Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument
Peracetic acid (PAA) is widely used as a sterilizing/disinfecting agent, and, in endodontics, it has been introduced as a promising irrigant in root canal treatment. It has been used at different concentrations to achieve various functions. However, endodontic instruments in contact with PAA of a ce...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2021-01-01
|
Series: | International Journal of Dentistry |
Online Access: | http://dx.doi.org/10.1155/2021/6676005 |
id |
doaj-bbf70dd2d0b3408d8b9b1ea7cfd2f1de |
---|---|
record_format |
Article |
spelling |
doaj-bbf70dd2d0b3408d8b9b1ea7cfd2f1de2021-02-15T12:53:02ZengHindawi LimitedInternational Journal of Dentistry1687-87281687-87362021-01-01202110.1155/2021/66760056676005Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic InstrumentSuhad Jabbar Hamed Al-Nasrawi0Zuha Ayad Jaber1Nibrass Talib Al-Quraine2Abtesam Imhemed Aljdaimi3Sattar Jabbar Abdul-Zahra Al-Hmedat4Saleh Zidan5Julfikar Haider6Department of Conservative Dentistry, Faculty of Dentistry, University of Kufa, Najaf, IraqDepartment of Conservative Dentistry, Faculty of Dentistry, University of Kufa, Najaf, IraqDepartment of Conservative Dentistry, Faculty of Dentistry, University of Kufa, Najaf, IraqCollege of Dentistry and Oral Surgery, Alasmarya of Dental Materials, Faculty of Dentistry, Sebha University, Sebha, LibyaDepartment of Conservative Dentistry, Faculty of Dentistry, University of Kufa, Najaf, IraqDepartment of Dental Materials, Faculty of Dentistry, Sebha University, Sebha, LibyaDepartment of Engineering, Manchester Metropolitan University, Manchester M1 5GD, UKPeracetic acid (PAA) is widely used as a sterilizing/disinfecting agent, and, in endodontics, it has been introduced as a promising irrigant in root canal treatment. It has been used at different concentrations to achieve various functions. However, endodontic instruments in contact with PAA of a certain concentration may affect their fatigue resistance. Therefore, the aim of this study was to investigate the impact of PAA on the cyclic fatigue resistance of three commercial heat-treated nickel-titanium (NiTi) rotary files. Three types of heat-treated NiTi rotary files were selected: One Curve (OC), ProTaper Gold (PTG), and Wave One Gold (WOG). Each type was divided into three subgroups (n = 6 for each file type): (1) untreated instruments; (2) files immersed in 0.002% PAA; and (3) files immersed in 0.35% PAA. The performance of each file type was tested in a simulated canal. The number of cycles to fracture (NCF) was determined to assess cyclic fatigue resistance of the files. Independent sample t-test was applied to compare each treated file within a subgroup with its respective control group, and one-way ANOVA was used for comparison among the main groups. All types of tested files revealed a significant decline in the cyclic fatigue resistance after exposure to 0.002% PAA except the PTG (P=0.209). After exposure of the files to a higher concentration (0.35% PAA), a dramatic reduction was demonstrated by all the groups. Before and after exposure of the files to PAA, PTG displayed the highest cyclic fatigue resistance, followed by the WOG, while the OC showed the lowest resistance. Exposure of heated-treated NiTi files to PAA in a relatively high or low concentration adversely affects the cyclic fatigue resistance. The PTG files demonstrated the best performance among the tested types and can be disinfected with 0.002% PAA for clinical purpose.http://dx.doi.org/10.1155/2021/6676005 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Suhad Jabbar Hamed Al-Nasrawi Zuha Ayad Jaber Nibrass Talib Al-Quraine Abtesam Imhemed Aljdaimi Sattar Jabbar Abdul-Zahra Al-Hmedat Saleh Zidan Julfikar Haider |
spellingShingle |
Suhad Jabbar Hamed Al-Nasrawi Zuha Ayad Jaber Nibrass Talib Al-Quraine Abtesam Imhemed Aljdaimi Sattar Jabbar Abdul-Zahra Al-Hmedat Saleh Zidan Julfikar Haider Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument International Journal of Dentistry |
author_facet |
Suhad Jabbar Hamed Al-Nasrawi Zuha Ayad Jaber Nibrass Talib Al-Quraine Abtesam Imhemed Aljdaimi Sattar Jabbar Abdul-Zahra Al-Hmedat Saleh Zidan Julfikar Haider |
author_sort |
Suhad Jabbar Hamed Al-Nasrawi |
title |
Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument |
title_short |
Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument |
title_full |
Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument |
title_fullStr |
Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument |
title_full_unstemmed |
Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument |
title_sort |
impact of peracetic acid on the dynamic cyclic fatigue of heat-treated nickel-titanium rotary endodontic instrument |
publisher |
Hindawi Limited |
series |
International Journal of Dentistry |
issn |
1687-8728 1687-8736 |
publishDate |
2021-01-01 |
description |
Peracetic acid (PAA) is widely used as a sterilizing/disinfecting agent, and, in endodontics, it has been introduced as a promising irrigant in root canal treatment. It has been used at different concentrations to achieve various functions. However, endodontic instruments in contact with PAA of a certain concentration may affect their fatigue resistance. Therefore, the aim of this study was to investigate the impact of PAA on the cyclic fatigue resistance of three commercial heat-treated nickel-titanium (NiTi) rotary files. Three types of heat-treated NiTi rotary files were selected: One Curve (OC), ProTaper Gold (PTG), and Wave One Gold (WOG). Each type was divided into three subgroups (n = 6 for each file type): (1) untreated instruments; (2) files immersed in 0.002% PAA; and (3) files immersed in 0.35% PAA. The performance of each file type was tested in a simulated canal. The number of cycles to fracture (NCF) was determined to assess cyclic fatigue resistance of the files. Independent sample t-test was applied to compare each treated file within a subgroup with its respective control group, and one-way ANOVA was used for comparison among the main groups. All types of tested files revealed a significant decline in the cyclic fatigue resistance after exposure to 0.002% PAA except the PTG (P=0.209). After exposure of the files to a higher concentration (0.35% PAA), a dramatic reduction was demonstrated by all the groups. Before and after exposure of the files to PAA, PTG displayed the highest cyclic fatigue resistance, followed by the WOG, while the OC showed the lowest resistance. Exposure of heated-treated NiTi files to PAA in a relatively high or low concentration adversely affects the cyclic fatigue resistance. The PTG files demonstrated the best performance among the tested types and can be disinfected with 0.002% PAA for clinical purpose. |
url |
http://dx.doi.org/10.1155/2021/6676005 |
work_keys_str_mv |
AT suhadjabbarhamedalnasrawi impactofperaceticacidonthedynamiccyclicfatigueofheattreatednickeltitaniumrotaryendodonticinstrument AT zuhaayadjaber impactofperaceticacidonthedynamiccyclicfatigueofheattreatednickeltitaniumrotaryendodonticinstrument AT nibrasstalibalquraine impactofperaceticacidonthedynamiccyclicfatigueofheattreatednickeltitaniumrotaryendodonticinstrument AT abtesamimhemedaljdaimi impactofperaceticacidonthedynamiccyclicfatigueofheattreatednickeltitaniumrotaryendodonticinstrument AT sattarjabbarabdulzahraalhmedat impactofperaceticacidonthedynamiccyclicfatigueofheattreatednickeltitaniumrotaryendodonticinstrument AT salehzidan impactofperaceticacidonthedynamiccyclicfatigueofheattreatednickeltitaniumrotaryendodonticinstrument AT julfikarhaider impactofperaceticacidonthedynamiccyclicfatigueofheattreatednickeltitaniumrotaryendodonticinstrument |
_version_ |
1714866667345936384 |