A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide
Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SpringerOpen
2021-01-01
|
Series: | Future Journal of Pharmaceutical Sciences |
Subjects: | |
Online Access: | https://doi.org/10.1186/s43094-020-00175-2 |
id |
doaj-bea9cf9fa4544cafb57f751babb350f8 |
---|---|
record_format |
Article |
spelling |
doaj-bea9cf9fa4544cafb57f751babb350f82021-01-17T12:53:33ZengSpringerOpenFuture Journal of Pharmaceutical Sciences2314-72532021-01-01711610.1186/s43094-020-00175-2A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromideIndhu Priya Mabbu0G. Sumathi1N. Devanna2Department of Chemistry, Jawaharlal Nehru Technological University AnantapurDepartment of Chemistry, Anantha Lakshmi Institute of Technology and SciencesDepartment of Chemistry, Jawaharlal Nehru Technological University AnantapurAbstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.https://doi.org/10.1186/s43094-020-00175-2Phenyl vinyl sulfoneEletriptanAtomic pressure chemical ionizationLimit of detection |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Indhu Priya Mabbu G. Sumathi N. Devanna |
spellingShingle |
Indhu Priya Mabbu G. Sumathi N. Devanna A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide Future Journal of Pharmaceutical Sciences Phenyl vinyl sulfone Eletriptan Atomic pressure chemical ionization Limit of detection |
author_facet |
Indhu Priya Mabbu G. Sumathi N. Devanna |
author_sort |
Indhu Priya Mabbu |
title |
A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide |
title_short |
A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide |
title_full |
A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide |
title_fullStr |
A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide |
title_full_unstemmed |
A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide |
title_sort |
novel lc-ms method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide |
publisher |
SpringerOpen |
series |
Future Journal of Pharmaceutical Sciences |
issn |
2314-7253 |
publishDate |
2021-01-01 |
description |
Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide. |
topic |
Phenyl vinyl sulfone Eletriptan Atomic pressure chemical ionization Limit of detection |
url |
https://doi.org/10.1186/s43094-020-00175-2 |
work_keys_str_mv |
AT indhupriyamabbu anovellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide AT gsumathi anovellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide AT ndevanna anovellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide AT indhupriyamabbu novellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide AT gsumathi novellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide AT ndevanna novellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide |
_version_ |
1724334311975419904 |