PARAMETERS OPTIMIZATION OF HIGH FREQUENCY ULTRASONIC SYSTEM FOR WIRE BONDING
Mathematical equations for resonant frequency and impedance of ultrasonic transducer for wire bonding were proposed. Clamping optimization of bonding tool was determined due to modelling of resonant frequency and impedance for standard and high frequency ultrasonic vibrations in ultrasonic system. I...
Main Author: | |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Educational institution «Belarusian State University of Informatics and Radioelectronics»
2019-06-01
|
Series: | Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki |
Subjects: | |
Online Access: | https://doklady.bsuir.by/jour/article/view/843 |
id |
doaj-bdb06e2a7da34487afee66797823e37b |
---|---|
record_format |
Article |
spelling |
doaj-bdb06e2a7da34487afee66797823e37b2021-07-28T16:19:54ZrusEducational institution «Belarusian State University of Informatics and Radioelectronics»Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki1729-76482019-06-01013339842PARAMETERS OPTIMIZATION OF HIGH FREQUENCY ULTRASONIC SYSTEM FOR WIRE BONDINGI. B. Petuhov0УП «КБТЭМ-СО» ГНПО «ПЛАНАР»Mathematical equations for resonant frequency and impedance of ultrasonic transducer for wire bonding were proposed. Clamping optimization of bonding tool was determined due to modelling of resonant frequency and impedance for standard and high frequency ultrasonic vibrations in ultrasonic system. It was shown that proposed technique gives good fit to the experimental data.https://doklady.bsuir.by/jour/article/view/843ультразвуковая системаультразвуковой преобразовательволноводультразвуковая микросваркапроволочные выводымикроинструментимпедансчастота резонанса |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
I. B. Petuhov |
spellingShingle |
I. B. Petuhov PARAMETERS OPTIMIZATION OF HIGH FREQUENCY ULTRASONIC SYSTEM FOR WIRE BONDING Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki ультразвуковая система ультразвуковой преобразователь волновод ультразвуковая микросварка проволочные выводы микроинструмент импеданс частота резонанса |
author_facet |
I. B. Petuhov |
author_sort |
I. B. Petuhov |
title |
PARAMETERS OPTIMIZATION OF HIGH FREQUENCY ULTRASONIC SYSTEM FOR WIRE BONDING |
title_short |
PARAMETERS OPTIMIZATION OF HIGH FREQUENCY ULTRASONIC SYSTEM FOR WIRE BONDING |
title_full |
PARAMETERS OPTIMIZATION OF HIGH FREQUENCY ULTRASONIC SYSTEM FOR WIRE BONDING |
title_fullStr |
PARAMETERS OPTIMIZATION OF HIGH FREQUENCY ULTRASONIC SYSTEM FOR WIRE BONDING |
title_full_unstemmed |
PARAMETERS OPTIMIZATION OF HIGH FREQUENCY ULTRASONIC SYSTEM FOR WIRE BONDING |
title_sort |
parameters optimization of high frequency ultrasonic system for wire bonding |
publisher |
Educational institution «Belarusian State University of Informatics and Radioelectronics» |
series |
Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki |
issn |
1729-7648 |
publishDate |
2019-06-01 |
description |
Mathematical equations for resonant frequency and impedance of ultrasonic transducer for wire bonding were proposed. Clamping optimization of bonding tool was determined due to modelling of resonant frequency and impedance for standard and high frequency ultrasonic vibrations in ultrasonic system. It was shown that proposed technique gives good fit to the experimental data. |
topic |
ультразвуковая система ультразвуковой преобразователь волновод ультразвуковая микросварка проволочные выводы микроинструмент импеданс частота резонанса |
url |
https://doklady.bsuir.by/jour/article/view/843 |
work_keys_str_mv |
AT ibpetuhov parametersoptimizationofhighfrequencyultrasonicsystemforwirebonding |
_version_ |
1721267779744563200 |