Comparison of body fat using various bioelectrical impedance analyzers in university students

Background: At present, the portfolio of devices using the bioelectrical impedance (BIA) method is continuously expanding as a result of the wide use of this method in the field as measurements by this method are fast and staff training is simple and reasonably priced. Nonetheless, the problem is th...

Full description

Bibliographic Details
Main Authors: Petr Kutáč, Miroslav Kopecký
Format: Article
Language:English
Published: Palacký University Olomouc 2015-12-01
Series:Acta Gymnica
Subjects:
Online Access:http://gymnica.upol.cz/artkey/gym-201504-0003_Comparison_of_body_fat_using_various_bioelectrical_impedance_analyzers_in_university_students.php
id doaj-bd6eafbfa52f46f483d095545985162d
record_format Article
spelling doaj-bd6eafbfa52f46f483d095545985162d2020-11-24T20:53:54ZengPalacký University OlomoucActa Gymnica2336-49122336-49202015-12-0145417718610.5507/ag.2015.021gym-201504-0003Comparison of body fat using various bioelectrical impedance analyzers in university studentsPetr Kutáč0Miroslav Kopecký1Human Motion Diagnostics Center, University of Ostrava, Ostrava, Czech Republic;Faculty of Health Sciences, Palacký University Olomouc, Olomouc, Czech RepublicBackground: At present, the portfolio of devices using the bioelectrical impedance (BIA) method is continuously expanding as a result of the wide use of this method in the field as measurements by this method are fast and staff training is simple and reasonably priced. Nonetheless, the problem is that despite using the same method, bioimpedance analyzers can differ in many parameters. They use different electric current frequencies, a different number of electrodes and the electric current may be conducted through different parts of the body.Objective: The main objective of the study is to compare and evaluate the differences of values of the analysis of the body fat of university students measured by BIA analyzers that differ in the applied electric current frequency, number of electrodes and flow of the electric current through the individual body parts.Methods: The research included 125 participants (70 male and 55 female). The measurements were taken by the following analyzers: Tanita 418 MA, InBody 720, InBody R20 and Omron BF 300.Results: The differences in the mean values of the body fat representation between the used analyzers in men ranged from 0.1 to 3.4% and from 0.0 to 2.4 kg, in women from 0.5 to 6.5% and from 0.4 to 3.8 kg in relation to the used analyzer.Conclusions: In men with regular physical activity, the values measured by InBody R20 were statistically and practically different. The analyzer measured higher values that other analyzers. In women, there were statistically and practically significant differences in the values measured by Omron BF 300. This analyzer measured lower values than other analyzers.http://gymnica.upol.cz/artkey/gym-201504-0003_Comparison_of_body_fat_using_various_bioelectrical_impedance_analyzers_in_university_students.phpadipose tissueyoung adultsingle frequency analyzermulti frequency analyzerBland-Altman analysis
collection DOAJ
language English
format Article
sources DOAJ
author Petr Kutáč
Miroslav Kopecký
spellingShingle Petr Kutáč
Miroslav Kopecký
Comparison of body fat using various bioelectrical impedance analyzers in university students
Acta Gymnica
adipose tissue
young adult
single frequency analyzer
multi frequency analyzer
Bland-Altman analysis
author_facet Petr Kutáč
Miroslav Kopecký
author_sort Petr Kutáč
title Comparison of body fat using various bioelectrical impedance analyzers in university students
title_short Comparison of body fat using various bioelectrical impedance analyzers in university students
title_full Comparison of body fat using various bioelectrical impedance analyzers in university students
title_fullStr Comparison of body fat using various bioelectrical impedance analyzers in university students
title_full_unstemmed Comparison of body fat using various bioelectrical impedance analyzers in university students
title_sort comparison of body fat using various bioelectrical impedance analyzers in university students
publisher Palacký University Olomouc
series Acta Gymnica
issn 2336-4912
2336-4920
publishDate 2015-12-01
description Background: At present, the portfolio of devices using the bioelectrical impedance (BIA) method is continuously expanding as a result of the wide use of this method in the field as measurements by this method are fast and staff training is simple and reasonably priced. Nonetheless, the problem is that despite using the same method, bioimpedance analyzers can differ in many parameters. They use different electric current frequencies, a different number of electrodes and the electric current may be conducted through different parts of the body.Objective: The main objective of the study is to compare and evaluate the differences of values of the analysis of the body fat of university students measured by BIA analyzers that differ in the applied electric current frequency, number of electrodes and flow of the electric current through the individual body parts.Methods: The research included 125 participants (70 male and 55 female). The measurements were taken by the following analyzers: Tanita 418 MA, InBody 720, InBody R20 and Omron BF 300.Results: The differences in the mean values of the body fat representation between the used analyzers in men ranged from 0.1 to 3.4% and from 0.0 to 2.4 kg, in women from 0.5 to 6.5% and from 0.4 to 3.8 kg in relation to the used analyzer.Conclusions: In men with regular physical activity, the values measured by InBody R20 were statistically and practically different. The analyzer measured higher values that other analyzers. In women, there were statistically and practically significant differences in the values measured by Omron BF 300. This analyzer measured lower values than other analyzers.
topic adipose tissue
young adult
single frequency analyzer
multi frequency analyzer
Bland-Altman analysis
url http://gymnica.upol.cz/artkey/gym-201504-0003_Comparison_of_body_fat_using_various_bioelectrical_impedance_analyzers_in_university_students.php
work_keys_str_mv AT petrkutac comparisonofbodyfatusingvariousbioelectricalimpedanceanalyzersinuniversitystudents
AT miroslavkopecky comparisonofbodyfatusingvariousbioelectricalimpedanceanalyzersinuniversitystudents
_version_ 1716795822502313984