Estimation of Insulin Resistance in Mexican Adults by the [13C]Glucose Breath Test Corrected for Endogenous Total CO2 Production
Objective. To evaluate the efficacy of the [13C]glucose breath test for measuring insulin resistance in Mexican adults with different glycemic states. Research Design and Methods. Fifty-eight adults underwent a [13C]glucose breath test with simultaneous measurement of total CO2 production by indirec...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2012-01-01
|
Series: | International Journal of Endocrinology |
Online Access: | http://dx.doi.org/10.1155/2012/907818 |
id |
doaj-bdfdbd2a4d824aff9ff32b12d7889e31 |
---|---|
record_format |
Article |
spelling |
doaj-bdfdbd2a4d824aff9ff32b12d7889e312020-11-24T23:00:51ZengHindawi LimitedInternational Journal of Endocrinology1687-83371687-83452012-01-01201210.1155/2012/907818907818Estimation of Insulin Resistance in Mexican Adults by the [13C]Glucose Breath Test Corrected for Endogenous Total CO2 ProductionErika Ibarra-Pastrana0Maria del Carmen Candia Plata1Gerardo Alvarez2Mauro E. Valencia3Nutrition Division, Centro de Investigación en Alimentacion y Desarrollo, A.C., MexicoDepartment of Medicine and Health Sciences, University of Sonora, Hermosillo, MexicoDepartment of Medicine and Health Sciences, University of Sonora, Hermosillo, MexicoNutrition Division, Centro de Investigación en Alimentacion y Desarrollo, A.C., MexicoObjective. To evaluate the efficacy of the [13C]glucose breath test for measuring insulin resistance in Mexican adults with different glycemic states. Research Design and Methods. Fifty-eight adults underwent a [13C]glucose breath test with simultaneous measurement of total CO2 production by indirect calorimetry, at baseline and 90 minutes after the ingestion of 15 g of dextrose and 25 mg of [13C]glucose. HOMA was used as a marker of insulin resistance. Results. We found an inverse correlation between HOMA and the breath test δ13CO2 (‰), r=-0.41 (P=0.001). After adjusting for total CO2 production, correlations between HOMA and fasting glucose were less strong but remained significant. An ROC curve was constructed using δ13CO2 (‰) and HOMA values; the cut-off point was 9.99‰ δ13CO2, corresponding to a sensitivity of 80.0 (95% CI: 51.9, 95.7) and a specificity of 67.4 (95% CI: 51.5, 80.9). Conclusions. The [13C]glucose breath test is a simple noninvasive procedure but was not sufficiently robust for an accurate diagnosis of insulin resistance. Our findings suggest that the test might be helpful in identifying individuals who are not IR, which in turn may contribute to improved diabetes prevention.http://dx.doi.org/10.1155/2012/907818 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Erika Ibarra-Pastrana Maria del Carmen Candia Plata Gerardo Alvarez Mauro E. Valencia |
spellingShingle |
Erika Ibarra-Pastrana Maria del Carmen Candia Plata Gerardo Alvarez Mauro E. Valencia Estimation of Insulin Resistance in Mexican Adults by the [13C]Glucose Breath Test Corrected for Endogenous Total CO2 Production International Journal of Endocrinology |
author_facet |
Erika Ibarra-Pastrana Maria del Carmen Candia Plata Gerardo Alvarez Mauro E. Valencia |
author_sort |
Erika Ibarra-Pastrana |
title |
Estimation of Insulin Resistance in Mexican Adults by the [13C]Glucose Breath Test Corrected for Endogenous Total CO2 Production |
title_short |
Estimation of Insulin Resistance in Mexican Adults by the [13C]Glucose Breath Test Corrected for Endogenous Total CO2 Production |
title_full |
Estimation of Insulin Resistance in Mexican Adults by the [13C]Glucose Breath Test Corrected for Endogenous Total CO2 Production |
title_fullStr |
Estimation of Insulin Resistance in Mexican Adults by the [13C]Glucose Breath Test Corrected for Endogenous Total CO2 Production |
title_full_unstemmed |
Estimation of Insulin Resistance in Mexican Adults by the [13C]Glucose Breath Test Corrected for Endogenous Total CO2 Production |
title_sort |
estimation of insulin resistance in mexican adults by the [13c]glucose breath test corrected for endogenous total co2 production |
publisher |
Hindawi Limited |
series |
International Journal of Endocrinology |
issn |
1687-8337 1687-8345 |
publishDate |
2012-01-01 |
description |
Objective. To evaluate the efficacy of the [13C]glucose breath test for measuring insulin resistance in Mexican adults with different glycemic states. Research Design and Methods. Fifty-eight adults underwent a [13C]glucose breath test with simultaneous measurement of total CO2 production by indirect calorimetry, at baseline and 90 minutes after the ingestion of 15 g of dextrose and 25 mg of [13C]glucose. HOMA was used as a marker of insulin resistance. Results. We found an inverse correlation between HOMA and the breath test δ13CO2 (‰), r=-0.41 (P=0.001). After adjusting for total CO2 production, correlations between HOMA and fasting glucose were less strong but remained significant. An ROC curve was constructed using δ13CO2 (‰) and HOMA values; the cut-off point was 9.99‰ δ13CO2, corresponding to a sensitivity of 80.0 (95% CI: 51.9, 95.7) and a specificity of 67.4 (95% CI: 51.5, 80.9). Conclusions. The [13C]glucose breath test is a simple noninvasive procedure but was not sufficiently robust for an accurate diagnosis of insulin resistance. Our findings suggest that the test might be helpful in identifying individuals who are not IR, which in turn may contribute to improved diabetes prevention. |
url |
http://dx.doi.org/10.1155/2012/907818 |
work_keys_str_mv |
AT erikaibarrapastrana estimationofinsulinresistanceinmexicanadultsbythe13cglucosebreathtestcorrectedforendogenoustotalco2production AT mariadelcarmencandiaplata estimationofinsulinresistanceinmexicanadultsbythe13cglucosebreathtestcorrectedforendogenoustotalco2production AT gerardoalvarez estimationofinsulinresistanceinmexicanadultsbythe13cglucosebreathtestcorrectedforendogenoustotalco2production AT mauroevalencia estimationofinsulinresistanceinmexicanadultsbythe13cglucosebreathtestcorrectedforendogenoustotalco2production |
_version_ |
1725641056322584576 |