THE IMPACT OF ORTHOKERATOLOGIC CONTACT LENSES ON SPHERICAL ABERRATION OF THE OPTICAL SYSTEM OF THE EYE

The purpose of this study is to measure the spherical aberration (SA) of the cornea and the optical system of the eye before and after wearing orthokeratologic (OK) contact lenses. Material and methods. 22 patients (44 eyes) with myopia aged 11 to 18 years were examined. The total SA was determined...

Full description

Bibliographic Details
Main Authors: E. P. Tarutta, S. G. Harutyunyan
Format: Article
Language:Russian
Published: Real Time Ltd 2018-10-01
Series:Российский офтальмологический журнал
Subjects:
Online Access:https://roj.igb.ru/jour/article/view/149
id doaj-bacd9f0d67794eb2a3d5ed4c8c83d5ec
record_format Article
spelling doaj-bacd9f0d67794eb2a3d5ed4c8c83d5ec2021-07-28T13:01:39ZrusReal Time LtdРоссийский офтальмологический журнал2072-00762587-57602018-10-01112172110.21516/2072-0076-2018-11-2-17-21149THE IMPACT OF ORTHOKERATOLOGIC CONTACT LENSES ON SPHERICAL ABERRATION OF THE OPTICAL SYSTEM OF THE EYEE. P. Tarutta0S. G. Harutyunyan1Moscow Helmholtz Research Institute of Eye DiseasesMoscow Helmholtz Research Institute of Eye DiseasesThe purpose of this study is to measure the spherical aberration (SA) of the cornea and the optical system of the eye before and after wearing orthokeratologic (OK) contact lenses. Material and methods. 22 patients (44 eyes) with myopia aged 11 to 18 years were examined. The total SA was determined after medical cycloplegia performed on OPD-Scan III aberrometer, Nidek. To analyze SA values before and after wearing OK lenses, we chose pupil areas from 3 mm to 7.5 mm in 0.5-1 mm increments. Results. In intact eyes with myopia, the total SA is mildly positive and is growing with the increase of the pupil diameter. After OK correction, the SA is changing: from 3 to 6 mm of the pupillary area, the positive SA increases by 50-130 %, in the 6.3 mm area it falls sharply and becomes negative, growing on the way to the periphery of the pupillary area. Conclusions. Corneal topography changes after OK corrections lead to specific changes of the wavefront of myopic eyes, causing increased visual performance and eliminating the hyperopic defocus at retinal periphery. For citation: Tarutta E.P., Harutyunyan S.G. The impact of orthokeratologic contact lenses on spherical aberration of the optical system of the eye. Russian ophthalmological journal. 2018; 11 (2): 17-21. doi: 10.21516/2072-0076-2018-11-2-17-21 (In Russian).https://roj.igb.ru/jour/article/view/149сферическая аберрацияортокератологиямиопияspherical aberrationorthokeratologymyopia
collection DOAJ
language Russian
format Article
sources DOAJ
author E. P. Tarutta
S. G. Harutyunyan
spellingShingle E. P. Tarutta
S. G. Harutyunyan
THE IMPACT OF ORTHOKERATOLOGIC CONTACT LENSES ON SPHERICAL ABERRATION OF THE OPTICAL SYSTEM OF THE EYE
Российский офтальмологический журнал
сферическая аберрация
ортокератология
миопия
spherical aberration
orthokeratology
myopia
author_facet E. P. Tarutta
S. G. Harutyunyan
author_sort E. P. Tarutta
title THE IMPACT OF ORTHOKERATOLOGIC CONTACT LENSES ON SPHERICAL ABERRATION OF THE OPTICAL SYSTEM OF THE EYE
title_short THE IMPACT OF ORTHOKERATOLOGIC CONTACT LENSES ON SPHERICAL ABERRATION OF THE OPTICAL SYSTEM OF THE EYE
title_full THE IMPACT OF ORTHOKERATOLOGIC CONTACT LENSES ON SPHERICAL ABERRATION OF THE OPTICAL SYSTEM OF THE EYE
title_fullStr THE IMPACT OF ORTHOKERATOLOGIC CONTACT LENSES ON SPHERICAL ABERRATION OF THE OPTICAL SYSTEM OF THE EYE
title_full_unstemmed THE IMPACT OF ORTHOKERATOLOGIC CONTACT LENSES ON SPHERICAL ABERRATION OF THE OPTICAL SYSTEM OF THE EYE
title_sort impact of orthokeratologic contact lenses on spherical aberration of the optical system of the eye
publisher Real Time Ltd
series Российский офтальмологический журнал
issn 2072-0076
2587-5760
publishDate 2018-10-01
description The purpose of this study is to measure the spherical aberration (SA) of the cornea and the optical system of the eye before and after wearing orthokeratologic (OK) contact lenses. Material and methods. 22 patients (44 eyes) with myopia aged 11 to 18 years were examined. The total SA was determined after medical cycloplegia performed on OPD-Scan III aberrometer, Nidek. To analyze SA values before and after wearing OK lenses, we chose pupil areas from 3 mm to 7.5 mm in 0.5-1 mm increments. Results. In intact eyes with myopia, the total SA is mildly positive and is growing with the increase of the pupil diameter. After OK correction, the SA is changing: from 3 to 6 mm of the pupillary area, the positive SA increases by 50-130 %, in the 6.3 mm area it falls sharply and becomes negative, growing on the way to the periphery of the pupillary area. Conclusions. Corneal topography changes after OK corrections lead to specific changes of the wavefront of myopic eyes, causing increased visual performance and eliminating the hyperopic defocus at retinal periphery. For citation: Tarutta E.P., Harutyunyan S.G. The impact of orthokeratologic contact lenses on spherical aberration of the optical system of the eye. Russian ophthalmological journal. 2018; 11 (2): 17-21. doi: 10.21516/2072-0076-2018-11-2-17-21 (In Russian).
topic сферическая аберрация
ортокератология
миопия
spherical aberration
orthokeratology
myopia
url https://roj.igb.ru/jour/article/view/149
work_keys_str_mv AT eptarutta theimpactoforthokeratologiccontactlensesonsphericalaberrationoftheopticalsystemoftheeye
AT sgharutyunyan theimpactoforthokeratologiccontactlensesonsphericalaberrationoftheopticalsystemoftheeye
AT eptarutta impactoforthokeratologiccontactlensesonsphericalaberrationoftheopticalsystemoftheeye
AT sgharutyunyan impactoforthokeratologiccontactlensesonsphericalaberrationoftheopticalsystemoftheeye
_version_ 1721277244769304576