High Dynamic Range Particle Image Velocimetry Applied to Heat Convection Studies
Convective heat transfer occurs in a wide range of engineering applications, from nuclear reactors to portable electronic devices. Accurate whole-field turbulence and flow measurements are crucial to understanding convective heat transfer in complex flow fields, thereby enabling optimal design of t...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2014-03-01
|
Series: | EPJ Web of Conferences |
Online Access: | http://dx.doi.org/10.1051/epjconf/20146701001 |
id |
doaj-bb49511d33e44f7892a8331cfde8d211 |
---|---|
record_format |
Article |
spelling |
doaj-bb49511d33e44f7892a8331cfde8d2112021-08-02T11:24:47ZengEDP SciencesEPJ Web of Conferences2100-014X2014-03-01670100110.1051/epjconf/20146701001epjconf_efm-13_01001High Dynamic Range Particle Image Velocimetry Applied to Heat Convection StudiesPersoons Tim0Department of Mechanical & Manufacturing Engineering, Parsons Building, Trinity College, Dublin 2 Convective heat transfer occurs in a wide range of engineering applications, from nuclear reactors to portable electronic devices. Accurate whole-field turbulence and flow measurements are crucial to understanding convective heat transfer in complex flow fields, thereby enabling optimal design of these devices. Particle image velocimetry (PIV) is the preferred whole-field flow measurement technique. However in many configurations the dynamic velocity range of conventional PIV is too limited to accurately resolve both high mean velocities and turbulence intensities in lower velocity regions. This paper employs high dynamic range (HDR) PIV with an advanced acquisition and processing technique based on multiple pulse separation (MPS) double-frame imaging. The methodology uses a conventional adaptive multi-grid algorithm for vector evaluation, and determines the optimal pulse separation in space and time in a post-processing routine. Two test cases are discussed: For an impinging synthetic jet flow (Case I), HDR PIV increases the dynamic velocity range 25-fold compared to conventional PIV. For an oscillatory buoyant plume from a pair of horizontal heated cylinders (Case II), the dynamic velocity range is increased 5.5 times. This technique has yielded new insights in synthetic jet heat transfer by correlating local surface heat transfer rates to near-wall turbulence intensity in a single whole-field measurement. http://dx.doi.org/10.1051/epjconf/20146701001 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Persoons Tim |
spellingShingle |
Persoons Tim High Dynamic Range Particle Image Velocimetry Applied to Heat Convection Studies EPJ Web of Conferences |
author_facet |
Persoons Tim |
author_sort |
Persoons Tim |
title |
High Dynamic Range Particle Image Velocimetry Applied to Heat Convection Studies |
title_short |
High Dynamic Range Particle Image Velocimetry Applied to Heat Convection Studies |
title_full |
High Dynamic Range Particle Image Velocimetry Applied to Heat Convection Studies |
title_fullStr |
High Dynamic Range Particle Image Velocimetry Applied to Heat Convection Studies |
title_full_unstemmed |
High Dynamic Range Particle Image Velocimetry Applied to Heat Convection Studies |
title_sort |
high dynamic range particle image velocimetry applied to heat convection studies |
publisher |
EDP Sciences |
series |
EPJ Web of Conferences |
issn |
2100-014X |
publishDate |
2014-03-01 |
description |
Convective heat transfer occurs in a wide range of engineering applications, from nuclear reactors to portable electronic devices. Accurate whole-field turbulence and flow measurements are crucial to understanding convective heat transfer in complex flow fields, thereby enabling optimal design of these devices. Particle image velocimetry (PIV) is the preferred whole-field flow measurement technique. However in many configurations the dynamic velocity range of conventional PIV is too limited to accurately resolve both high mean velocities and turbulence intensities in lower velocity regions. This paper employs high dynamic range (HDR) PIV with an advanced acquisition and processing technique based on multiple pulse separation (MPS) double-frame imaging. The methodology uses a conventional adaptive multi-grid algorithm for vector evaluation, and determines the optimal pulse separation in space and time in a post-processing routine. Two test cases are discussed: For an impinging synthetic jet flow (Case I), HDR PIV increases the dynamic velocity range 25-fold compared to conventional PIV. For an oscillatory buoyant plume from a pair of horizontal heated cylinders (Case II), the dynamic velocity range is increased 5.5 times. This technique has yielded new insights in synthetic jet heat transfer by correlating local surface heat transfer rates to near-wall turbulence intensity in a single whole-field measurement.
|
url |
http://dx.doi.org/10.1051/epjconf/20146701001 |
work_keys_str_mv |
AT persoonstim highdynamicrangeparticleimagevelocimetryappliedtoheatconvectionstudies |
_version_ |
1721233245610180608 |