Effects of Gaps Between Side-Walls and 60∘ Ribs on the Heat Transfer and Rib Induced Secondary Flow Inside a Stationary and Rotating Cooling Channel

The present study investigates the effects of gaps between the side-walls and 60∘ ribs on the local heat transfer distribution between two consecutive ribs. The heat transfer and flow visualization experiments were carried out inside a straight rib-roughened duct with the ribs mounted on two opposit...

Full description

Bibliographic Details
Main Authors: Robert Kiml, Sadanari Mochizuki, Akira Murata
Format: Article
Language:English
Published: Hindawi Limited 2001-01-01
Series:International Journal of Rotating Machinery
Subjects:
Online Access:http://dx.doi.org/10.1155/S1023621X01000379