Design of linear capillary measuring transducers for low gas flow rates

The performed analysis of known capillary flowmeters for low gas flows reveals the prospect of constructing the primary measuring transducers of flowmeters with a linear output signal. Owing to the stability of dimensions of the pass-through channels in glass capillaries channels such flowmeters can...

Full description

Bibliographic Details
Main Authors: Zenoviy Teplukh, Ihor Dilay, Ivan Stasiuk, Myroslav Tykhan, Ivan-Roman Kubara
Format: Article
Language:English
Published: PC Technology Center 2018-12-01
Series:Eastern-European Journal of Enterprise Technologies
Subjects:
Online Access:http://journals.uran.ua/eejet/article/view/150526
id doaj-ba0f7e1d8b854a4ab4562b6b49fe4c15
record_format Article
spelling doaj-ba0f7e1d8b854a4ab4562b6b49fe4c152020-11-25T02:04:09ZengPC Technology CenterEastern-European Journal of Enterprise Technologies1729-37741729-40612018-12-0165 (96)253210.15587/1729-4061.2018.150526150526Design of linear capillary measuring transducers for low gas flow ratesZenoviy Teplukh0Ihor Dilay1Ivan Stasiuk2Myroslav Tykhan3Ivan-Roman Kubara4Lviv Polytechnic National University S. Bandery str., 12, Lviv, Ukraine, 79013Lviv Polytechnic National University S. Bandery str., 12, Lviv, Ukraine, 79013Lviv Polytechnic National University S. Bandery str., 12, Lviv, Ukraine, 79013Lviv Polytechnic National University S. Bandery str., 12, Lviv, Ukraine, 79013Lviv Polytechnic National University S. Bandery str., 12, Lviv, Ukraine, 79013The performed analysis of known capillary flowmeters for low gas flows reveals the prospect of constructing the primary measuring transducers of flowmeters with a linear output signal. Owing to the stability of dimensions of the pass-through channels in glass capillaries channels such flowmeters can demonstrate high metrological characteristics. In this regard, we have investigated the capillary as a sensing element in the primary transducers of flowmeters for low gas flows. Different circuits of capillary primary transducers for the measuring instruments of low gas flow rate have been examined. Our study makes it possible to select the optimal circuit of a primary measuring transducer based on the measurement range, as well as the number and size of the pass-through channels in capillaries. For example, the flow meter based on a package of capillaries demonstrates a wider measurement range compared to other schemes. We have derived analytical dependences that enable the design of single- capillary, package, and bridge transducers. Comparative characteristics of the specified primary measuring transducers are provided. We have constructed algorithms for calculating dimensions of channels in the capillaries of transducers with a linear output signal. The influence of temperature and barometric pressure on a deviation in the static characteristic of the transducer has been estimated. It was established that the bridge circuit, unlike others, ensures partial compensation for the influence of external factors. We have designed and investigated a capillary oxygen flowmeter, constructed using the bridge measurement circuit with a linear conversion function, intended for an automated system of the manufacturing process of workpieces for fiber light guides. The upper limit of measurement by the flowmeter is at the level of 54 l/h, its basic relative error is 0.8 %http://journals.uran.ua/eejet/article/view/150526capillary packagebridge capillary circuitlinearity of conversion functionlow gas flow rate
collection DOAJ
language English
format Article
sources DOAJ
author Zenoviy Teplukh
Ihor Dilay
Ivan Stasiuk
Myroslav Tykhan
Ivan-Roman Kubara
spellingShingle Zenoviy Teplukh
Ihor Dilay
Ivan Stasiuk
Myroslav Tykhan
Ivan-Roman Kubara
Design of linear capillary measuring transducers for low gas flow rates
Eastern-European Journal of Enterprise Technologies
capillary package
bridge capillary circuit
linearity of conversion function
low gas flow rate
author_facet Zenoviy Teplukh
Ihor Dilay
Ivan Stasiuk
Myroslav Tykhan
Ivan-Roman Kubara
author_sort Zenoviy Teplukh
title Design of linear capillary measuring transducers for low gas flow rates
title_short Design of linear capillary measuring transducers for low gas flow rates
title_full Design of linear capillary measuring transducers for low gas flow rates
title_fullStr Design of linear capillary measuring transducers for low gas flow rates
title_full_unstemmed Design of linear capillary measuring transducers for low gas flow rates
title_sort design of linear capillary measuring transducers for low gas flow rates
publisher PC Technology Center
series Eastern-European Journal of Enterprise Technologies
issn 1729-3774
1729-4061
publishDate 2018-12-01
description The performed analysis of known capillary flowmeters for low gas flows reveals the prospect of constructing the primary measuring transducers of flowmeters with a linear output signal. Owing to the stability of dimensions of the pass-through channels in glass capillaries channels such flowmeters can demonstrate high metrological characteristics. In this regard, we have investigated the capillary as a sensing element in the primary transducers of flowmeters for low gas flows. Different circuits of capillary primary transducers for the measuring instruments of low gas flow rate have been examined. Our study makes it possible to select the optimal circuit of a primary measuring transducer based on the measurement range, as well as the number and size of the pass-through channels in capillaries. For example, the flow meter based on a package of capillaries demonstrates a wider measurement range compared to other schemes. We have derived analytical dependences that enable the design of single- capillary, package, and bridge transducers. Comparative characteristics of the specified primary measuring transducers are provided. We have constructed algorithms for calculating dimensions of channels in the capillaries of transducers with a linear output signal. The influence of temperature and barometric pressure on a deviation in the static characteristic of the transducer has been estimated. It was established that the bridge circuit, unlike others, ensures partial compensation for the influence of external factors. We have designed and investigated a capillary oxygen flowmeter, constructed using the bridge measurement circuit with a linear conversion function, intended for an automated system of the manufacturing process of workpieces for fiber light guides. The upper limit of measurement by the flowmeter is at the level of 54 l/h, its basic relative error is 0.8 %
topic capillary package
bridge capillary circuit
linearity of conversion function
low gas flow rate
url http://journals.uran.ua/eejet/article/view/150526
work_keys_str_mv AT zenoviyteplukh designoflinearcapillarymeasuringtransducersforlowgasflowrates
AT ihordilay designoflinearcapillarymeasuringtransducersforlowgasflowrates
AT ivanstasiuk designoflinearcapillarymeasuringtransducersforlowgasflowrates
AT myroslavtykhan designoflinearcapillarymeasuringtransducersforlowgasflowrates
AT ivanromankubara designoflinearcapillarymeasuringtransducersforlowgasflowrates
_version_ 1724944310107897856