INDOOR LIGHT ENVIRONMENT INSIDE RESIDENTIAL BUILDINGS IN THE EVENT OF APPLICATION OF COMBINED METHODS OF SUN PROTECTION

The article deals with the problem of enhancing the light environment inside residential buildings by means of combined methods of sun protection in the hot and sunny climate of Lebanon. The proposed sunscreens are effective both if the insolation intensity goes up and down. For example, the light,...

Full description

Bibliographic Details
Main Authors: Stetskiy Sergey Vyacheslavovich, Khodeir Walid Abbas
Format: Article
Language:English
Published: Moscow State University of Civil Engineering (MGSU) 2012-10-01
Series:Vestnik MGSU
Subjects:
Online Access:http://vestnikmgsu.ru/files/archive/issues/2012/8/ru/6.pdf
id doaj-bb658d165ba6413b8c547bc16204e953
record_format Article
spelling doaj-bb658d165ba6413b8c547bc16204e9532020-11-24T22:04:52ZengMoscow State University of Civil Engineering (MGSU)Vestnik MGSU 1997-09352012-10-0183945INDOOR LIGHT ENVIRONMENT INSIDE RESIDENTIAL BUILDINGS IN THE EVENT OF APPLICATION OF COMBINED METHODS OF SUN PROTECTIONStetskiy Sergey Vyacheslavovich0Khodeir Walid Abbas1Moscow State University of Civil Engineering (MSUCE)Moscow State University of Civil Engineering (MSUCE)The article deals with the problem of enhancing the light environment inside residential buildings by means of combined methods of sun protection in the hot and sunny climate of Lebanon. The proposed sunscreens are effective both if the insolation intensity goes up and down. For example, the light, refl ected by the sun protection unit located below the storey in question, brings more natural light into those sections of rooms that are located further from the window, so the illumination factor in these areas is substantially increased. However, the aforementioned pattern of natural light design is effi cient in the clear sky environment of the sunny climate, which differs a lot from the standard conditions of the grey sky. On top of the above, the new approach to the identifi cation of the T4 factor value is proposed. This factor describes the impact produced by the sunscreen in the clear sky environment. In this case, its value shall not be taken as constant. Theoretical and practical research was completed to identify the role of sun protection devices (sunscreens) in the course of natural (passive) regulation of the light environment inside buildings. The principal item of research was the condition of the illumination environment inside the premises under consideration. The research was performed inside a residential building located in a new district of Beirut, the capital of Lebanon. The research comprised several stages, including theoretical and fi eld researches of the light environment inside the premises under consideration in the aftermath of installation of sunscreens.http://vestnikmgsu.ru/files/archive/issues/2012/8/ru/6.pdflight environmentdaylight factorsunscreens"clear sky" method
collection DOAJ
language English
format Article
sources DOAJ
author Stetskiy Sergey Vyacheslavovich
Khodeir Walid Abbas
spellingShingle Stetskiy Sergey Vyacheslavovich
Khodeir Walid Abbas
INDOOR LIGHT ENVIRONMENT INSIDE RESIDENTIAL BUILDINGS IN THE EVENT OF APPLICATION OF COMBINED METHODS OF SUN PROTECTION
Vestnik MGSU
light environment
daylight factor
sunscreens
"clear sky" method
author_facet Stetskiy Sergey Vyacheslavovich
Khodeir Walid Abbas
author_sort Stetskiy Sergey Vyacheslavovich
title INDOOR LIGHT ENVIRONMENT INSIDE RESIDENTIAL BUILDINGS IN THE EVENT OF APPLICATION OF COMBINED METHODS OF SUN PROTECTION
title_short INDOOR LIGHT ENVIRONMENT INSIDE RESIDENTIAL BUILDINGS IN THE EVENT OF APPLICATION OF COMBINED METHODS OF SUN PROTECTION
title_full INDOOR LIGHT ENVIRONMENT INSIDE RESIDENTIAL BUILDINGS IN THE EVENT OF APPLICATION OF COMBINED METHODS OF SUN PROTECTION
title_fullStr INDOOR LIGHT ENVIRONMENT INSIDE RESIDENTIAL BUILDINGS IN THE EVENT OF APPLICATION OF COMBINED METHODS OF SUN PROTECTION
title_full_unstemmed INDOOR LIGHT ENVIRONMENT INSIDE RESIDENTIAL BUILDINGS IN THE EVENT OF APPLICATION OF COMBINED METHODS OF SUN PROTECTION
title_sort indoor light environment inside residential buildings in the event of application of combined methods of sun protection
publisher Moscow State University of Civil Engineering (MGSU)
series Vestnik MGSU
issn 1997-0935
publishDate 2012-10-01
description The article deals with the problem of enhancing the light environment inside residential buildings by means of combined methods of sun protection in the hot and sunny climate of Lebanon. The proposed sunscreens are effective both if the insolation intensity goes up and down. For example, the light, refl ected by the sun protection unit located below the storey in question, brings more natural light into those sections of rooms that are located further from the window, so the illumination factor in these areas is substantially increased. However, the aforementioned pattern of natural light design is effi cient in the clear sky environment of the sunny climate, which differs a lot from the standard conditions of the grey sky. On top of the above, the new approach to the identifi cation of the T4 factor value is proposed. This factor describes the impact produced by the sunscreen in the clear sky environment. In this case, its value shall not be taken as constant. Theoretical and practical research was completed to identify the role of sun protection devices (sunscreens) in the course of natural (passive) regulation of the light environment inside buildings. The principal item of research was the condition of the illumination environment inside the premises under consideration. The research was performed inside a residential building located in a new district of Beirut, the capital of Lebanon. The research comprised several stages, including theoretical and fi eld researches of the light environment inside the premises under consideration in the aftermath of installation of sunscreens.
topic light environment
daylight factor
sunscreens
"clear sky" method
url http://vestnikmgsu.ru/files/archive/issues/2012/8/ru/6.pdf
work_keys_str_mv AT stetskiysergeyvyacheslavovich indoorlightenvironmentinsideresidentialbuildingsintheeventofapplicationofcombinedmethodsofsunprotection
AT khodeirwalidabbas indoorlightenvironmentinsideresidentialbuildingsintheeventofapplicationofcombinedmethodsofsunprotection
_version_ 1725828399035842560