Dataset on the performance of a three phase induction motor under balanced and unbalanced supply voltage conditions

Three phase induction motors (TPIM) are extensively used for various applications in the industry for driving cranes, hoists, lifts, rolling mills, cooling fans, textile operations, and so forth. TPIM are designed to operate on balanced three phase power supply, but sometimes three phase supply line...

Full description

Bibliographic Details
Main Authors: Aderibigbe Israel Adekitan, Isaac Samuel, Elizabeth Amuta
Format: Article
Language:English
Published: Elsevier 2019-06-01
Series:Data in Brief
Online Access:http://www.sciencedirect.com/science/article/pii/S2352340919302987
id doaj-bb741141954f48ddb012a78c09477db2
record_format Article
spelling doaj-bb741141954f48ddb012a78c09477db22020-11-25T02:15:01ZengElsevierData in Brief2352-34092019-06-0124Dataset on the performance of a three phase induction motor under balanced and unbalanced supply voltage conditionsAderibigbe Israel Adekitan0Isaac Samuel1Elizabeth Amuta2Corresponding author.; Department of Electrical and Information Engineering, Covenant University, Ota, NigeriaDepartment of Electrical and Information Engineering, Covenant University, Ota, NigeriaDepartment of Electrical and Information Engineering, Covenant University, Ota, NigeriaThree phase induction motors (TPIM) are extensively used for various applications in the industry for driving cranes, hoists, lifts, rolling mills, cooling fans, textile operations, and so forth. TPIM are designed to operate on balanced three phase power supply, but sometimes three phase supply line voltages to which the TPIM is connected may be unbalanced. In this data article, the operational data of a TPIM operating under changing voltage scenarios is profiled to determine the variations in the magnitude of the operational parameters of the motor. The magnitude of each of the line voltages was separately varied from the balanced state (0% unbalance) until 5% voltage unbalance condition was achieved, in line with the recommendations and guidelines of the National Electrical Manufactures Association. The motor parameters; both mechanical and electrical, at various slip values were collected in six sets for the 0%, 1%, 2%, 3%, 4%, and 5% unbalance voltage conditions. Frequency distributions and statistical analysis were carried out to identify the data pattern and data variation trends among the parameters in the dataset. Keywords: Motor performance characteristics, Power quality, Three phase induction motor, Positive and negative sequence component, Voltage unbalancehttp://www.sciencedirect.com/science/article/pii/S2352340919302987
collection DOAJ
language English
format Article
sources DOAJ
author Aderibigbe Israel Adekitan
Isaac Samuel
Elizabeth Amuta
spellingShingle Aderibigbe Israel Adekitan
Isaac Samuel
Elizabeth Amuta
Dataset on the performance of a three phase induction motor under balanced and unbalanced supply voltage conditions
Data in Brief
author_facet Aderibigbe Israel Adekitan
Isaac Samuel
Elizabeth Amuta
author_sort Aderibigbe Israel Adekitan
title Dataset on the performance of a three phase induction motor under balanced and unbalanced supply voltage conditions
title_short Dataset on the performance of a three phase induction motor under balanced and unbalanced supply voltage conditions
title_full Dataset on the performance of a three phase induction motor under balanced and unbalanced supply voltage conditions
title_fullStr Dataset on the performance of a three phase induction motor under balanced and unbalanced supply voltage conditions
title_full_unstemmed Dataset on the performance of a three phase induction motor under balanced and unbalanced supply voltage conditions
title_sort dataset on the performance of a three phase induction motor under balanced and unbalanced supply voltage conditions
publisher Elsevier
series Data in Brief
issn 2352-3409
publishDate 2019-06-01
description Three phase induction motors (TPIM) are extensively used for various applications in the industry for driving cranes, hoists, lifts, rolling mills, cooling fans, textile operations, and so forth. TPIM are designed to operate on balanced three phase power supply, but sometimes three phase supply line voltages to which the TPIM is connected may be unbalanced. In this data article, the operational data of a TPIM operating under changing voltage scenarios is profiled to determine the variations in the magnitude of the operational parameters of the motor. The magnitude of each of the line voltages was separately varied from the balanced state (0% unbalance) until 5% voltage unbalance condition was achieved, in line with the recommendations and guidelines of the National Electrical Manufactures Association. The motor parameters; both mechanical and electrical, at various slip values were collected in six sets for the 0%, 1%, 2%, 3%, 4%, and 5% unbalance voltage conditions. Frequency distributions and statistical analysis were carried out to identify the data pattern and data variation trends among the parameters in the dataset. Keywords: Motor performance characteristics, Power quality, Three phase induction motor, Positive and negative sequence component, Voltage unbalance
url http://www.sciencedirect.com/science/article/pii/S2352340919302987
work_keys_str_mv AT aderibigbeisraeladekitan datasetontheperformanceofathreephaseinductionmotorunderbalancedandunbalancedsupplyvoltageconditions
AT isaacsamuel datasetontheperformanceofathreephaseinductionmotorunderbalancedandunbalancedsupplyvoltageconditions
AT elizabethamuta datasetontheperformanceofathreephaseinductionmotorunderbalancedandunbalancedsupplyvoltageconditions
_version_ 1724898386182668288