was to compare inverse with forward treatment planning for an integrated boost dose application in patients suffering from a glioblastoma multiforme, while biological target volumes are based on FET-PET and MRI data sets.</p> <p>Methods</p> <p>In 16 glioblastoma patients an intensity-modulated radiotherapy technique comprising an integrated boost (IB-IMRT) and a 3-dimensional conventional radiotherapy (3D-CRT) technique were generated for dosimetric comparison. FET-PET, MRI and treatment planning CT (P-CT) were co-registrated. The integrated boost volume (PTV1) was auto-contoured using a cut-off tumor-to-brain ratio (TBR) of ≥ 1.6 from FET-PET. PTV2 delineation was MRI-based. The total dose was prescribed to 72 and 60 Gy for PTV1 and PTV2, using daily fractions of 2.4 and 2 Gy.</p> <p>Results</p> <p>After auto-contouring of PTV1 a marked target shape complexity had an impact on the dosimetric outcome. Patients with 3-4 PTV1 subvolumes vs. a single volume revealed a significant decrease in mean dose (67.7 vs. 70.6 Gy). From convex to complex shaped PTV1 mean doses decreased from 71.3 Gy to 67.7 Gy. The homogeneity and conformity for PTV1 and PTV2 was significantly improved with IB-IMRT. With the use of IB-IMRT the minimum dose within PTV1 (61.1 vs. 57.4 Gy) and PTV2 (51.4 vs. 40.9 Gy) increased significantly, and the mean EUD for PTV2 was improved (59.9 vs. 55.3 Gy, p < 0.01). The EUD for PTV1 was only slightly improved (68.3 vs. 67.3 Gy). The EUD for the brain was equal with both planning techniques.</p> <p>Conclusion</p> <p>In the presented planning study the integrated boost concept based on inversely planned IB-IMRT is feasible. The FET-PET-based automatically contoured PTV1 can lead to very complex geometric configurations, limiting the achievable mean dose in the boost volume. With IB-IMRT a better homogeneity and conformity, compared to 3D-CRT, could be achieved.</p> http://www.ro-journal.com/content/4/1/57
collection DOAJ
language English
format Article
sources DOAJ
author Stoffels Gabriele
Holy Richard
Pinkawa Michael
Piroth Marc D
Demirel Cengiz
Attieh Charbel
Kaiser Hans J
Langen Karl J
Eble Michael J
spellingShingle Stoffels Gabriele
Holy Richard
Pinkawa Michael
Piroth Marc D
Demirel Cengiz
Attieh Charbel
Kaiser Hans J
Langen Karl J
Eble Michael J
Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparison
Radiation Oncology
author_facet Stoffels Gabriele
Holy Richard
Pinkawa Michael
Piroth Marc D
Demirel Cengiz
Attieh Charbel
Kaiser Hans J
Langen Karl J
Eble Michael J
author_sort Stoffels Gabriele
title Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparison
title_short Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparison
title_full Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparison
title_fullStr Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparison
title_full_unstemmed Integrated-boost IMRT or 3-D-CRT using FET-PET based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparison
title_sort integrated-boost imrt or 3-d-crt using fet-pet based auto-contoured target volume delineation for glioblastoma multiforme - a dosimetric comparison
publisher BMC
series Radiation Oncology
issn 1748-717X
publishDate 2009-11-01
description <p>Abstract</p> <p>Background</p> <p>Biological brain tumor imaging using O-(2-[<sup>18</sup>F]fluoroethyl)-L-tyrosine (FET)-PET combined with inverse treatment planning for locally restricted dose escalation in patients with glioblastoma multiforme seems to be a promising approach.</p> <p>The aim of this study was to compare inverse with forward treatment planning for an integrated boost dose application in patients suffering from a glioblastoma multiforme, while biological target volumes are based on FET-PET and MRI data sets.</p> <p>Methods</p> <p>In 16 glioblastoma patients an intensity-modulated radiotherapy technique comprising an integrated boost (IB-IMRT) and a 3-dimensional conventional radiotherapy (3D-CRT) technique were generated for dosimetric comparison. FET-PET, MRI and treatment planning CT (P-CT) were co-registrated. The integrated boost volume (PTV1) was auto-contoured using a cut-off tumor-to-brain ratio (TBR) of ≥ 1.6 from FET-PET. PTV2 delineation was MRI-based. The total dose was prescribed to 72 and 60 Gy for PTV1 and PTV2, using daily fractions of 2.4 and 2 Gy.</p> <p>Results</p> <p>After auto-contouring of PTV1 a marked target shape complexity had an impact on the dosimetric outcome. Patients with 3-4 PTV1 subvolumes vs. a single volume revealed a significant decrease in mean dose (67.7 vs. 70.6 Gy). From convex to complex shaped PTV1 mean doses decreased from 71.3 Gy to 67.7 Gy. The homogeneity and conformity for PTV1 and PTV2 was significantly improved with IB-IMRT. With the use of IB-IMRT the minimum dose within PTV1 (61.1 vs. 57.4 Gy) and PTV2 (51.4 vs. 40.9 Gy) increased significantly, and the mean EUD for PTV2 was improved (59.9 vs. 55.3 Gy, p < 0.01). The EUD for PTV1 was only slightly improved (68.3 vs. 67.3 Gy). The EUD for the brain was equal with both planning techniques.</p> <p>Conclusion</p> <p>In the presented planning study the integrated boost concept based on inversely planned IB-IMRT is feasible. The FET-PET-based automatically contoured PTV1 can lead to very complex geometric configurations, limiting the achievable mean dose in the boost volume. With IB-IMRT a better homogeneity and conformity, compared to 3D-CRT, could be achieved.</p>
url http://www.ro-journal.com/content/4/1/57
work_keys_str_mv AT stoffelsgabriele integratedboostimrtor3dcrtusingfetpetbasedautocontouredtargetvolumedelineationforglioblastomamultiformeadosimetriccomparison
AT holyrichard integratedboostimrtor3dcrtusingfetpetbasedautocontouredtargetvolumedelineationforglioblastomamultiformeadosimetriccomparison
AT pinkawamichael integratedboostimrtor3dcrtusingfetpetbasedautocontouredtargetvolumedelineationforglioblastomamultiformeadosimetriccomparison
AT pirothmarcd integratedboostimrtor3dcrtusingfetpetbasedautocontouredtargetvolumedelineationforglioblastomamultiformeadosimetriccomparison
AT demirelcengiz integratedboostimrtor3dcrtusingfetpetbasedautocontouredtargetvolumedelineationforglioblastomamultiformeadosimetriccomparison
AT attiehcharbel integratedboostimrtor3dcrtusingfetpetbasedautocontouredtargetvolumedelineationforglioblastomamultiformeadosimetriccomparison
AT kaiserhansj integratedboostimrtor3dcrtusingfetpetbasedautocontouredtargetvolumedelineationforglioblastomamultiformeadosimetriccomparison
AT langenkarlj integratedboostimrtor3dcrtusingfetpetbasedautocontouredtargetvolumedelineationforglioblastomamultiformeadosimetriccomparison
AT eblemichaelj integratedboostimrtor3dcrtusingfetpetbasedautocontouredtargetvolumedelineationforglioblastomamultiformeadosimetriccomparison
_version_ 1725275368308342784