Simultaneous detection of Hepatitis B virus and Hepatitis C virus in human plasma using Taq-man chemistry

Designing a rapid, reliable and sensitive assay, for detection of hepatitis B virus and Hepatitis C virus variants by real-time PCR, is challenging at best. A recent approach for quantifying the viral load using the sensitive fluorescence principle, was used in this study. A total of 350 samples we...

Full description

Bibliographic Details
Main Authors: Khaja M N, Mohammed Aejaz Habeeb, Vishnupriya S, Ramachandra V V, Madhavi C, Rahmathulla S, Naresh Kumar Y
Format: Article
Language:English
Published: Deccan College of Medical Sciences 2011-07-01
Series:Journal of Medical and Allied Sciences
Subjects:
Online Access:http://www.jmas.in/2ndissue/JMAS%202nd%20issue%20PDF%20for%20Print/Simultaneous%20detection%20of%20Hepatitis%20B%20virus%20and%20Hepatitis%20C%20virus%20in%20human%20plasma%20using%20taqman%20chemistry.pdf
id doaj-bd12b675cb744f6e8a1f63260d320e59
record_format Article
spelling doaj-bd12b675cb744f6e8a1f63260d320e592020-11-25T02:40:42ZengDeccan College of Medical SciencesJournal of Medical and Allied Sciences2231-16962231-170X2011-07-01126973Simultaneous detection of Hepatitis B virus and Hepatitis C virus in human plasma using Taq-man chemistryKhaja M NMohammed Aejaz HabeebVishnupriya SRamachandra V VMadhavi CRahmathulla SNaresh Kumar YDesigning a rapid, reliable and sensitive assay, for detection of hepatitis B virus and Hepatitis C virus variants by real-time PCR, is challenging at best. A recent approach for quantifying the viral load using the sensitive fluorescence principle, was used in this study. A total of 350 samples were collected from outpatient unit, Center for Liver Research and Diagnostics (CLRD). Complete Human HBV DNA and HCV sequences were obtained from the National Centre for Biotechnology Information (NCBI); primers and probes were designed and synthesized from core, surface and x region of Hepatitis B and UTR region of HCV. Real-time based detection was done, using standard kit and in-house generated standards and RT-PCR protocols. A standard curve was generated by using the Smart Cycler II software and serial dilution 102 to 108 of cloned viral regions, the calibration curve was linear in a range from 102 to108 cp/ml for both HBV and HCV, with R2 value of 0.999 and 0.995. Out of 100 predetermined HCV negative samples, 02 samples were found positive with in-house developed RT-PCR assay, the positivity of this sample was confirmed by sequencing the amplified product. Low cost of this assay procedure and précised sample volume will permit the assay to be implemented for routine screening of Hepatitis B and C virus mono-infection and co-infection using Real Time PCR , Nucleic acid Chip technology and Fluorescent End Point detection systems. This assay is reproducible showing limited inter and intra assay variability. Our results correlated well with the standard kit for HBV and HCV virus monitor.http://www.jmas.in/2ndissue/JMAS%202nd%20issue%20PDF%20for%20Print/Simultaneous%20detection%20of%20Hepatitis%20B%20virus%20and%20Hepatitis%20C%20virus%20in%20human%20plasma%20using%20taqman%20chemistry.pdfHepatitis B virushepatitis C virusnucleic acid testreal-time PCR
collection DOAJ
language English
format Article
sources DOAJ
author Khaja M N
Mohammed Aejaz Habeeb
Vishnupriya S
Ramachandra V V
Madhavi C
Rahmathulla S
Naresh Kumar Y
spellingShingle Khaja M N
Mohammed Aejaz Habeeb
Vishnupriya S
Ramachandra V V
Madhavi C
Rahmathulla S
Naresh Kumar Y
Simultaneous detection of Hepatitis B virus and Hepatitis C virus in human plasma using Taq-man chemistry
Journal of Medical and Allied Sciences
Hepatitis B virus
hepatitis C virus
nucleic acid test
real-time PCR
author_facet Khaja M N
Mohammed Aejaz Habeeb
Vishnupriya S
Ramachandra V V
Madhavi C
Rahmathulla S
Naresh Kumar Y
author_sort Khaja M N
title Simultaneous detection of Hepatitis B virus and Hepatitis C virus in human plasma using Taq-man chemistry
title_short Simultaneous detection of Hepatitis B virus and Hepatitis C virus in human plasma using Taq-man chemistry
title_full Simultaneous detection of Hepatitis B virus and Hepatitis C virus in human plasma using Taq-man chemistry
title_fullStr Simultaneous detection of Hepatitis B virus and Hepatitis C virus in human plasma using Taq-man chemistry
title_full_unstemmed Simultaneous detection of Hepatitis B virus and Hepatitis C virus in human plasma using Taq-man chemistry
title_sort simultaneous detection of hepatitis b virus and hepatitis c virus in human plasma using taq-man chemistry
publisher Deccan College of Medical Sciences
series Journal of Medical and Allied Sciences
issn 2231-1696
2231-170X
publishDate 2011-07-01
description Designing a rapid, reliable and sensitive assay, for detection of hepatitis B virus and Hepatitis C virus variants by real-time PCR, is challenging at best. A recent approach for quantifying the viral load using the sensitive fluorescence principle, was used in this study. A total of 350 samples were collected from outpatient unit, Center for Liver Research and Diagnostics (CLRD). Complete Human HBV DNA and HCV sequences were obtained from the National Centre for Biotechnology Information (NCBI); primers and probes were designed and synthesized from core, surface and x region of Hepatitis B and UTR region of HCV. Real-time based detection was done, using standard kit and in-house generated standards and RT-PCR protocols. A standard curve was generated by using the Smart Cycler II software and serial dilution 102 to 108 of cloned viral regions, the calibration curve was linear in a range from 102 to108 cp/ml for both HBV and HCV, with R2 value of 0.999 and 0.995. Out of 100 predetermined HCV negative samples, 02 samples were found positive with in-house developed RT-PCR assay, the positivity of this sample was confirmed by sequencing the amplified product. Low cost of this assay procedure and précised sample volume will permit the assay to be implemented for routine screening of Hepatitis B and C virus mono-infection and co-infection using Real Time PCR , Nucleic acid Chip technology and Fluorescent End Point detection systems. This assay is reproducible showing limited inter and intra assay variability. Our results correlated well with the standard kit for HBV and HCV virus monitor.
topic Hepatitis B virus
hepatitis C virus
nucleic acid test
real-time PCR
url http://www.jmas.in/2ndissue/JMAS%202nd%20issue%20PDF%20for%20Print/Simultaneous%20detection%20of%20Hepatitis%20B%20virus%20and%20Hepatitis%20C%20virus%20in%20human%20plasma%20using%20taqman%20chemistry.pdf
work_keys_str_mv AT khajamn simultaneousdetectionofhepatitisbvirusandhepatitiscvirusinhumanplasmausingtaqmanchemistry
AT mohammedaejazhabeeb simultaneousdetectionofhepatitisbvirusandhepatitiscvirusinhumanplasmausingtaqmanchemistry
AT vishnupriyas simultaneousdetectionofhepatitisbvirusandhepatitiscvirusinhumanplasmausingtaqmanchemistry
AT ramachandravv simultaneousdetectionofhepatitisbvirusandhepatitiscvirusinhumanplasmausingtaqmanchemistry
AT madhavic simultaneousdetectionofhepatitisbvirusandhepatitiscvirusinhumanplasmausingtaqmanchemistry
AT rahmathullas simultaneousdetectionofhepatitisbvirusandhepatitiscvirusinhumanplasmausingtaqmanchemistry
AT nareshkumary simultaneousdetectionofhepatitisbvirusandhepatitiscvirusinhumanplasmausingtaqmanchemistry
_version_ 1724780226408349696