Analysis of Equivalent Inductance of Three-phase Induction Motors in the Switching Frequency Range
The equivalent inductance of three-phase induction motors is experimentally investigated in this paper, with particular reference to the frequency range from 1 kHz to 20 kHz, typical for the switching frequency in inverter-fed electrical drives. The equivalent inductance is a basic parameter when de...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-01-01
|
Series: | Electronics |
Subjects: | |
Online Access: | https://www.mdpi.com/2079-9292/8/2/120 |
id |
doaj-bc2430ed4a0f494faa0686ac8bfa6511 |
---|---|
record_format |
Article |
spelling |
doaj-bc2430ed4a0f494faa0686ac8bfa65112020-11-25T00:41:59ZengMDPI AGElectronics2079-92922019-01-018212010.3390/electronics8020120electronics8020120Analysis of Equivalent Inductance of Three-phase Induction Motors in the Switching Frequency RangeMilan Srndovic0Rastko Fišer1Gabriele Grandi2Department of Electrical, Electronic, and Information Engineering, University of Bologna, 40136 Bologna, ItalyDepartment of Mechatronics, Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, SloveniaDepartment of Electrical, Electronic, and Information Engineering, University of Bologna, 40136 Bologna, ItalyThe equivalent inductance of three-phase induction motors is experimentally investigated in this paper, with particular reference to the frequency range from 1 kHz to 20 kHz, typical for the switching frequency in inverter-fed electrical drives. The equivalent inductance is a basic parameter when determining the inverter-motor current distortion introduced by switching modulation, such as rms of current ripple, peak-to-peak current ripple amplitude, total harmonic distortion (THD), and synthesis of the optimal PWM strategy to minimize the THD itself. In case of squirrel-cage rotors, the experimental evidence shows that the equivalent inductance cannot be considered constant in the frequency range up to 20 kHz, and it considerably differs from the value measured at 50 Hz. This frequency-dependent behaviour can be justified mainly by the skin effect in rotor bars affecting the rotor leakage inductance in the considered frequency range. Experimental results are presented for a set of squirrel-cage induction motors with different rated power and one wound-rotor motor in order to emphasize the aforesaid phenomenon. The measurements were carried out by a three-phase sinusoidal generator with the maximum operating frequency of 5 kHz and a voltage source inverter operating in the six-step mode with the frequency up to 20 kHz.https://www.mdpi.com/2079-9292/8/2/120equivalent inductanceleakage inductanceswitching frequency modellinginduction motorcurrent switching ripple |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Milan Srndovic Rastko Fišer Gabriele Grandi |
spellingShingle |
Milan Srndovic Rastko Fišer Gabriele Grandi Analysis of Equivalent Inductance of Three-phase Induction Motors in the Switching Frequency Range Electronics equivalent inductance leakage inductance switching frequency modelling induction motor current switching ripple |
author_facet |
Milan Srndovic Rastko Fišer Gabriele Grandi |
author_sort |
Milan Srndovic |
title |
Analysis of Equivalent Inductance of Three-phase Induction Motors in the Switching Frequency Range |
title_short |
Analysis of Equivalent Inductance of Three-phase Induction Motors in the Switching Frequency Range |
title_full |
Analysis of Equivalent Inductance of Three-phase Induction Motors in the Switching Frequency Range |
title_fullStr |
Analysis of Equivalent Inductance of Three-phase Induction Motors in the Switching Frequency Range |
title_full_unstemmed |
Analysis of Equivalent Inductance of Three-phase Induction Motors in the Switching Frequency Range |
title_sort |
analysis of equivalent inductance of three-phase induction motors in the switching frequency range |
publisher |
MDPI AG |
series |
Electronics |
issn |
2079-9292 |
publishDate |
2019-01-01 |
description |
The equivalent inductance of three-phase induction motors is experimentally investigated in this paper, with particular reference to the frequency range from 1 kHz to 20 kHz, typical for the switching frequency in inverter-fed electrical drives. The equivalent inductance is a basic parameter when determining the inverter-motor current distortion introduced by switching modulation, such as rms of current ripple, peak-to-peak current ripple amplitude, total harmonic distortion (THD), and synthesis of the optimal PWM strategy to minimize the THD itself. In case of squirrel-cage rotors, the experimental evidence shows that the equivalent inductance cannot be considered constant in the frequency range up to 20 kHz, and it considerably differs from the value measured at 50 Hz. This frequency-dependent behaviour can be justified mainly by the skin effect in rotor bars affecting the rotor leakage inductance in the considered frequency range. Experimental results are presented for a set of squirrel-cage induction motors with different rated power and one wound-rotor motor in order to emphasize the aforesaid phenomenon. The measurements were carried out by a three-phase sinusoidal generator with the maximum operating frequency of 5 kHz and a voltage source inverter operating in the six-step mode with the frequency up to 20 kHz. |
topic |
equivalent inductance leakage inductance switching frequency modelling induction motor current switching ripple |
url |
https://www.mdpi.com/2079-9292/8/2/120 |
work_keys_str_mv |
AT milansrndovic analysisofequivalentinductanceofthreephaseinductionmotorsintheswitchingfrequencyrange AT rastkofiser analysisofequivalentinductanceofthreephaseinductionmotorsintheswitchingfrequencyrange AT gabrielegrandi analysisofequivalentinductanceofthreephaseinductionmotorsintheswitchingfrequencyrange |
_version_ |
1725284562974539776 |