A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide

Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl...

Full description

Bibliographic Details
Main Authors: Indhu Priya Mabbu, G. Sumathi, N. Devanna
Format: Article
Language:English
Published: SpringerOpen 2021-01-01
Series:Future Journal of Pharmaceutical Sciences
Subjects:
Online Access:https://doi.org/10.1186/s43094-020-00175-2
id doaj-bea9cf9fa4544cafb57f751babb350f8
record_format Article
spelling doaj-bea9cf9fa4544cafb57f751babb350f82021-01-17T12:53:33ZengSpringerOpenFuture Journal of Pharmaceutical Sciences2314-72532021-01-01711610.1186/s43094-020-00175-2A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromideIndhu Priya Mabbu0G. Sumathi1N. Devanna2Department of Chemistry, Jawaharlal Nehru Technological University AnantapurDepartment of Chemistry, Anantha Lakshmi Institute of Technology and SciencesDepartment of Chemistry, Jawaharlal Nehru Technological University AnantapurAbstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.https://doi.org/10.1186/s43094-020-00175-2Phenyl vinyl sulfoneEletriptanAtomic pressure chemical ionizationLimit of detection
collection DOAJ
language English
format Article
sources DOAJ
author Indhu Priya Mabbu
G. Sumathi
N. Devanna
spellingShingle Indhu Priya Mabbu
G. Sumathi
N. Devanna
A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide
Future Journal of Pharmaceutical Sciences
Phenyl vinyl sulfone
Eletriptan
Atomic pressure chemical ionization
Limit of detection
author_facet Indhu Priya Mabbu
G. Sumathi
N. Devanna
author_sort Indhu Priya Mabbu
title A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide
title_short A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide
title_full A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide
title_fullStr A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide
title_full_unstemmed A novel LC-MS method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide
title_sort novel lc-ms method development and validation for the determination of phenyl vinyl sulfone in eletriptan hydrobromide
publisher SpringerOpen
series Future Journal of Pharmaceutical Sciences
issn 2314-7253
publishDate 2021-01-01
description Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.
topic Phenyl vinyl sulfone
Eletriptan
Atomic pressure chemical ionization
Limit of detection
url https://doi.org/10.1186/s43094-020-00175-2
work_keys_str_mv AT indhupriyamabbu anovellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide
AT gsumathi anovellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide
AT ndevanna anovellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide
AT indhupriyamabbu novellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide
AT gsumathi novellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide
AT ndevanna novellcmsmethoddevelopmentandvalidationforthedeterminationofphenylvinylsulfoneineletriptanhydrobromide
_version_ 1724334311975419904