A Novel Quantum Dots–Based Point of Care Test for Syphilis

<p>Abstract</p> <p>One-step lateral flow test is recommended as the first line screening of <it>syphilis</it> for primary healthcare settings in developing countries. However, it generally shows low sensitivity. We describe here the development of a novel fluorescent PO...

Full description

Bibliographic Details
Main Authors: Li Ding, Yang Hao, He Rong, Guo Qin, Wang Kan, Zhang Xueqing, Huang Peng, Cui Daxiang
Format: Article
Language:English
Published: SpringerOpen 2010-01-01
Series:Nanoscale Research Letters
Subjects:
Online Access:http://dx.doi.org/10.1007/s11671-010-9578-1
id doaj-bd71419b4bb244c789cbcf16362f2e26
record_format Article
spelling doaj-bd71419b4bb244c789cbcf16362f2e262020-11-24T20:56:25ZengSpringerOpenNanoscale Research Letters1931-75731556-276X2010-01-0155875881A Novel Quantum Dots&#8211;Based Point of Care Test for SyphilisLi DingYang HaoHe RongGuo QinWang KanZhang XueqingHuang PengCui Daxiang<p>Abstract</p> <p>One-step lateral flow test is recommended as the first line screening of <it>syphilis</it> for primary healthcare settings in developing countries. However, it generally shows low sensitivity. We describe here the development of a novel fluorescent POC (Point Of Care) test method to be used for screening for syphilis. The method was designed to combine the rapidness of lateral flow test and sensitiveness of fluorescent method. 50 <it>syphilis</it>-positive specimens and 50 healthy specimens conformed by <it>Treponema pallidum</it> particle agglutination (TPPA) were tested with Quantum Dot-labeled and colloidal gold-labeled lateral flow test strips, respectively. The results showed that both sensitivity and specificity of the quantum dots&#8211;based method reached up to 100% (95% confidence interval [CI], 91&#8211;100%), while those of the colloidal gold-based method were 82% (95% CI, 68&#8211;91%) and 100% (95% CI, 91&#8211;100%), respectively. In addition, the naked-eye detection limit of quantum dot&#8211;based method could achieve 2 ng/ml of anti-TP47 polyclonal antibodies purified by affinity chromatography with TP47 antigen, which was tenfold higher than that of colloidal gold&#8211;based method. In conclusion, the quantum dots were found to be suitable for labels of lateral flow test strip. Its ease of use, sensitiveness and low cost make it well-suited for population-based on-the-site syphilis screening.</p> http://dx.doi.org/10.1007/s11671-010-9578-1SyphilisLateral flowDiagnosticsQuantum dotsNanomaterial
collection DOAJ
language English
format Article
sources DOAJ
author Li Ding
Yang Hao
He Rong
Guo Qin
Wang Kan
Zhang Xueqing
Huang Peng
Cui Daxiang
spellingShingle Li Ding
Yang Hao
He Rong
Guo Qin
Wang Kan
Zhang Xueqing
Huang Peng
Cui Daxiang
A Novel Quantum Dots&#8211;Based Point of Care Test for Syphilis
Nanoscale Research Letters
Syphilis
Lateral flow
Diagnostics
Quantum dots
Nanomaterial
author_facet Li Ding
Yang Hao
He Rong
Guo Qin
Wang Kan
Zhang Xueqing
Huang Peng
Cui Daxiang
author_sort Li Ding
title A Novel Quantum Dots&#8211;Based Point of Care Test for Syphilis
title_short A Novel Quantum Dots&#8211;Based Point of Care Test for Syphilis
title_full A Novel Quantum Dots&#8211;Based Point of Care Test for Syphilis
title_fullStr A Novel Quantum Dots&#8211;Based Point of Care Test for Syphilis
title_full_unstemmed A Novel Quantum Dots&#8211;Based Point of Care Test for Syphilis
title_sort novel quantum dots&#8211;based point of care test for syphilis
publisher SpringerOpen
series Nanoscale Research Letters
issn 1931-7573
1556-276X
publishDate 2010-01-01
description <p>Abstract</p> <p>One-step lateral flow test is recommended as the first line screening of <it>syphilis</it> for primary healthcare settings in developing countries. However, it generally shows low sensitivity. We describe here the development of a novel fluorescent POC (Point Of Care) test method to be used for screening for syphilis. The method was designed to combine the rapidness of lateral flow test and sensitiveness of fluorescent method. 50 <it>syphilis</it>-positive specimens and 50 healthy specimens conformed by <it>Treponema pallidum</it> particle agglutination (TPPA) were tested with Quantum Dot-labeled and colloidal gold-labeled lateral flow test strips, respectively. The results showed that both sensitivity and specificity of the quantum dots&#8211;based method reached up to 100% (95% confidence interval [CI], 91&#8211;100%), while those of the colloidal gold-based method were 82% (95% CI, 68&#8211;91%) and 100% (95% CI, 91&#8211;100%), respectively. In addition, the naked-eye detection limit of quantum dot&#8211;based method could achieve 2 ng/ml of anti-TP47 polyclonal antibodies purified by affinity chromatography with TP47 antigen, which was tenfold higher than that of colloidal gold&#8211;based method. In conclusion, the quantum dots were found to be suitable for labels of lateral flow test strip. Its ease of use, sensitiveness and low cost make it well-suited for population-based on-the-site syphilis screening.</p>
topic Syphilis
Lateral flow
Diagnostics
Quantum dots
Nanomaterial
url http://dx.doi.org/10.1007/s11671-010-9578-1
work_keys_str_mv AT liding anovelquantumdots8211basedpointofcaretestforsyphilis
AT yanghao anovelquantumdots8211basedpointofcaretestforsyphilis
AT herong anovelquantumdots8211basedpointofcaretestforsyphilis
AT guoqin anovelquantumdots8211basedpointofcaretestforsyphilis
AT wangkan anovelquantumdots8211basedpointofcaretestforsyphilis
AT zhangxueqing anovelquantumdots8211basedpointofcaretestforsyphilis
AT huangpeng anovelquantumdots8211basedpointofcaretestforsyphilis
AT cuidaxiang anovelquantumdots8211basedpointofcaretestforsyphilis
AT liding novelquantumdots8211basedpointofcaretestforsyphilis
AT yanghao novelquantumdots8211basedpointofcaretestforsyphilis
AT herong novelquantumdots8211basedpointofcaretestforsyphilis
AT guoqin novelquantumdots8211basedpointofcaretestforsyphilis
AT wangkan novelquantumdots8211basedpointofcaretestforsyphilis
AT zhangxueqing novelquantumdots8211basedpointofcaretestforsyphilis
AT huangpeng novelquantumdots8211basedpointofcaretestforsyphilis
AT cuidaxiang novelquantumdots8211basedpointofcaretestforsyphilis
_version_ 1716789768052801536