Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower
CT technology and image reconstruction were used to obtain cross-sectional density distribution images about simulation tower in laboratory, and then this technology was evaluated. For the 1 m diameter of the simulation tower and the 10 cm diameter container inside, the density resolution was in the...
Main Author: | |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Board of Journal of Isotopes
2017-02-01
|
Series: | Journal of Isotopes |
Subjects: | |
Online Access: | http://www.tws.org.cn/CN/abstract/abstract1708.shtml |
id |
doaj-bcaec6344a33490dba14030f4b4094f9 |
---|---|
record_format |
Article |
spelling |
doaj-bcaec6344a33490dba14030f4b4094f92020-11-25T02:19:45ZzhoEditorial Board of Journal of IsotopesJournal of Isotopes1000-75121000-75122017-02-013029510210.7538/tws.2016.youxian.029Laboratory Experimental Evaluation of the Cross-section Image of Chemical TowerWANG Lu-wei1,2;GAO Xiang1CT technology and image reconstruction were used to obtain cross-sectional density distribution images about simulation tower in laboratory, and then this technology was evaluated. For the 1 m diameter of the simulation tower and the 10 cm diameter container inside, the density resolution was in the 5%~10% and the spatial resolution could reach 0.25 pairs/cm (lp/cm).http://www.tws.org.cn/CN/abstract/abstract1708.shtmlchemical tower ct spatial resolution the density resolution |
collection |
DOAJ |
language |
zho |
format |
Article |
sources |
DOAJ |
author |
WANG Lu-wei1,2;GAO Xiang1 |
spellingShingle |
WANG Lu-wei1,2;GAO Xiang1 Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower Journal of Isotopes chemical tower ct spatial resolution the density resolution |
author_facet |
WANG Lu-wei1,2;GAO Xiang1 |
author_sort |
WANG Lu-wei1,2;GAO Xiang1 |
title |
Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower |
title_short |
Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower |
title_full |
Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower |
title_fullStr |
Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower |
title_full_unstemmed |
Laboratory Experimental Evaluation of the Cross-section Image of Chemical Tower |
title_sort |
laboratory experimental evaluation of the cross-section image of chemical tower |
publisher |
Editorial Board of Journal of Isotopes |
series |
Journal of Isotopes |
issn |
1000-7512 1000-7512 |
publishDate |
2017-02-01 |
description |
CT technology and image reconstruction were used to obtain cross-sectional density distribution images about simulation tower in laboratory, and then this technology was evaluated. For the 1 m diameter of the simulation tower and the 10 cm diameter container inside, the density resolution was in the 5%~10% and the spatial resolution could reach 0.25 pairs/cm (lp/cm). |
topic |
chemical tower ct spatial resolution the density resolution |
url |
http://www.tws.org.cn/CN/abstract/abstract1708.shtml |
work_keys_str_mv |
AT wangluwei12gaoxiang1 laboratoryexperimentalevaluationofthecrosssectionimageofchemicaltower |
_version_ |
1724874539572133888 |