id doaj-bf4d75b6c01e42c18311fb2631bdba9c
record_format Article
spelling doaj-bf4d75b6c01e42c18311fb2631bdba9c2021-04-02T12:27:35ZengWileyThe Journal of Engineering2051-33052019-01-0110.1049/joe.2018.8543JOE.2018.8543Frequency stability control method considering limited EDCPSYi Hu0Xiaoru Wang1Dalin Chen2Yulong Che3School of Electrical Engineering, Southwest Jiaotong UniversitySchool of Electrical Engineering, Southwest Jiaotong UniversitySchool of Electrical Engineering, Southwest Jiaotong UniversitySchool of Electrical Engineering, Southwest Jiaotong UniversityAiming at the problem of frequency stability of the asynchronous AC/DC hybrid power grid, a prediction model of post-disturbance steady frequency is proposed, which considers the emergency DC power support (EDCPS) and the frequency response of AC grids on both sides of the high-voltage DC (HVDC) link. This post-disturbance steady frequency of both AC grids can be predicted quickly by utilising the wide area measurement system data, and the desired amount of EDCPS can be calculated directly by using the setting value of the steady frequency for the disturbed AC grid. Then this study considers the fact that the voltage level of the AC buses at both ends of the HVDC system will affect the operation modes of the HVDC system, resulting in the limited EDCPS. Therefore, a calculation method of the actual EDCPS command for steady frequency control is proposed. It can automatically identify the actual operation mode of the post-disturbance HVDC system and calculate the actual EDCPS command corresponding to the desired EDCPS value. Simulations of a typical two-area AC/DC hybrid power grid are carried out to validate the effectiveness of the proposed method.https://digital-library.theiet.org/content/journals/10.1049/joe.2018.8543power system controlcontrol system synthesishybrid power systemsHVDC power transmissionpower gridspower system measurementHVDC power convertorspower transmission controlfrequency controlfrequency stabilitypower system transient stabilityfrequency stability control methodasynchronous AC/DC hybrid power gridprediction modelpost-disturbance steady frequencyemergency DC power supportfrequency responseAC gridshigh-voltage DC linkwide area measurement system datadisturbed AC gridAC busescalculation methodactual EDCPS commandsteady frequency controlpost-disturbance HVDC systemdesired EDCPS valuetwo-area AC/DC hybrid power grid
collection DOAJ
language English
format Article
sources DOAJ
author Yi Hu
Xiaoru Wang
Dalin Chen
Yulong Che
spellingShingle Yi Hu
Xiaoru Wang
Dalin Chen
Yulong Che
Frequency stability control method considering limited EDCPS
The Journal of Engineering
power system control
control system synthesis
hybrid power systems
HVDC power transmission
power grids
power system measurement
HVDC power convertors
power transmission control
frequency control
frequency stability
power system transient stability
frequency stability control method
asynchronous AC/DC hybrid power grid
prediction model
post-disturbance steady frequency
emergency DC power support
frequency response
AC grids
high-voltage DC link
wide area measurement system data
disturbed AC grid
AC buses
calculation method
actual EDCPS command
steady frequency control
post-disturbance HVDC system
desired EDCPS value
two-area AC/DC hybrid power grid
author_facet Yi Hu
Xiaoru Wang
Dalin Chen
Yulong Che
author_sort Yi Hu
title Frequency stability control method considering limited EDCPS
title_short Frequency stability control method considering limited EDCPS
title_full Frequency stability control method considering limited EDCPS
title_fullStr Frequency stability control method considering limited EDCPS
title_full_unstemmed Frequency stability control method considering limited EDCPS
title_sort frequency stability control method considering limited edcps
publisher Wiley
series The Journal of Engineering
issn 2051-3305
publishDate 2019-01-01
description Aiming at the problem of frequency stability of the asynchronous AC/DC hybrid power grid, a prediction model of post-disturbance steady frequency is proposed, which considers the emergency DC power support (EDCPS) and the frequency response of AC grids on both sides of the high-voltage DC (HVDC) link. This post-disturbance steady frequency of both AC grids can be predicted quickly by utilising the wide area measurement system data, and the desired amount of EDCPS can be calculated directly by using the setting value of the steady frequency for the disturbed AC grid. Then this study considers the fact that the voltage level of the AC buses at both ends of the HVDC system will affect the operation modes of the HVDC system, resulting in the limited EDCPS. Therefore, a calculation method of the actual EDCPS command for steady frequency control is proposed. It can automatically identify the actual operation mode of the post-disturbance HVDC system and calculate the actual EDCPS command corresponding to the desired EDCPS value. Simulations of a typical two-area AC/DC hybrid power grid are carried out to validate the effectiveness of the proposed method.
topic power system control
control system synthesis
hybrid power systems
HVDC power transmission
power grids
power system measurement
HVDC power convertors
power transmission control
frequency control
frequency stability
power system transient stability
frequency stability control method
asynchronous AC/DC hybrid power grid
prediction model
post-disturbance steady frequency
emergency DC power support
frequency response
AC grids
high-voltage DC link
wide area measurement system data
disturbed AC grid
AC buses
calculation method
actual EDCPS command
steady frequency control
post-disturbance HVDC system
desired EDCPS value
two-area AC/DC hybrid power grid
url https://digital-library.theiet.org/content/journals/10.1049/joe.2018.8543
work_keys_str_mv AT yihu frequencystabilitycontrolmethodconsideringlimitededcps
AT xiaoruwang frequencystabilitycontrolmethodconsideringlimitededcps
AT dalinchen frequencystabilitycontrolmethodconsideringlimitededcps
AT yulongche frequencystabilitycontrolmethodconsideringlimitededcps
_version_ 1721568909645053952