Reaction of Rat Subcutaneous Connective Tissue to Resin Composites Polymerized with Different Light Curing Units and Different Lightening Methods

The aim of the study was to determine and compare the reaction of rat subcutaneous connective tissue to resin composites polymerized with different lights curing and lightening methods. In this in vivo study, 20 mature Wister Albino rats were used. The composite discs, 4 mm in diameter and 2 mm thic...

Full description

Bibliographic Details
Main Authors: Atiyeh Feiz, Farahnaz Arbabzadeh Zavareh, Seyed Mohammad Razavi, Hamid Badrian, Sepideh Dolatyar, Mansoureh Vajihi
Format: Article
Language:English
Published: Hindawi Limited 2012-01-01
Series:International Journal of Dentistry
Online Access:http://dx.doi.org/10.1155/2012/156352
id doaj-ba2bd81bbfe944b4b72f68048fa09c43
record_format Article
spelling doaj-ba2bd81bbfe944b4b72f68048fa09c432020-11-24T23:13:54ZengHindawi LimitedInternational Journal of Dentistry1687-87281687-87362012-01-01201210.1155/2012/156352156352Reaction of Rat Subcutaneous Connective Tissue to Resin Composites Polymerized with Different Light Curing Units and Different Lightening MethodsAtiyeh Feiz0Farahnaz Arbabzadeh Zavareh1Seyed Mohammad Razavi2Hamid Badrian3Sepideh Dolatyar4Mansoureh Vajihi5Department of Operative Dentistry and Torabinejad Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan 81746-73461, IranDepartment of Operative Dentistry and Torabinejad Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan 81746-73461, IranDepartment of Oral Pathology and Torabinejad Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, IranSchool of Dentistry, Isfahan University of Medical Sciences, Isfahan, IranDepartment of Operative Dentistry and Torabinejad Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan 81746-73461, IranDepartment of Operative Dentistry and Torabinejad Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan 81746-73461, IranThe aim of the study was to determine and compare the reaction of rat subcutaneous connective tissue to resin composites polymerized with different lights curing and lightening methods. In this in vivo study, 20 mature Wister Albino rats were used. The composite discs, 4 mm in diameter and 2 mm thick, were cured by QTH or LED light curing units with 4 different lightning methods (full power QTH, full power LED, pulse LED, and ramp LED). Five resin composite discs were implanted in each rat, so that 4 of 5 discs for implantation of cured composite discs differently and central one as control without implantation. After sacrificing at 7, 14, 30, and 60 days the inflammatory grade, fibrosis, and necrosis were determined. Freedman and Cochran tests were used to analyze the data using SPSS software ver. 15. The results of the study showed significant differences in inflammation grade and fibrosis among control group and 4 experimental groups at day 14 (P<0.05). In necrosis, there was no significant difference among 4 groups in different times (P>0.05). In conclusion, neither the type of light curing units (LED or QTH) nor the lightening methods can affect the grade of inflammatory reaction.http://dx.doi.org/10.1155/2012/156352
collection DOAJ
language English
format Article
sources DOAJ
author Atiyeh Feiz
Farahnaz Arbabzadeh Zavareh
Seyed Mohammad Razavi
Hamid Badrian
Sepideh Dolatyar
Mansoureh Vajihi
spellingShingle Atiyeh Feiz
Farahnaz Arbabzadeh Zavareh
Seyed Mohammad Razavi
Hamid Badrian
Sepideh Dolatyar
Mansoureh Vajihi
Reaction of Rat Subcutaneous Connective Tissue to Resin Composites Polymerized with Different Light Curing Units and Different Lightening Methods
International Journal of Dentistry
author_facet Atiyeh Feiz
Farahnaz Arbabzadeh Zavareh
Seyed Mohammad Razavi
Hamid Badrian
Sepideh Dolatyar
Mansoureh Vajihi
author_sort Atiyeh Feiz
title Reaction of Rat Subcutaneous Connective Tissue to Resin Composites Polymerized with Different Light Curing Units and Different Lightening Methods
title_short Reaction of Rat Subcutaneous Connective Tissue to Resin Composites Polymerized with Different Light Curing Units and Different Lightening Methods
title_full Reaction of Rat Subcutaneous Connective Tissue to Resin Composites Polymerized with Different Light Curing Units and Different Lightening Methods
title_fullStr Reaction of Rat Subcutaneous Connective Tissue to Resin Composites Polymerized with Different Light Curing Units and Different Lightening Methods
title_full_unstemmed Reaction of Rat Subcutaneous Connective Tissue to Resin Composites Polymerized with Different Light Curing Units and Different Lightening Methods
title_sort reaction of rat subcutaneous connective tissue to resin composites polymerized with different light curing units and different lightening methods
publisher Hindawi Limited
series International Journal of Dentistry
issn 1687-8728
1687-8736
publishDate 2012-01-01
description The aim of the study was to determine and compare the reaction of rat subcutaneous connective tissue to resin composites polymerized with different lights curing and lightening methods. In this in vivo study, 20 mature Wister Albino rats were used. The composite discs, 4 mm in diameter and 2 mm thick, were cured by QTH or LED light curing units with 4 different lightning methods (full power QTH, full power LED, pulse LED, and ramp LED). Five resin composite discs were implanted in each rat, so that 4 of 5 discs for implantation of cured composite discs differently and central one as control without implantation. After sacrificing at 7, 14, 30, and 60 days the inflammatory grade, fibrosis, and necrosis were determined. Freedman and Cochran tests were used to analyze the data using SPSS software ver. 15. The results of the study showed significant differences in inflammation grade and fibrosis among control group and 4 experimental groups at day 14 (P<0.05). In necrosis, there was no significant difference among 4 groups in different times (P>0.05). In conclusion, neither the type of light curing units (LED or QTH) nor the lightening methods can affect the grade of inflammatory reaction.
url http://dx.doi.org/10.1155/2012/156352
work_keys_str_mv AT atiyehfeiz reactionofratsubcutaneousconnectivetissuetoresincompositespolymerizedwithdifferentlightcuringunitsanddifferentlighteningmethods
AT farahnazarbabzadehzavareh reactionofratsubcutaneousconnectivetissuetoresincompositespolymerizedwithdifferentlightcuringunitsanddifferentlighteningmethods
AT seyedmohammadrazavi reactionofratsubcutaneousconnectivetissuetoresincompositespolymerizedwithdifferentlightcuringunitsanddifferentlighteningmethods
AT hamidbadrian reactionofratsubcutaneousconnectivetissuetoresincompositespolymerizedwithdifferentlightcuringunitsanddifferentlighteningmethods
AT sepidehdolatyar reactionofratsubcutaneousconnectivetissuetoresincompositespolymerizedwithdifferentlightcuringunitsanddifferentlighteningmethods
AT mansourehvajihi reactionofratsubcutaneousconnectivetissuetoresincompositespolymerizedwithdifferentlightcuringunitsanddifferentlighteningmethods
_version_ 1725596179524222976