Effect Of Value Of Resistance Announcement To Thd In Electrical System Faculty Of Engineering University Udayana Denpasar
AC (Air Conditioner), TV, lamp, LCD and others are categorized as nonlinear load generating harmonics. The high content of harmonics has a negative impact on the quality of electrical power. The result of measurement of THD (Total Harmonic Distortion) current at 9 ohm ground resistance value at phas...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Udayana
2018-02-01
|
Series: | Journal of Electrical, Electronics and Informatics |
Online Access: | https://ojs.unud.ac.id/index.php/JEEI/article/view/40658 |
id |
doaj-baa6687f157d4aba8155ef11d6815752 |
---|---|
record_format |
Article |
spelling |
doaj-baa6687f157d4aba8155ef11d68157522020-11-25T02:42:04ZengUniversitas UdayanaJournal of Electrical, Electronics and Informatics2549-83042622-03932018-02-0121212410.24843/JEEI.2018.v02.i01.p0540658Effect Of Value Of Resistance Announcement To Thd In Electrical System Faculty Of Engineering University Udayana DenpasarI. G. N. Janardana0I W Arta Wijaya1I. N. Karnata Mataram2Electrical Engineering Department, Faculty of Engineering, Udayana University, Bukit Jimbaran, IndonesiaElectrical Engineering Department, Faculty of Engineering, Udayana University, Bukit Jimbaran, IndonesianCivil Engineering Department, Faculty of Engineering, Udayana University, Bukit Jimbaran, IndonesiaAC (Air Conditioner), TV, lamp, LCD and others are categorized as nonlinear load generating harmonics. The high content of harmonics has a negative impact on the quality of electrical power. The result of measurement of THD (Total Harmonic Distortion) current at 9 ohm ground resistance value at phase R = 9,8%, phase S = 11,0%, phase T = 7,5% exceed from standard value IEEE 519 Year 2014 equal to ? 5 , 0%, THD measurement of phase voltage R = 1.4%, phase S = 1.2%, phase T = 1.3%, meet the maximum THDv standard of ? 5%. To overcome this problem, it was observed the effect of the value of ground resistance to THDi and THDv on the electrical system of the College of Engineering Faculty of Denpasar. This method of analysis with ETAP software simulation. With grounding system ? 3 ohm only effect on current THD only with decreasing value of THDi become: phasa R = 4,2%, phase S = 5% and phase T = 4,3%, meaning with grounding system ? 3 ohm THD current fulfill IEEE 519 - 2014 standard <5%. while THD voltage has no effect (THD value of fixed voltage). Several studies have suggested that THD repair can be done by filter installation. However in this study the installation of grounding system ? 3 ohms can reduce the value of current THD.https://ojs.unud.ac.id/index.php/JEEI/article/view/40658 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
I. G. N. Janardana I W Arta Wijaya I. N. Karnata Mataram |
spellingShingle |
I. G. N. Janardana I W Arta Wijaya I. N. Karnata Mataram Effect Of Value Of Resistance Announcement To Thd In Electrical System Faculty Of Engineering University Udayana Denpasar Journal of Electrical, Electronics and Informatics |
author_facet |
I. G. N. Janardana I W Arta Wijaya I. N. Karnata Mataram |
author_sort |
I. G. N. Janardana |
title |
Effect Of Value Of Resistance Announcement To Thd In Electrical System Faculty Of Engineering University Udayana Denpasar |
title_short |
Effect Of Value Of Resistance Announcement To Thd In Electrical System Faculty Of Engineering University Udayana Denpasar |
title_full |
Effect Of Value Of Resistance Announcement To Thd In Electrical System Faculty Of Engineering University Udayana Denpasar |
title_fullStr |
Effect Of Value Of Resistance Announcement To Thd In Electrical System Faculty Of Engineering University Udayana Denpasar |
title_full_unstemmed |
Effect Of Value Of Resistance Announcement To Thd In Electrical System Faculty Of Engineering University Udayana Denpasar |
title_sort |
effect of value of resistance announcement to thd in electrical system faculty of engineering university udayana denpasar |
publisher |
Universitas Udayana |
series |
Journal of Electrical, Electronics and Informatics |
issn |
2549-8304 2622-0393 |
publishDate |
2018-02-01 |
description |
AC (Air Conditioner), TV, lamp, LCD and others are categorized as nonlinear load generating harmonics. The high content of harmonics has a negative impact on the quality of electrical power. The result of measurement of THD (Total Harmonic Distortion) current at 9 ohm ground resistance value at phase R = 9,8%, phase S = 11,0%, phase T = 7,5% exceed from standard value IEEE 519 Year 2014 equal to ? 5 , 0%, THD measurement of phase voltage R = 1.4%, phase S = 1.2%, phase T = 1.3%, meet the maximum THDv standard of ? 5%. To overcome this problem, it was observed the effect of the value of ground resistance to THDi and THDv on the electrical system of the College of Engineering Faculty of Denpasar. This method of analysis with ETAP software simulation. With grounding system ? 3 ohm only effect on current THD only with decreasing value of THDi become: phasa R = 4,2%, phase S = 5% and phase T = 4,3%, meaning with grounding system ? 3 ohm THD current fulfill IEEE 519 - 2014 standard <5%. while THD voltage has no effect (THD value of fixed voltage). Several studies have suggested that THD repair can be done by filter installation. However in this study the installation of grounding system ? 3 ohms can reduce the value of current THD. |
url |
https://ojs.unud.ac.id/index.php/JEEI/article/view/40658 |
work_keys_str_mv |
AT ignjanardana effectofvalueofresistanceannouncementtothdinelectricalsystemfacultyofengineeringuniversityudayanadenpasar AT iwartawijaya effectofvalueofresistanceannouncementtothdinelectricalsystemfacultyofengineeringuniversityudayanadenpasar AT inkarnatamataram effectofvalueofresistanceannouncementtothdinelectricalsystemfacultyofengineeringuniversityudayanadenpasar |
_version_ |
1724775528932573184 |