Uncertainty Analysis for RadCalNet Instrumented Test Sites Using the Baotou Sites BTCN and BSCN as Examples

Vicarious calibration and validation techniques are important tools to ensure the longterm stability and intersensor consistency of satellite sensors making observations in the solarreflective spectral domain. Automated test sites, which have continuous in situ monitoring of both ground reflectance...

Full description

Bibliographic Details
Main Authors: Lingling Ma, Yongguang Zhao, Emma R. Woolliams, Caihong Dai, Ning Wang, Yaokai Liu, Ling Li, Xinhong Wang, Caixia Gao, Chuanrong Li, Lingli Tang
Format: Article
Language:English
Published: MDPI AG 2020-05-01
Series:Remote Sensing
Subjects:
Online Access:https://www.mdpi.com/2072-4292/12/11/1696
Description
Summary:Vicarious calibration and validation techniques are important tools to ensure the longterm stability and intersensor consistency of satellite sensors making observations in the solarreflective spectral domain. Automated test sites, which have continuous in situ monitoring of both ground reflectance and atmospheric conditions, can greatly increase the match-up possibilities for a wide range of space agency and commercial sensors. The Baotou calibration and validation test site in China provides operational highaccuracy and highstability vicarious calibration and validation for high spatial resolution solarreflective remotesensing sensors. Two sites, given the abbreviations BTCN (an artificial site) and BSCN (a natural sandy site), have been selected as reference sites for the Committee on Earth Observation Satellites radiometric calibration network (RadCalNet). RadCalNet requires sites to provide data in a consistent format but does not specify the required operational conditions for a RadCalNet site. The two Baotou sites are the only sites to date that make spectral measurements for their continuous operation. One of the core principles of RadCalNet is that each site should have a metrologically rigorous uncertainty budget which also describes the site’s traceability to the international system of units, the SI. This paper shows a formalized metrological approach to determining and documenting the uncertainty budget and traceability of a RadCalNet site. This approach follows the Guide to the Expression of Uncertainty in Measurement. The paper describes the uncertainty analysis for bottomofatmosphere and topofatmosphere reflectance in the spectral region from 400 to 1000 nm for the Baotou sites and gives preliminary results for the uncertainty propagating this to topofatmosphere reflectance.
ISSN:2072-4292