Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower

CT technology and image reconstruction were used to obtain cross-sectional density distribution images about simulation tower in laboratory, and then this technology was evaluated. For the 1 m diameter of the simulation tower and the 10 cm diameter container inside, the density resolution was in the...

Full description

Bibliographic Details
Main Author: WANG Lu-wei1,2;GAO Xiang1
Format: Article
Language:zho
Published: Editorial Board of Journal of Isotopes 2017-02-01
Series:Journal of Isotopes
Subjects:
Online Access:http://www.tws.org.cn/CN/abstract/abstract1708.shtml
id doaj-bcaec6344a33490dba14030f4b4094f9
record_format Article
spelling doaj-bcaec6344a33490dba14030f4b4094f92020-11-25T02:19:45ZzhoEditorial Board of Journal of IsotopesJournal of Isotopes1000-75121000-75122017-02-013029510210.7538/tws.2016.youxian.029Laboratory Experimental Evaluation of the Cross-section Image of Chemical TowerWANG Lu-wei1,2;GAO Xiang1CT technology and image reconstruction were used to obtain cross-sectional density distribution images about simulation tower in laboratory, and then this technology was evaluated. For the 1 m diameter of the simulation tower and the 10 cm diameter container inside, the density resolution was in the 5%~10% and the spatial resolution could reach 0.25 pairs/cm (lp/cm).http://www.tws.org.cn/CN/abstract/abstract1708.shtmlchemical tower ct spatial resolution the density resolution
collection DOAJ
language zho
format Article
sources DOAJ
author WANG Lu-wei1,2;GAO Xiang1
spellingShingle WANG Lu-wei1,2;GAO Xiang1
Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower
Journal of Isotopes
chemical tower ct spatial resolution the density resolution
author_facet WANG Lu-wei1,2;GAO Xiang1
author_sort WANG Lu-wei1,2;GAO Xiang1
title Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower
title_short Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower
title_full Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower
title_fullStr Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower
title_full_unstemmed Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower
title_sort laboratory experimental evaluation of the cross-section image of chemical tower
publisher Editorial Board of Journal of Isotopes
series Journal of Isotopes
issn 1000-7512
1000-7512
publishDate 2017-02-01
description CT technology and image reconstruction were used to obtain cross-sectional density distribution images about simulation tower in laboratory, and then this technology was evaluated. For the 1 m diameter of the simulation tower and the 10 cm diameter container inside, the density resolution was in the 5%~10% and the spatial resolution could reach 0.25 pairs/cm (lp/cm).
topic chemical tower ct spatial resolution the density resolution
url http://www.tws.org.cn/CN/abstract/abstract1708.shtml
work_keys_str_mv AT wangluwei12gaoxiang1 laboratoryexperimentalevaluationofthecrosssectionimageofchemicaltower
_version_ 1724874539572133888