THERMAL PERFORMANCE OF FLAT PLATE SOLAR COLLECTOR
In this paper, a theoretical and experimental studyof flat platesolar water collector with reflectors.A mathematical model based on energy balance equations saw the thermal behavior of the collector is investigated. The experimental test was made at the unit research applies in renewable energy (URA...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Oradea
2017-06-01
|
Series: | Journal of Sustainable Energy |
Subjects: | |
Online Access: | http://www.energy-cie.ro/archives/2017/nr_2/v8-n2-2.pdf |
Summary: | In this paper, a theoretical and experimental studyof flat platesolar water collector with reflectors.A mathematical model based on energy balance equations saw the thermal behavior of the collector is investigated. The experimental test was made at the unit research applies in renewable energy (URAER) located in southern Algeria.An increase of 23% for solar radiation incident on the collector surface with the addition of the planers reflectors in the day of May, this increase causes an improvement of the performance of the collector,the fluid temperature increases with an average of 5%. Thetests conducted on the flat plate solar water collector in open circuit enabled the determination of thermal performance of the collector by estimating the daily output The thermal efficiency of the collector ranges from 1% -63% during the day, a mean value of 36%obtained. |
---|---|
ISSN: | 2067-5534 2067-5534 |